1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
PART NUMBER KEY
ETMA120500UD
-
XX
-
IC
-
CXX
Base Number
Reserved for Custom
Configurations
example of 12 Vdc, 5 A
DC Plug Type:
See output plug options on
page 3 for more details
Factory
Designation
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
ETMA 60W UD│
DESCRIPTION:
MEDICAL AC-DC POWER SUPPLY
date
06/20/2017
│
page
2 of 4
INPUT
parameter
voltage
frequency
inrush current
no load power consumption
at 240 Vac
conditions/description
min
90
47
typ
max
264
63
80
0.3
units
Vac
Hz
A
W
OUTPUT
parameter
line regulation
1
load regulation
2
voltage accuracy
hold-up time
switching frequency
temperature coefficient
Note:
1. measured from 100 ~ 240 Vac, full load
2. measured from 60% to full load and from 60 ~ 20% load (60% ±40% load)
conditions/description
12 Vdc output
15 Vdc output
all other outputs
at 115 Vac
min
typ
±1
±5
±3
±2
±2
8
100
±0.05
max
units
%
%
%
%
%
ms
kHz
%/°C
PROTECTIONS
parameter
over voltage protection
short circuit protection
conditions/description
TVS component to clamp
continuous, auto restart
min
typ
max
units
SAFETY & COMPLIANCE
parameter
isolation voltage
safety approvals
EMI/EMC
leakage current
MTBF
RoHS
as per MIL-HDBK-217F, 115 Vac, 25 °C
2011/65/EU
200,000
conditions/description
input to output
medical IEC 60601-1, EN 60601-1, UL 60601-1 4th edition
EN 55011, EN 60601-1-2, EN 61000-3-(2,3)
0.1
mA
hours
min
typ
max
5,656
units
Vdc
ENVIRONMENTAL
parameter
operating temperature
storage temperature
humidity
non-condensing
conditions/description
min
0
-20
typ
max
40
85
93
units
°C
°C
%
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
ETMA 60W UD│
DESCRIPTION:
MEDICAL AC-DC POWER SUPPLY
date
06/20/2017
│
page
3 of 4
MECHANICAL
parameter
dimensions
ø3.5 +0/-0.1
conditions/description
132 x 58 x 30.5 (5.2 x 2.28 x 1.2 inch)
IEC320 / C8
min
typ
max
units
mm
input plug
weight
14±0.5
345
g
MECHANICAL DRAWING
positive
*Tip
units: mm
58 0.5
P1R
C
A
B
30.5 0.5
Right Angle PXR
132 0.5
LED
A
Right Angle PXXR
B
C
DC OUTPUT PLUG OPTIONS / DC CORD
D
cord length
25±5
9±2
Standard PX
A
P5/P5R
P6/P6R
5.5
5.5
B
2.1
2.5
Right Angle PXR
C
9.5
9.5
Unit
mm
mm
MODEL NO.
ETMA120500UD
ETMA150400UD
ETMA180333UD
ETMA240250UD
CABLE GAUGE
16 AWG
16 AWG
16 AWG
16 AWG
16 AWG
16 AWG
CORD LENGTH
720 mm ±50
1,220 mm ±50
1,500 mm ±50
1,800 mm ±50
1,800 mm ±50
1,800 mm ±50
PXX
X X
Plug Type
Plug Angle:
“Blank” = Standard
R = Right Angle
Plug Polarity:
“Blank” = N/A
P = Center Positive
N = Center Negative
ETMA360166UD
ETMA480125UD
act CUI for additional output plug options.
cui.com
For more information, please visit the
product page
|
For information on related products, view
Dc Power Jacks
CUI Inc
│
SERIES:
ETMA 60W UD│
DESCRIPTION:
MEDICAL AC-DC POWER SUPPLY
date
06/20/2017
│
page
4 of 4
REVISION HISTORY
rev.
1.0
1.01
1.02
1.03
1.04
1.05
1.06
description
initial release
updated P7/P7R B dimension
V-Infinity branding removed
updated datasheet
corrected dc cord table
updated datasheet
updated to medical 60601-1 4th edition
date
12/16/2011
03/23/2012
08/21/2012
10/31/2012
07/02/2013
07/10/2015
06/20/2017
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
据外媒报道,英国的CORAM项目将允许自动驾驶汽车感知盲角(blind corners)内的障碍物,精准度高。这主要得益于其车载传感器,使互联及自动驾驶汽车的感知能力远胜于当前水平。 该项目负责一项可行性报告,由创新英国(Innovate UK)及该国的互联及自动驾驶汽车中心(Center for Connected And Autonomous Vehicles,CCAV)提供资金。该项目...[详细]