BURNDY
Compression
TWO HOLE HYLUG™
FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
TYPE YAZ-FX
UL LISTED 90° C,
600 VOLT TO 35 KV
x
ELECTRO-TIN
PLATED
CABLE
ACCOMMODATION
DIE AND COLOR
CODE INFORMATION
BEVELED
ENTRY
INSPECTION
WINDOW
CRIMPS
C-77
B
B
90°
T
B
T
L
T
45°
L
L
Fig. 1
Conductor
Catalog Number
YAZ8C2TC10FX
YAZ8C2TC10FX45
YAZ8C2TC10FX90
YAZ8C2TC10E2FX
YAZ8C2TC10E2FX45
YAZ8C2TC10E2FX90
YAZ8C2TC14E1FX
YAZ8C2TC14E1FX45
YAZ8C2TC14E1FX90
YAZ8C2TC14FX
YAZ8C2TC14FX45
YAZ8C2TC14FX90
YAZ8C2TC14E2FX
YAZ8C2TC14E2FX45
YAZ8C2TC14E2FX90
YAZ8C2TC38FX
YAZ8C2TC38FX45
YAZ8C2TC38FX90
YAZV6C2TC10E2FX
YAZV6C2TC10E2FX45
YAZV6C2TC10E2FX90
YAZV6C2TC14FX
YAZV6C2TC14FX45
YAZV6C2TC14FX90
YAZV6C2TC14E2FX
YAZV6C2TC14E2FX45
YAZV6C2TC14E2FX90
YAZV6C2TC14E1FX
YAZV6C2TC14E1FX45
YAZV6C2TC14E1FX90
YAZV6C2TC38FX
YAZV6C2TC38FX45
YAZV6C2TC38FX90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud Stud
Hole Hole Tongue
Size Spacing Width
# 10
5/8
.41
Figure
Dimensions
(B) (T)
(L)
2.20
.75 .08 2.09
1.37
2.33
.75 .08 2.22
1.50
2.70
.75 .08 2.60
1.87
2.32
.75 .08 2.20
1.
2.45
.75: .08 2.33
1.62
2.89
.75 .06 2.72
2.05
2.64
.75 .08 2.48
1.51
2.65
.75 .08 2.45
1.51
2.78
.75 .08 2.58
1.63
3.03
.75 .08 2.83
1.88
3.22
.75 .06 2.97
2.06
Dieless
(# of crimps)
Fig. 2
Fig. 3
Mechanical
MD6, OUR840
MD7-34R
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
# 10
37/24
#8 WELD
#3 AWG
**
10
1/4
3/4
.41
1/4
1
.44
5/8
.44
Y8MRB-1 (1)
W8CVT (2) W8CVT (2)
Y2MR (2)
W8CRT (2)) W8CRT (2)
MY29-11 (2)
X8CRT (2) X8CRT (2)
Y1MR (2)
U8CRT (2)
Red
49
1
1/4
3/4
.44
3/8
1
.58
# 10
3/4
.48
1/4
61/24
#6 WELD
#6 AWG
1/4
**
16
1/4
5/8
.48
3/4
.48
Y2MR (2)
W5CVT (2) W5CVT (2)
MY29-11 (2)
W5CRT (2) W5CRT (2)
Y644M (1)
X5CRT (2) X5CRT (2)
Y1MR (2)
U5CRT (2)
Blue
7
1-3/16
1
.48
3/8
1
.58
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** The MM
2
conductor size referenced here is for both Class 2 and Class 5 conductor.
*** The MM
2
conductor size listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX” connecotrs.
