• A Unit supports four input channels, each of which can be set to a
platinum resistance thermometer, thermocouple, and DC signal
(current, voltage). All inputs are isolated.
CJ1W-PH41U
CJ1W-AD04U
Features
•
Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately
for each input.)
•
Isolation between input channels prevents unwanted current paths between input channels.
•
Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.
•
Process value alarm with two alarms for each input
•
Alarm ON-delay timer and hysteresis for process value
•
Zero/Span adjustment capability during operation
•
Input error detection
•
Maximum or minimum process value can be specified for when an input error is detected.
•
A Unit with fully universal inputs, high-speed and high-resolution (256,000 resolution, 60 ms/ch is available.)
1
CJ1W-PTS/PDC/PH41U/AD04U
Ordering Information
International Standards
• The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2
Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
• Contact your OMRON representative for further details and applicable conditions for these standards.
Process I/O Units
Isolated-type Thermocouple Input Units
Unit
classification
Product
name
Input
points
Signal
range
selection
Signal range
Conversion
speed
(resolution)
Conversion
speed:
10 ms/
2 inputs,
Resolution:
1/64,000
Conversion
speed:
250 ms/
4 inputs
Accuracy
(at ambient
temperature of
25°C)
Standard
accuracy:
±0.05%
of F.S.
*1
Accuracy:
(±0.3% of PV or
±1°C,
whichever
is larger)
±1
digit
max.
*3
External
connection
Current
No. of
consumption
unit
(A)
numbers
allocated 5 V
24 V
Model
Standards
CJ1
Special I/O
Units
Process
Set
Input Units
2
separately
(Isolated-type
inputs for each
Thermocouple
input
Input Units)
Thermocouple:
B, E, J, K, L, N,
R, S, T, U,
WRe5-26, PLII
DC voltage:
±100
mV
Thermocouple:
R, S, K, J, T, L,
B
0.18
Removable
terminal
block
0.06
*2
CJ1W-PTS15
1
UC1, CE
Common
4
inputs inputs
0.25
−
CJ1W-PTS51
Note:
This unit cannot be used, with the Machine Automation Controller NJ-series.
*1. The accuracy depends on the sensors used and the measurement temperatures. For details, refer to the user's manual.
*2. This is for an external power supply, and not for internal current consumption.
*3. L and
−100°C
or less for K and T are
±2°C±1
digit max., and 200°C or less for R and S is
±3°C±1
digit max. No accuracy is specified for 400°C
or less for B.
Isolated-type Resistance Thermometer Input Units
Unit
classification
Product
name
Signal
Input
range
points
selection
Signal range
Conversion
speed
(resolution)
Conversion
speed:
10 ms/
2 inputs,
Resolution:
1/64,000
Accuracy
(at ambient
temperature of
25°C)
Accuracy:
±0.05%
of F.S.
or
±0.1°C,
whichever is
larger.
Accuracy:
±0.3%
of PV or
±0.8°C,
whichever is
larger,
±1
digit
max.
External
connection
Current
No. of
consumption
unit
(A)
numbers
allocated 5 V
24 V
Model
Standards
CJ1
Special I/O
Units
Process
Set
Analog Input
2
separately
Units
(Isolated-type
inputs for each
input
Resistance
Thermometer
Input Units)
Resistance
thermometer:
Pt100, JPt100,
Pt50, Ni508.4
0.18
Removable
terminal
block
0.07
*
CJ1W-PTS16
1
UC1, CE
Common
4
inputs inputs
Resistance
thermometer:
Pt100, JPt100
Conversion
speed:
250 ms/
4 inputs
0.25
−
CJ1W-PTS52
Note:
This unit cannot be used, with the Machine Automation Controller NJ-series.
* This is for an external power supply, and not for internal current consumption.
Isolated-type DC Input Units
Unit
classification
Product
name
Isolated-
type DC
Input Units
CJ1
Special I/O
Units
Input
points
Signal range selection
Conversion
speed
(resolution)
Accuracy
(at ambient
temperature of
25°C)
External
connection
Current
No. of
consumption
unit
(A)
numbers
allocated 5 V
24 V
Model
Standards
DC voltage:
0 to 1.25 V,
−1.25
to 1.25 V,
0 to 5 V, 1 to 5 V,
−5
to 5 V,
2
0 to 10 V,
−10
to 10 V,
inputs
±10
V selectable range
DC current:
0 to 20 mA, 4 to 20 mA
Conversion
speed:
10 ms/
2 inputs
Resolution:
1/64,000
Accuracy:
±0.05%
of F.S.
Removable
terminal
block
1
0.18
0.09
*
CJ1W-PDC15
UC1, CE
* This is for an external power supply, and not for internal current consumption.
