EPL150 Series
150 Watts
• 100 W Convection/150 W Forced-cooled Ratings
• 2” by 4” Footprint
• Low 0.99” Profile
• Class I & Class II Operation
• 12 V Fan Output
• High Efficiency, up to 95%
• ITE & Medical (BF) Approvals
• High Power Density
• Less than 0.5 W No Load Input Power
• 3 Year Warranty
AC-DC Power Supplies
Dimensions:
The EPL150 series maximises efficiency across the load range and minimises no load power
consumption minimising heat dissipation, reducing running costs and enabling compliance with the
latest environmental goals and legislation. Fully approved as Class I & Class II for ITE, Industrial and
Medical applications the EPL150 provides up to 100 W when convection cooled and up to 150 W
when force cooled at just 10 CFM. A 12 V 0.5 A fan supply is included to support force cooled
applications. The small footprint, low profile, low noise and comprehensive safety agency approvals
allow this versatile product to be used in a wide range of ITE and industrial applications.
EPL150:
4.00 x 2.00 x 0.99” (101.6 x 50.8 x 25.1 mm)
Models & Ratings
Output
Power
150 W
150 W
150 W
150 W
150 W
150 W
150 W
Notes
1. Requires 10 CFM.
2. Minimum average efficiencies measured at 25%, 50%, 75% & 100% of 150 W load and 230 VAC input.
Output
Voltage
12.0 V
15.0 V
18.0 V
24.0 V
28.0 V
36.0 V
48.0 V
Output Current
Convection-cooled
Forced-cooled
(1)
8.33 A
6.67 A
5.56 A
4.17 A
3.50 A
2.78 A
2.08 A
12.50 A
10.00 A
8.33 A
6.25 A
5.40 A
4.17 A
3.10 A
Fan Output
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
12 V/0.5 A
Efficiency
(2)
93%
93%
93%
93%
93%
93%
93%
Model Number
EPL150PS12
EPL150PS15
EPL150PS18
EPL150PS24
EPL150PS28
EPL150PS36
EPL150PS48
Summary
Characteristic
Input Range
No Load Input Power
Efficiency
Operating Temperature
EMC
Safety Approvals
-20
CB/EN/UL/CSA for ITE and Medical
95
+70
Minimum
80
Typical
115/230
Maximum
264
0.5
Units
VAC
W
%
°C
230 VAC (see fig.1 & 2)
See derating curve (fig.3)
Notes & Conditions
Derate load from 100% at 90 VAC to 90% at 85 VAC and
85% at 80 VAC
Conducted: EN55011/32, Class B, Radiated: EN55011/32, Class A (Class B with external core, see EMC Emissions for details)
1
www.xppower.com
EPL150 Series
Input
Characteristic
Input Voltage - Operating
Input Frequency
Power Factor
Input Current - Full Load
Inrush Current
Earth Leakage Current
No load Input Power
Input Protection
Minimum
80
47
Typical
115/230
50/60
>0.9
2.2/1.1
120
80/140
230
0.5
F3.15 A/250 V Internal fuse fitted in line and neutral.
Maximum
264
63
AC-DC Power Supplies
Units
VAC
Hz
Notes & Conditions
Derate output from 100% at 90 VAC to 90% at 85 VAC and
85% at 80 VAC
230 VAC, 100% load EN61000-3-2 class A
A
A
µA
W
115/230 VAC
230 VAC cold start, 25
ºC
115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max)
Output - Main Output
Characteristic
Output Voltage - V1
Initial Set Accuracy
Output Voltage Adjustment-V1
Minimum Load
Start Up Delay
Hold Up Time
Drift
Line Regulation
Load Regulation
Transient Response
Over/Undershoot
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature Coefficient
Overtemperature Protection
0.02
%/˚C
°C
Measured internally, Auto Resetting
110
110
10
20/13
±0.02
±0.5
±0.5
4
7
1
140
170
0
2
Minimum
12
Typical
Maximum
48
±1
Units
VDC
%
%
A
s
ms
%
%
%
%
%
% pk-pk
%
% I nom
Trip & Restart
115/230 VAC full load.
Min at full load, 115 VAC. Typical at 100W/150W
After 20 min warm up
90-264 VAC
0-100% load.
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
Full load
20 MHz bandwidth and 10
µF electrolytic capacitator in
parallel with 0.1 µF ceramic capacitator.