For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
TWO HOLE HYLUG™
FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(CONTINUED)
Conductor
Catalog Number
YAZV6C2TC38E2FX
YAZV6C2TC38E2FX-45
YAZV6C2TC38E2FX-90
YAZV6C2TC38E6FX
YAZV6C2TC38E6FX-45
YAZV6C2TC38E6FX-90
YAZV4C2TC38E2-FX
YAZV4C2TC38E2-FX-45
YAZV4C2TC38E2-FX-90
YAZV4C2TC38FX
YAZV4C2TC38FX45
YAZV4C2TC38FX90
YAZV4C2TC14FX
YAZV4C2TC14FX45
YAZV4C2TC14FX90
YAZV4C2TC14E2FX
YAZV4C2TC14E2FX45
YAZV4C2TC14E2FX90
YAZV2C2TC14FX
YAZV2C2TC14FX45
YAZV2C2TC14FX90
YAZV2C2TC14E2FX
YAZV2C2TC14E2FX45
YAZV2C2TC14E2FX90
YAZV2C2TC38FX
YAZV2C2TC38FX45
YAZV2C2TC38FX90
YAZV2C2NTCFX
YAZV2C2NTCFX45
YAZV2C2NTCFX90
YAZV1C2TC14FX
YAZV1C2TC14FX45
YAZV1C2TC14FX90
YAZV1C2TC14E1FX
YAZV1C2TC14E1FX45
YAZV1C2TC14E1FX90
YAZV1C2TC14E2FX
YAZV1C2TC14E2FX45
YAZV1C2TC14E2FX90
YAZV1C2TC38FX
YAZV1C2TC38FX45
YAZV1C2TC38FX90
YAZV1C2TC516E6FX
YAZV1C2TC516E6FX-45
YAZV1C2TC516E6FX-90
YAZV1C2TC516FX
YAZV1C2TC516FX45
YAZV1C2TC516FX90
Fig
***
#
AWG
MM
2
1
2
61/24
3
**
#6 WELD
1
16
#6 AWG
2
3
1
2
3
1
91/24-105/24
2
3
#4 WELD
-
1
2
#4 AWG
3
1
2
3
1
2
3
1
125/24-150/24
2
3
#2 WELD 35
1
2
#2 AWG
3
1
2
3
1
2
3
1
2
3
1
175/24-225/24
2
3
#1 WELD
-
1
2
#1 AWG
3
1
2
3
1
2
3
Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8
3/4
.58
Figure
Dimensions
(B) (T)
(L)
2.97
.75 .06 2.72
1.81
3.09
.75 .06 2.85
1.94
3.14
1.25 08 2.88
1.86
3.39
1.25 .08 3.13
2.11
2.83
1.25 .09 2.59
1.55
2.95
1.25 .09 2.72
1.68
3.01
1.38 .10 2.75
1.60
3.13
1.38 .10 2.87
1.73
3.57
1.38 .10 3.31
2.16
4.76
1.38 .10 4.50
3.35
3.04
1.38 .12 2.81
1.64
3.41
1.38 .12 3.18
2.01
3.16
1.38 .12 2.93
1.76
3.60
1.38 .12 3.37
2.20
3.35
1.38 .12 3.12
1.95
3.47
1.38 .12 3.24
2.08
Dieless
(# of crimps)
B
B
90°
T
B
T
L
T
45°
L
L
Fig. 1
Fig. 2
Fig. 3
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
W5CVT (2)
W5CRT (2)
X5CRT (2)
C-78
Mechanical
MD6, OUR840
MD7-34R
W5CVT (2)
W5CRT (2)
X5CRT (2)
3/8
7/8
.58
Y1MR (2)
Y2MR (2)
MY29-11 (2)
Y644M (1)
U5CRT (2)
Blue
7
1-3/16
3/8
3/4
.58
3/8
1
.58
1/4
5/8
.55
W4CVT (2)
W4CRT (2)
X4CRT (2)
W4CVT (2)
W4CRT (2)
X4CRT (2)
U4CRT (2)
Gray
8
1-5/16
1/4
3/4
.55
1/4
5/8
.68
Y1MR (4)
Y2MR (4)
MY29-11 (2)
Y644M (1)
1/4
3/4
.68
3/8
1
.68
W2CVT (2)
W2CRT (2)
X2CRT (2)
W2CVT (2)
W2CRT (2)
X2CRT (2)
U2CRT (2)
Brown
10
1-7/16
1/2
1-3/4
.83
1/4
5/8
.75
1/4
1
.75
1/4
3/4
.75
MY29-11 (2)
Y644M (1)
3/8
1
.75
W1CVT (2) W1CVT (2)
W1CRT-1 (2) W1CRT-1 (2)
X1CRT-1 (2) X1CRT-1 (2)
U1CRT-1 (2)
Green
11
1-7/16
5/16
7/8
.75
5/16
1
.75
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** The MM
2
conductor size referenced here is for both Class 2 and Class 5 conductor.
