Notes: 1) In Mark mode, L-ON/D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and
press the OFF key at the base (non-mark area). When doing so, the operator does not have to consider L-ON/D-ON.
2) Sensing accuracy can be set to either FINE (standard) or COARSE.
3) The percent display is only enabled in mark mode.
4) ECO mode is a function that reduces power consumption by turning off the digital display in the event that no button operations are made for
a predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again.
5) The turn mode is a function that reverses the digital display making it easily to be viewed in the event that the sensor installation renders the display up-side-down.
* Default setting: D-code = “
”.
Super simple teaching
Press the ON button at the targeted mark.
Here is an example of the most basic setting method
“2-level teaching”.
Mode selection
Press MODE key and select TEACH mode.
External teaching possible
Teaching is possible through external input using an
operation panel or touch panel even on hard-to-reach
color mark sensors located inside an equipment. Also,
models can be interchanged easily.
Mark mode
2-level teaching and full-auto teaching possible
Teaching
1
Align the spot on the mark and press the ON key.
2
Align the spot onto the base (non-mark area) and press the OFF key.
* The
1 2
order can be reversed.
Display showing
complete settings
Color mode
1-level teaching possible
Sensing
Teaching complete. The optimal LED is
automatically selected and the sensor
automatically returns to RUN mode.
Other teaching methods
• Full-auto teaching: In Mark mode, teaching is effective
without stopping the sensing object.
• 1-level teaching: In Color mode, the color detected is aligned
by the spot and teaching is effective.
Compact design for significant space savings
High precision sensing and multiple functions are all
packed in a compact W57 × D24 × H38 mm
W2.244
× D0.945 × H1.496 in
body.
Cable and plug-in connector
types are available
depending on the
equipment used.
These sensors can
be easily introduced
38 mm
1.496 in
to existing facilities.
24 mm
0.945 in
57 mm
2.244 in
Key lock function
The key lock function enables input operation control
that prevents mistaken changes in the sensor settings.
Other detailed settings include “RUN adjust”, allowing
threshold value adjustment only, and “RUN teaching”,
allowing teaching operation only.
If the sensor is set to “RUN adjust” or “RUN teaching”,
adjustment and teaching are possible having the sensor