Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
High Performance High Current 3-phase Delta RFI Filters
ADT Series
UL Recognized
ADT Series
• Designed for very high insertion loss for Delta
three phase, three wire applications
• Available with common or differential mode coils
Specifications
Maximum leakage current at 277 VAC 60 Hz,
each Line to Ground:
ADT6:
63ADT6S:
100, 160, 200ADT6S
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
Phase to Phase:
Phase to Ground:
1.3 A
2.6 A
4.6 A
2
Three Phase Filters
2210 VDC
2158 VDC
480 VAC
277 VAC
50/60 Hz
63 to 200A
Ordering Information
100 ADT 6 S
Suffix
S – Differential mode coils
Omit if none
Input / Output Style
6 – Threaded bolt
ADT Series
Current Rating
63, 100, 160 or 200A
Operating Frequency:
Rated Current:
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
(85-Ta)/45
Electrical Schematics
63ADT6
LINE
A
LOAD
A
Available Part Numbers
63ADT6
100ADT6
160ADT6
200ADT6
63ADT6S
100ADT6S
160ADT6S
200ADT6S
B
B
C
C
101
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
(continued)
High Performance High Current 3-phase Delta RFI Filters
ADT Series
Electrical Schematics
(continued)
100, 160 & 200 ADT6
LINE
A
B
C
LOAD
A
G
G
Case Style
A
2.00
F
1.00
B
C
1.18 x 0.56 Slot
(2x)
E
2.0 Max. (6x)
0.69 Typ.
0.75 x 0.44 Slot
(2x)
C
See Note
3/8-16 Thread
(7x)
Mounting
Bracket
ADT6S
LINE
A
LOAD
A
D
(2x)
K
(2x)
0.75
(2x)
H
0.75
0.75
J
C
L
C
L
B
B
B
C
C
C
L
C
L
Line
Load
Case Dimensions
Part No.
63ADT6
63ADT6S
100ADT6
100ADT6S
160/200ADT6
160/200ADT6S
A
B
C
D
E
F
G
H
J
K
102
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
(continued)
High Performance High Current 3-phase Delta RFI Filters
ADT Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
63ADT6
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
100ADT6
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
160ADT6
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
200ADT6
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
2
Three Phase Filters
63ADT6S
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
100ADT6S
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
160ADT6S
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
200ADT6S
db
100
90
80
70
60
50
40
30
20
10
0
0.01
0.1
1
10
100
300
Frequency in MHz
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
103
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com