2
CJ1W-PTS/PDC/PH41U/AD04U
Isolated-type Units with Universal Inputs
Unit
classification
Product
name
Input
points
Signal
range
selection
Signal range
Conversion
speed
(resolution)
Accuracy
(at ambient
temperature of
25°C)
Accuracy:
Platinum
resistance
thermometer
input:
±0.3%
of
PV or
±0.8°C,
whichever is
larger)
±1
digit
max.
Thermocouple
input: (±0.3% of
PV or
±1.5°C,
whichever is
larger)
±1
digit
max. *1
Voltage or
current input:
±0.3%
of F.S.
±1
digit max.
Removable
terminal
block
External
connection
Current
No. of
consumption
unit
(A)
numbers
allocated 5 V
24 V
Model
Standards
Fully universal
inputs:
Pt100, JPt100,
Set
Pt1000, K, J, T,
separately L, R, S, B,
4
4 to 20 mA,
inputs for each
0 to 20 mA,
input
1 to 5 V,
0 to 5 V,
0 to 10 V
Process
Input Units
(Isolated-
type Units
with
Universal
CJ1
Special I/O Inputs)
Units
Conversion
speed:
250 ms/
4 inputs
0.32
−
CJ1W-AD04U
UC1,
CE, L
Universal
inputs:
Pt100 (3-wire),
JPt100 (3-wire),
Pt1000 (3-wire),
Pt100 (4-wire),
K, J, T, E, L, U,
N, R, S, B,
WRe5-26, PL II,
4 to 20 mA,
0 to 20 mA,
Set
1 to 5 V,
separately
4
0 to 1.25 V,
inputs for each
0 to 5 V,
input
0 to 10 V,
±100
mV
selectable
range
−1.25
to 1.25 V,
−5
to 5 V,
−10
to 10 V,
±10
V
selectable
range,
potentiometer
1
Resolution
(conversion
speed):
1/256,000
(conversion
cycle:
60 ms/
4 inputs)
Standard
1/64,000
accuracy:
(conversion ±0.05% of F.S.
cycle:
10 ms/
4 inputs)
1/16,000
(conversion
cycle: 5 ms/
4 inputs)
0.30
−
CJ1W-PH41U
*2
UC1, CE
*1. L and
−100°C
or less for K and T are
±2°C±1
digit max., and 200°C or less for R and S is
±3°C±1
digit max. No accuracy is specified for 400°C
or less for B.
*2. Do not connect a Relay Contact Output Unit in the same CPU Rack or Expansion Rack as the CJ1W-PH41U Isolated-type Universal Input Unit.
3
CJ1W-PTS/PDC/PH41U/AD04U
System Overview
These Analog I/O Units belong to the CJ-series Special I/O Unit group.
•
They can be mounted to CJ-series CPU Racks or Expansion I/O Racks.
The number of Units that can be mounted to one Rack (either a CPU Rack or Expansion I/O Rack) depends upon the maximum current supplied
by the Power Supply Unit and the current consumption by the other Units.
There are no restrictions on Rack position.
10 I/O Units max.
CPU Rack
CPU Unit
Power
Supply Unit
Power
Supply Unit
I/O Control Unit
End Cover
CJ-series Expansion
Rack
Expansion
Racks
3 maximum
I/O Interface Unit
I/O Interface Unit
CJ-series Expansion
Rack
Note:
I/O addresses for Special I/O Units are allocated according to the unit number set on the switches on the front panel, and not according to
the slot position in which they are mounted.
Mountable Racks
NJ system
Model
CJ1W-PTS15
CJ1W-PTS51
CJ1W-PTS16
CJ1W-PTS52
CJ1W-PDC15
CJ1W-AD04U
CJ1W-PH41U
CPU Rack
Expansion Rack
CJ system (CJ1, CJ2)
CPU Rack
Expansion
Backplane
CP1H system
CP1H PLC
NSJ system
NSJ Controller
Expansion
Backplane
Power
Supply Unit
10 I/O Units max.
Not supported
10 Units
10 Units
10 Units
(per Expansion
Rack)
10 Units
(per Expansion
Backplane)
2 Units
Not supported
10 Units
(per Expansion
Backplane)
4
CJ1W-PTS/PDC/PH41U/AD04U
Common Specification
Item
Unit classification
Dimensions
Weight
Maximum number of Units
Ambient operating temperature
Ambient operating humidity
CJ-series Special I/O Unit
31
×
90
×
65 mm (W
×
H
×
D)
150 g max.
40 Units (10 Units
×
4 Racks)
Confirm that the total current consumption of all the Units (including the CPU Unit) mounted to a single
CPU Rack or Expansion Rack does not exceed the maximum power supplied by the Power Supply Unit.