Vnom, recycle input to reset
Notes & Conditions
See Models and Ratings table
50% load, 115/230 VAC
None
www.xppower.com
2
EPL150 Series
General
Characteristic
Efficiency
Isolation: Input to Output
Input to Ground
Output to Ground
Patient Leakage
Switching Frequency
Power Density
Mean Time Between Failure
Weight
300
0.43(195)
40
50
4000
1500
1500
50
130
95
Minimum
Typical
94
AC-DC Power Supplies
Maximum
Units
%
VAC
VAC
VAC
µA
kHz
kHz
W/in
3
Notes & Conditions
230 VAC (see fig. 1 & 2)
2 MOPP
1 MOPP
1 MOPP
At 264 VAC, 50 Hz
PFC
Main converter
Forced/convection-cooled
MIL-HDBK-217F, Notice 2 +25
°C GB
18.9/12.6
kHrs
lb(g)
Efficiency Vs Load
Figure 1
EPL150PS24
100 W
100%
95%
90%
Efficiency
85%
80%
75%
70%
65%
60%
10
20
30
40
50
60
70
80
90
100
115Vac
230Vac
Load (%)
Figure 2
EPL150PS24
150 W
100%
95%
90%
Efficiency
85%
80%
75%
70%
65%
60%
10
20
30
40
50
60
70
80
90
100
115Vac
230Vac
Load (%)
3
www.xppower.com
EPL150 Series
Environmental
Characteristic
Operating Temperature
Storage Temperature
Cooling
Humidity
Operating Altitude
Shock
Vibration
Minimum
-20
-40
10
5
95
Typical
AC-DC Power Supplies
Maximum
+70
+85
Units
°C
°C
CFM
%RH
m
Notes & Conditions
See derating curve, fig.3
Forced-cooled > 150W
Non-condensing
5000
±3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms (+/- 0.5msecs), half sine. Conforms to EN60068-2-27
Single axis 10-500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6
Temperature Derating Curve
Figure 3
Output Load (%)
100
50
0
-20
0
+50
+70
Ambient Temperature (ºC)
EMC: Emissions
Phenomenon
Conducted
Radiated
Harmonic Current
Voltage Functions
Standard
EN55011/22
EN55011/22
EN61000-3-2
EN61000-3-3
Test Level
Class B
Class A
Class A
Class B with King Core
K5B RC 13 x 23 x 7 on input cable and
K5B T 25 x 12 x 5 on output cable.
Criteria
Notes & Conditions
EMC: Immunity
Phenomenon
Medical Device EMC
Low Voltage PSU EMC
ESD
Radiated
EFT
Surges
Conducted
Magnetic Fields
Standard
IEC60601-1-2
EN61204-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN55024 (100 VAC)
Test Level
Ed.4.0 : 2014
High severity level
4
3
3
Installation class 3
3
4
Dip >95% (0 VAC), 8.3 ms
Dip 30% (70 VAC), 416 ms
Dip >95% (0 VAC), 4160 ms
Dip >95% (0 VAC), 10.0 ms
EN55024 (240 VAC)
Dip 30% (168 VAC), 500 ms
Dip
100% (0 VAC), 10.0 ms
Dip 100% (0 VAC), 20 ms
Dip >95% (0 VAC), 5000 ms
Criteria
as below
as below
A
A
A
A
A
A
A
A
B
A
A
B
A
B
B
B
A
B
A
B
A
A
±8kV contact, ±15kV air
Notes & Conditions
Dips and Interruptions
EN60601-1-2 (100 VAC)
Dip 60% (40 VAC), 100 ms
Dip 30% (70 VAC), 500 ms
Dip
100% (0 VAC), 10.0 ms
Dip 100% (0 VAC), 20 ms
Dip 100% (0 VAC), 5000 ms
Dip 60% (96 VAC), 100 ms
EN60601-1-2 (240 VAC)
Dip 30% ( 168 VAC), 500 ms
Dip 100% (0 VAC), 5000 ms
www.xppower.com
4
EPL150 Series
Safety Approvals
Safety Agency
CB Report
UL
TUV
CB Report
UL
EN
Safety Standard
IEC60950-1-1, IEC62368-1
UL60950-1, UL62368-1
EN62368-1
IEC60601-1
ES60601-1
EN60601-1
AC-DC Power Supplies
Notes & Conditions
Information Technology
Information Technology
Information Technology
Medical
Medical
Medical
Isolation
Primary to Secondary
Primary to Earth
Secondary to Earth
Safety Standard
2 x MOPP (Means of Patient Protection)
1 x MOPP (Means of Patient Protection)
1 x MOPP (Means of Patient Protection)
Notes & Conditions
Suitable for use as BF applied part application
Mechanical Details
0.06
(1.6)
0.83
(21.0)
4.0 (101.6)
3.75 (95.3)
0.10 (2.5)
L4
1.75
(44.5)
2.00
(50.8)
CN1
TR1
C2
C13
Mounting screw holes (in 4 positions)
CN1
Pin 1
Pin 2
Pin 3
AC-N
Mates with JST VHR-3N housing
and SVH-21T-P1.1 crimps
AC-L
CN2
C52
CN3
0.13 (ø3.2)
CN2
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
+Vo
+Vo
+Vo
Com
Com
Com
Pin 1
Pin 2
CN3
Fan -
Fan +
Mates with Molex 22-01-1022
housing and 2759 crimps
Mates with JST VHR-6N housing
and SVH-21T-P1.1 crimps
Mounting holes marked with
must be connected to safety earth in Class I application or connected together in Class II application.
Notes
1. All dimensions shown in inches (mm).
Tolerance: ±0.02 (0.5)
2. Weight: XXX lbs (XXX g) approx.
5
www.xppower.com