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connecotrs. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
TWO HOLE HYLUG™
FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(CONTINUED)
Conductor
Catalog Number
YAZV252TC14FX
YAZV252TC14FX45
YAZV252TC14FX90
YAZV252TC14E2FX
YAZV252TC14E2FX45
YAZV252TC14E2FX90
YAZV252TC38FX
YAZV252TC38FX45
YAZV252TC38FX90
YAZV252NTCFX
YAZV252NTCFX45
YAZV252NTCFX90
YAZV262TC14FX
YAZV262TC14FX45
YAZV262TC14FX90
YAZV262TC14E2FX
YAZV262TC14E2FX45
YAZV262TC14E2FX90
YAZV262TC38FX
YAZV262TC38FX45
YAZV262TC38FX90
YAZV262NTCFX
YAZV262NTCFX45
YAZV262NTCFX90
YAZV272TC14E2FX
YAZV272TC14E2FX-45
YAZV272TC14E2FX-90
YAZV272TC38FX
YAZV272TC38FX45
YAZV272TC38FX90
YAZV282TC14E2FX
YAZV282TC14E2FX45
YAZV282TC14E2FX90
YAZV282NT38FX
YAZV282NT38FX-45
YAZV282NT38FX-90
YAZV282TC38FX
YAZV282TC38FX45
YAZV282TC38FX90
YAZV282NTCFX
YAZV282NTCFX45
YAZV282NTCFX90
YAZV292NT516FX
YAZV292NT516FX-45
YAZV292NT516FX-90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
***
MM
2
Stud Stud
Hole Hole Tongue
Size Spacing Width
1/4
275/24
1/0 WELD
1/0 AWG
50
3/8
1
.83
5/8
.83
Figure
Dimensions
(B) (T)
(L)
3.20
1.50 .12 2.92
1.66
3.32
1.50 .12 3.04
1.79
3.76
1.50 .12 3.48
2.23
4.95
1.50 .12 4.67
3.41
3.20
1.50 .13 2.92
1.66
3.32
1.50 .13 3.05
1.79
3.76
1.50 .13 3.48
2.23
4.95
1.50 .13 4.67
3.41
3.36
1.50 .14 3.08
1.82
3.80
1.50 .14 3.52
2.25
3.52
1.62 .15 3.23
1.86
3.96
1.62 .15 3.67
2.30
3.96
1.62 .15 3.67
2.30
4.93
1.62 .15 4.64
3.27
4.62
2.00 .16 4.35
2.96
Dieless
(# of crimps)
B
B
90°
T
B
T
L
T
45°
L
L
Fig. 1
Fig. 2
Fig. 3
Mechanical
MD6, OUR840
MD7-34R
v
Installation Tooling
Hydraulic
Wire
BCT500HS
Y35,Y39,Y750 Color Die Strip
Y500CTHS Y46, BAT35, BAT750 Code Index Length
C-79
1/4
3/4
.83
W25VT (4) W25VT (4)
W25RT (4) W25RT (4)
X25RT (4) X25RT (4)
U25RT (2)
Pink
12 1-9/16
1/2
1-3/4
.83
1/4
325/24
2/0 WELD
2/0 AWG
70
3/8
5/8
.93
1/4
3/4
.93
1
.93
W26VT (4) W26VT (4)
W26RT (4) W26RT (4)
X26RT (4) X26RT (4)
MY29-11 (2)
Y644M (1)
U26RT (2)
Black
13 1-9/16
1/2
1-3/4
.93
450/24
3/0 WELD
3/0 AWG
1/4
95
3/8
3/4
1.03
1
1.03
W27VT (4) W27VT (4)
W27RT (4) W27RT (4)
X27RT (4) X27RT (4)
U27RT (2)
Orange 14 1-9/16
1/4
550/24
4/0 WELD
4/0 AWG
**
120
3/4
1.14
3/8
1
.94
3/8
1
1.14
W28VT (4) W28VT (4)
W28RT (4) W28RT (4)
X28RT (6) X28RT (6)
U28RT (2)
Purple 15 1-11/16
1/2
550/24
4/0 WELD
1-3/4
1.14
-
5/16
1-3/4
1.20
Y644M (1)
W29VT (4)
X29RT (8)
W29RT (4)
W29VT (4)
X29RT (8)
U29RT (2)
Yellow
16 1-11/16
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
** The MM
2
conductor size referenced here is for both Class 2 and Class 5 conductor.
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connectors. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.
