首页 > 器件类别 > 连接器 > 接线终端

BFV14-8

COPPER ALLOY, TIN FINISH, FORK TERMINAL

器件类别:连接器    接线终端   

厂商名称:3M

厂商官网:http://3M.com/esd

下载文档
器件参数
参数名称
属性值
厂商名称
3M
Reach Compliance Code
unknown
ECCN代码
EAR99
制造商序列号
BFV
端子和端子排类型
FORK TERMINAL
线规
14 AWG
文档预览
Highland Terminals
C
W
BFV10-6 thru BFV18-10
Block Fork, Vinyl Insulated, Butted Seam
E
L
Data Sheet
Product
Number
Wire
Range
(AWG)
Stud
Size
W
C
L
E
Thickness
Barrel
Length
Barrel
I.D.
Maximum
Insulation
Diameter
BFV10-6
BFV10-8
BFV10-10
BFV14-6
BFV14-8
BFV14-10
BFV18-6
BFV18-8
BFV18-10
12-10
12-10
12-10
16-14
16-14
16-14
22-18
22-18
22-18
6
8
10
6
8
10
6
8
10
0.32
0.32
0.32
0.25
0.30
0.30
0.25
0.30
0.30
0.29
0.29
0.29
0.25
0.25
0.25
0.25
0.25
0.25
1.03
1.03
1.03
0.85
0.85
0.85
0.85
0.85
0.85
0.84
0.84
0.84
0.70
0.70
0.70
0.70
0.70
0.70
0.040
0.040
0.040
0.030
0.030
0.030
0.030
0.030
0.030
0.25
0.25
0.25
0.25
0.25
0.25
0..25
0.25
0.25
0.135
0.135
0.135
0.090
0.090
0.090
0.070
0.070
0.070
0.250
0.250
0.250
0.170
0.170
0.170
0.145
0.145
0.145
Installation Information
WARNING
UNDERWRITERS
LABORATORIES
STANDARD NO.
UL 486A
3M FILE NO. E23438
CANADIAN STANDARDS
ASSOCIATION
STANDARD NO. C22.2
NO. 0. 65
3M FILE NO. LR22190
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Specifications
Wire Size:
Barrel Seam:
Max. Voltage Rating:
Max. Temperature Rating:
Max. Current:
Insulator Material:
Terminal Material:
Plating:
See Table Above
Butted
600 V Building Wire
1000 V Signs, Fixtures
and Luminaires
221˚F (105˚C)
Same as Wire
Vinyl
ETP Copper
Tin
Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or
TR-490 (ratchet style) hand tools.
Barrel Crimp (Electrical)
Engineering Specification
Crimp-type terminals shall, electrically and
mechnically, connect to a pre-stripped end of a stranded
copper wire: and have a flat tongue portion with a
central opening for mounting around a screw or stud.
The terminal line shall offer tongue variations in hole
(stud) size (6, 8 10, etc.) and configuration (ring, fork,
block fork, flanged block fork, locking fork, etc.): and
barrel variations in wire (AWG) size (22-18, 16-14, 12-
10, etc.) and construction (non-insulated brazed seam,
vinyl insulated butted seam, nylon insulated with
insulation grip, etc.). The terminal line shall have
regulatory agency coverage (UL Listing, CSA
Certification). The terminal tongue shall be marked
with the wire range and manufacturer’s symbol ( ).
The vinyl-insulated, butted seam block fork terminal
shall be tin-plated, annealed copper, with the tongue
having a specified stud slot (size 6 thru 10) and a butted
seam barrel covered by a molded vinyl funnel entry
sleeve, color coded and sized, for a specified (AWG)
wire range (22-18, 16-14, 12-10).
Insulated terminals shall be UL Listed and CSA
Certified for 600 Volts maximum building wire: 1000
Volts maximum in signs, fixtures and luminaries and
have a maximum operating temperature of 221°F
(105°C).
3M and Highland are trademarks of 3M
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture as of the date of purchase.
3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
If this product is defective within the warranty period stated above, your exclusive remedy shall be,
at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product.
Except where prohibited by law, 3M will
not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential
regardless of the legal theory asserted.
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/elpd
Litho in USA.
© 3M 2002 78-8126-0631-3-A
查看更多>
参数对比
与BFV14-8相近的元器件有:BFV14-6、BFV10-8、BFV10-6、BFV10-10。描述及对比如下:
型号 BFV14-8 BFV14-6 BFV10-8 BFV10-6 BFV10-10
描述 COPPER ALLOY, TIN FINISH, FORK TERMINAL COPPER ALLOY, TIN FINISH, FORK TERMINAL COPPER ALLOY, TIN FINISH, FORK TERMINAL COPPER ALLOY, TIN FINISH, FORK TERMINAL COPPER ALLOY, TIN FINISH, FORK TERMINAL
厂商名称 3M 3M 3M 3M 3M
Reach Compliance Code unknown unknown unknown unknown unknown
ECCN代码 EAR99 EAR99 EAR99 EAR99 EAR99
制造商序列号 BFV BFV BFV BFV BFV
端子和端子排类型 FORK TERMINAL FORK TERMINAL FORK TERMINAL FORK TERMINAL FORK TERMINAL
线规 14 AWG 14 AWG 10 AWG 10 AWG 10 AWG
热门器件
热门资源推荐
器件捷径:
E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF EG EH EI EJ EK EL EM EN EO EP EQ ER ES ET EU EV EW EX EY EZ F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF FG FH FI FJ FK FL FM FN FO FP FQ FR FS FT FU FV FW FX FY FZ G0 G1 G2 G3 G4 G5 G6 G7 G8 G9 GA GB GC GD GE GF GG GH GI GJ GK GL GM GN GO GP GQ GR GS GT GU GV GW GX GZ H0 H1 H2 H3 H4 H5 H6 H7 H8 HA HB HC HD HE HF HG HH HI HJ HK HL HM HN HO HP HQ HR HS HT HU HV HW HX HY HZ I1 I2 I3 I4 I5 I6 I7 IA IB IC ID IE IF IG IH II IK IL IM IN IO IP IQ IR IS IT IU IV IW IX J0 J1 J2 J6 J7 JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ JR JS JT JV JW JX JZ K0 K1 K2 K3 K4 K5 K6 K7 K8 K9 KA KB KC KD KE KF KG KH KI KJ KK KL KM KN KO KP KQ KR KS KT KU KV KW KX KY KZ
需要登录后才可以下载。
登录取消