ZWS Series
Single Output, 3.3W to 50W Power Supplies
Features
u
Universal Input (85 - 265VAC)
u
Input transient protected
u
2 year warranty
u
High quality design
u
Peak Power capability
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range
DC Input Voltage range
Inrush Current (100/200VAC) (1)
Temperature Coefficient
Overcurrent Protection (2)
Overvoltage Protection
Hold Up Time (Typ) @ 100VAC
Remote Sense
Operating Temperature
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated
Recommended EMI Filter
Weight (Typ)
Size (WxHxD)
Warranty
-
-
A
-
-
V
ms
-
°C
°C
°C
-
-
-
-
-
-
-
EM
-
g
mm
yrs
ZWS15
ZWS50
ZWS30
85-265VAC (47-440Hz)
110 - 330VDC
15 / 30
<0.02%/ºC
~125%
~140% diode clamp
~115 - 130%, manual reset
17
None
(open frame) -10ºC~+60ºC, derate linearly to 70% load from 50ºC~60ºC
(with cover) Additional derating applies, please consult Installation Manual
-30 to +85ºC
10 - 95% RH
Convection
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (100mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, CE Mark
EN55022-B, FCC Class B, VCCI-B
RSEL-20R5W
RSEL-2001W
RSEL-2002W
RSEL-2002W
120/120
140/270
370
See Outline Drawings
2 years
ZWS5
ZWS10
Notes:
(1) 25°C ambient (cold start)
(2) Avoid prolonged operartion in overload
1-800-526-2324 • www.us.tdk-lambda.com/lp/
113
Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZWS Series
2 Output Module Codes
Model
ZWS5-3
ZWS10-3
ZWS15-3
ZWS30-3
ZWS50-3
ZWS5-5
ZWS10-5
ZWS15-5
ZWS30-5
ZWS50-5
ZWS5-12
ZWS10-12
ZWS15-12
ZWS30-12
ZWS50-12
ZWS5-15
ZWS10-15
ZWS15-15
ZWS30-15
ZWS50-15
ZWS5-24
ZWS10-24
ZWS15-24
ZWS30-24
ZWS50-24
ZWS30-36
ZWS50-36
ZWS30-48
ZWS50-48
Adjust
Voltage Range
3.3V
3.3V
3.3V
3.3V
3.3V
5V
5V
5V
5V
5V
12V
12V
12V
12V
12V
15V
15V
15V
15V
15V
24V
24V
24V
24V
24V
36V
36V
48V
48V
2.97-3.63
2.97-3.63
2.97-3.63
2.97-3.63
2.97-3.63
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
13.5-16.5
13.5-16.5
13.5-16.5
13.5-16.5
13.5-16.5
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
32.4-39.6
32.4-39.6
43.2-52.8
43.2-52.8
Max Peak Load
Curr. Curr. Reg
A
A
mV
1
2
3
6
10
1
2
3
6
10
0.42
0.85
1.25
2.5
4.3
0.34
0.7
1
2
3.5
0.22
0.45
0.65
1.3
2.1
0.9
1.4
0.7
1.1
1.2
2.4
3.6
7.2
12
1.2
2.4
3.6
7.2
12
0.51
1.02
1.5
3
5.16
0.41
0.84
1.2
2.4
4.2
0.27
0.54
0.78
1.56
2.52
1.08
1.68
0.84
1.32
40
40
40
40
40
40
40
40
40
40
96
96
96
96
96
120
120
120
120
120
150
150
150
150
150
240
240
300
300
Line Ripple
Reg Noise Eff.
mV mV
%
20
20
20
20
20
20
20
20
20
20
48
48
48
48
48
60
60
60
60
60
96
96
96
96
96
144
144
192
192
120
120
120
120
120
120
120
120
120
120
150
150
150
150
150
150
150
150
150
150
200
200
200
200
200
300
300
400
400
62
62
63
70
73
67
70
71
75
77
68
70
71
77
80
68
71
71
77
81
70
71
71
78
82
78
82
78
82
ZWS Outline Drawing
A
C
INPUT
D
J
F
CN2
COMPONENT SIDE
CN1
OUTPUT
K
B
G
G
ZWS5-150 OUTLINE DRAWING
.118 MAX
(3.0)
E
H
DIMENSIONS:
MODEL
A
3.86
(98.0)
4.14
B
1.77
(44.9)
1.97
(50.0)
1.97
(50.0)
2.17
(55.1)
2.17
(55.1)
C
3.580
(90.9)
3.860
(98.0)
4.650
(118.1)
4.850
(123.1)
7.290
(185.1)
D
1.500
(38.1)
1.690
(42.9)
1.690
(42.9)
1.770
(45.0)
1.770
(45.0)
E
F
-
G
.14
H
.83
(21.0)
.83
(21.0)
.83
(21.0)
1.02
(25.9)
1.02
(25.9)
J
1.05
(26.6)
.99
(25.1)
1.04
(25.0)
.20
(31.0)
1.32
(33.5)
K
.54
(13.7)
.67
(18.4)
.57
(14.4)
1.16
(40.2)
.72
(18.2)
L
-
ZWS5
-
(3.5)
.14
-
ZWS10
(105.1)
4.93
-
-
(3.5)
.14
ZWS15
(125.2)
5.24
ZWS30
(133.0)
ZWS50
7.68
(195.0)
-
-
-
(3.5)
.20
-
-
-
(5.0)
.20
-
-
-
(5.0)
Other Industrial Products
ZWS-AF
ZWD/ZWQ
SC
HWS
50W to 150W Active PFC
100W to 440W Single & multiple output
30W to 120W Single, dual, & triple output
15W to 1800W Single output enclosed
Note for Peak Current: For 10s maximum, 35% duty cycle, average
power not to exceed maximum ratings.
Options
Suffix
-
/A
/J
/JA
Note:
Description
Molex Terminals
Cover option
JST Connectors*
JST Connectors & Cover
* Recommended for new designs
For Additional Information, please visit
us.tdk-lambda.com/lp/products/zws-series.htm
1-800-526-2324 • www.us.tdk-lambda.com/lp/
114