BURNDY
Compression
TWO HOLE HYLUG™
FLEX CONDUCTOR
LONG BARREL WITH
INSPECTION WINDOW
(CONTINUED)
Conductor
C-80
Catalog Number
YAZ302TC38FX
YAZ302TC38FX-45
YAZ302TC38FX-90
YAZ312TC38FX
YAZ312TC38FX45
YAZ312TC38FX90
YAZ312TC14E2FX
YAZ312TC14E2FX-45
YAZ312TC14E2FX-90
YAZ322TC38FX
YAZ322TC38FX45
YAZ322TC38FX90
YAZ342TC14E2FX
YAZ342TC14E2FX-45
YAZ342TC14E2FX-90
YAZ342NT38FX
YAZ342NT38FX-45
YAZ342NT38FX-90
YAZ342TC38FX
YAZ342TC38FX45
YAZ342TC38FX90
YAZ342NTCFX
YAZ342NTCFX45
YAZ342NTCFX90
YAZ362TC38FX
YAZ362TC38FX45
YAZ362TC38FX90
YAZ382NT38FX
YAZ382NT38FX-45
YAZ382NT38FX-90
YAZ382TC38FX
YAZ382TC38FX45
YAZ382TC38FX90
YAZ382NNTFX
YAZ382NNTFX-45
YAZ382NNTFX-90
YAZ382NTCFX
YAZ382NTCFX45
YAZ382NTCFX90
Fig
#
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
AWG
250 FLEX
CLASS G 259 STR.
CLASS H 427 STR.
***
MM
2
Stud Stud
Hole Hole Tongue
Size Spacing Width
3/8
1
1.20
Figure
Dimensions
(B) (T)
(L)
4.42
2.00 .16 4.05
2.37
4.45
2.00 .18 4.10
2.41
4.02
2.00 .18 3.66
1.97
4.62
2.12 .19 4.25
2.46
4.42
2.25 .23 4.06
2.10
4.85
2.25 .23 4.50
2.54
4.85
2.25 .23 4.50
2.54
6.04
2.25 .23 5.69
3.73
5.55
2.69 .27 5.14
2.81
5.72
2.81 .27 5.26
2.84
5.72
2.81 .27 5.26
2.84
6.72
2.81 .27 6.26
3.84
6.72
2.81 .27 6.26
3.84
Dieless
(# of crimps)
B
B
90°
T
B
T
L
T
45°
L
L
Fig. 1
Fig. 2
Fig. 3
v
Installation Tooling
Mechanical
Hydraulic
Wire
MD6, OUR840 BCT500HS
Y35,Y39,Y750 Color Die Strip
MD7-34R
Y500CTHS Y46, BAT35, BAT750 Code Index Length
W29RT (4)
W29VT (4) W29VT (4)
U29RT (2)
Yellow 16 2-1/16
X29RT (8) X29RT (8)
250 FLEX
637/24 150
CLASS I, K, M
3/8
1
1.28
W30VT (4)
W30VT (4)
W30RT (4)
U30RT (4)
White
17 2-1/16
1/4
3/4
1.29
775/24
185
313.1 kcmil
3/8
1
1.55
W31VT (4)
W31VT (4)
W31RT (4)
U31RT (4)
Red
18 2-3/16
1/4
373.3 kcmil
925/24
(350 MCM NOM)
240
3/8
3/4
1.55
3/8
1
.96
W32VT (4)
Y644M (1)
W32VT (4)
W32RT (4)
U32RT (4)
Blue
19 2-5/16
1
1.55
1/2
1100/24
444.4 kcmil
1-3/4
1.55
-
3/8
1
1.72
-
-
U34RT (4)
Brown
20
2-3/4
3/8
535.3 kcmil
1325/24
(500 MCM NOM)
300
1/2
1
1.63
3/8
1
1.81
-
-
U38XRT (4)
Pink
L99 2-7/8
1-3/4
1.63
1/2
1-3/4
1.81
* Use P-UADP-1 adaptor with "U" -dies in Y46 HYPRESS™.
*** The MM
2
conductor sizes listed are the recommendations for Class 5 conductor.
v
See tooling section of this catalog for complete tool and die listings. Use ONLY color-coded die recommendations for “-FX”
connecotrs. For nest/indentor system contact factory.
x
For applications greater than 2000 Volts consult cable manufacturer for voltage stress relief instructions.