Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1036A Triad - 300V Power-Limited Tray Cable
For more Information
please call
1-800-Belden1
Description:
18 AWG triads stranded (7x26) bare copper conductors, twisted triads, PVC insulation, overall Beldfoil
shield (100% coverage), PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Triads AWG Stranding Conductor Material
1
18
7x26
BC - Bare Copper
Insulation
Insulation Material:
Insulation Material
PVC - Polyvinyl Chloride
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material
Beldfoil®
Coverage (%)
Tape Aluminum Foil-Polyester Tape 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20
7x28
TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.9398
Outer Jacket Ripcord:
Yes
Overall Cable
Overall Cabling Color Code Chart:
Number Color
1
Black & White & Red
Overall Nominal Diameter:
5.994 mm
Mechanical Characteristics (Overall)
Operating Temperature Range:
Bulk Cable Weight:
Max. Recommended Pulling Tension:
Min. Bend Radius (Install)/Minor Axis:
-30°C To +105°C
61.909 Kg/Km
400.338 N
60.960 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification:
CEC/C(UL) Specification:
AWM Specification:
PLTC, ITC, CMG
CMG
UL Style 2464 (300 V 80°C)
Page 1 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1036A Triad - 300V Power-Limited Tray Cable
EU CE Mark:
EU Directive 2000/53/EC (ELV):
EU Directive 2002/95/EC (RoHS):
EU RoHS Compliance Date (mm/dd/yyyy):
EU Directive 2002/96/EC (WEEE):
EU Directive 2003/11/EC (BFR):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Yes
04/01/2005
Yes
Yes
Yes
Yes
Flame Test
CSA Flame Test:
IEEE Flame Test:
ICEA Flame Test:
FT4
1202
T-29-520
Suitability
Suitability - Burial:
Sunlight Resistance:
Yes
Yes
Plenum/Non-Plenum
Plenum (Y/N):
No
Surface Printing (Overall)
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.55777
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
164.05
Nom. Conductor DC Resistance:
Description DCR @ 20°C (Ohm/km)
18 AWG
19.2267
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
16.6347
Max. Operating Voltage - UL:
Voltage
300 V RMS
Related Documents:
No related documents are available for this product
Put Ups and Colors:
Item #
1036A 0061000
1036A 00610000
1036A 0065000
1036A 0101000
1036A 01010000
1036A 0105000
Putup
305 MT
3,048 MT
1,524 MT
305 MT
3,048 MT
1,524 MT
Ship Weight
18.144 KG
190.510 KG
90.719 KG
18.144 KG
195.046 KG
90.719 KG
Color
BLUE, LIGHT
BLUE, LIGHT
BLUE, LIGHT
BLACK
BLACK
BLACK
Notes
C
C
CZ
C
CZ
Item Desc
3 #18 PVC FS PVC
3 #18 PVC FS PVC
3 #18 PVC FS PVC
3 #18 PVC FS PVC
3 #18 PVC FS PVC
3 #18 PVC FS PVC
Notes:
C = CRATE REEL PUT-UP.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Page 2 of 3
02-24-2012
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
1036A Triad - 300V Power-Limited Tray Cable
Revision Number: 1
© 2012 Belden, Inc
All Rights Reserved.
Revision Date: 05-14-2007
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
02-24-2012