首页 > 器件类别 > 热门应用 > 测试测量

GE2502

Test Probes Oprobe x1, 35MHz 2500 Series,2.0m,ELD

器件类别:热门应用    测试测量   

厂商名称:Global Specialties

下载文档
GE2502 在线购买

供应商:

器件:GE2502

价格:-

最低购买:-

库存:点击查看

点击购买

器件参数
参数名称
属性值
产品种类
Product Category
Test Probes
制造商
Manufacturer
Global Specialties
RoHS
Details
工厂包装数量
Factory Pack Quantity
1
文档预览
Oscilloscope Probe
Sonde pour Oscilloscope
Tastkopf für Oszilloskop
GE2500 Series - 250 MHz
GE2501
GE2511
GE2512
GE2521
GE2502
GE2511RA
GE2512RA
GE2522
E LDI T ES T
© 2010 All rights reserved.
Elditest is a trademark of Sefram Instruments and Systems.
Elditest products are covered by US and foreign patents, issued and pending. In-
formation in this publication supersedes all earlier versions. Specifications sub-
ject to change without notice.
For product information, sales, service and technical support:
• In North America, call +1-714-221-9330 or visit www.caltestelectronics.com
• In Europe, call +33 (0)825 56 50 50 or visit www.sefram.fr
Model Number & Specifications
Model
Attn.
Input
Imped.
R (MΩ)
C (pF)
B/W
(MHz)
Rise Time
(ns)
Length
(m)
Compensation
Range
(pF)
GE2501
GE2502
GE2511
GE2511RA
GE2512
GE2512RA
GE2521
GE2522
1x
1x
10x
10x
10x
10x
1x/10x
1x/10x
1
1
10
10
10
10
1/10
1/10
45
65
12
12
14
14
45/12
65/14
55
35
250
250
190
190
25/250
17/190
6.4
10
1.4
1.4
1.8
1.8
14/1.4
21/1.8
1.2
2.0
1.2
1.2
2.0
2.0
1.2
2.0
-
-
10 - 30
10 - 30
10 - 30
10 - 30
10 - 30
10 - 30
(RA = Readout Actuator or Sense Pin)
2
ELDI TEST
Warranty
Elditest warrants its probes for normal use and operation within specification for a
period of one (1) year from the date of shipment (accessories and manual not in-
cluded).
In exercising its warranty, Elditest, at its option, will either repair or replace any as-
sembly returned within the warranty period. However, this will be done only if the
product is determined by Elditest’s examination to be defective because of work-
manship or materials, and the defect is not caused by misuse, neglect, accident,
abnormal conditions of operation, or damaged by attempted repair or modifica-
tions by non-authorized facility.
The customer will be responsible for the transportation and insurance charges for
the return of products.
This warranty replaces all other warranties, expressed or implied, including, but
not limited to, any implied warranty of merchantability, fitness, or adequacy for any
particular purpose or use. Elditest shall not be liable for any special, incidental or
consequential damages, whether in contract or otherwise.
RoHS
2002/95/EC
compliant
This electronic product is subject to disposal and recycling regulations
that vary by country and region. Many countries prohibit the disposal
of waste electronics equipment in standard waste receptacles.
Made in Taiwan
3
E LDI TE S T
General Safety Information
To avoid personal injury and to prevent fire or damage to the probe or any product
connected to it, review and comply with the following safety precautions.
Use of this probe or test instrument it is connected to in a manner not specified by
the manufacturers may impair protection mechanisms.
To avoid Personal Injury and Product Damage:
Connect to properly grounded instruments. Use only with test instruments having
their BNC input connected to earth ground. Do not connect the probe ground ter-
minal to any point which is at a potential other than earth ground.
Do not disconnect the probe from instrument during measurement. Connect the
probe to the measurement instrument before connecting the probe to the test cir-
cuit.
Do not apply to the input any potential that exceeds the maximum rating of the
probe.
Comply with the voltage derating curve. When measuring higher frequency sig-
nals, be sure to comply with the Voltage vs Frequency Derating Curve.
Do not remove probe casing. Removal of the probe’s casing may expose you to
electric shock.
Do not use if any part is damaged. All maintenance should be referred to a quali-
fied service personnel only.
Do not use in wet or explosive atmospheres.
For indoor use only.
Symbols and Terms
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in
injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
The following symbols may appear on the product:
D
ANGER
High Voltage
A
TTENTION
Refer to Manual
D
OUBLE
I
NSULATION
Protective
(E
ARTH
) T
ERMINAL
4
ELDI TEST
Basic Operation
The GE2500 Series are passive high impedance voltage oscilloscope probes de-
signed and calibrated for use with general purpose oscilloscopes having an input
impedance of 1 MΩ shunted by 13 pF, however selected models may be compen-
sated for use with instruments having an input capacitance between 10 to 30 pF.
Models with RA suffix are compatible with readout function oscilloscopes that au-
tomatically detect probe attenuation and adjust their readout scale accordingly.
WARNING. To avoid electric shock, keep fingers behind the probe’s finger guard
during use.
Probe Compensation
Proper compensation of the probe is required to assure amplitude accuracy of the
waveform being measured by matching the probe to the oscilloscope’s input ca-
pacitance. Compensation should be adjusted whenever the probe is connected to
or transferred between oscilloscopes.
Procedure:
Low Frequency (LF):
• Apply a 1 kHz square wave to the probe or connect to the oscilloscope’s
calibrator output.
• Adjust the trimmer located on the probe body (LF) for a flat topped square wave
per center illustration.
Incorrect
Correct
Incorrect
High frequency (HF):
(Should seldom require adjustment, however, if adjustment is required)
• Apply a 1 MHz square wave to the probe (<0.7 ns rise-time).
• Adjust trimmer located on the probe body (HF) toward cable end for a flat
topped square wave per center illustration.
5
Incorrect
Correct
Incorrect
查看更多>
参数对比
与GE2502相近的元器件有:GE2512、GE2522、GE2512RA、GE2511RA、GE2521SA、GE2521、GE2501、GE2511。描述及对比如下:
型号 GE2502 GE2512 GE2522 GE2512RA GE2511RA GE2521SA GE2521 GE2501 GE2511
描述 Test Probes Oprobe x1, 35MHz 2500 Series,2.0m,ELD Test Probes Oprobe x10, 190MHz 2500 Series,2.0m,ELD Test Probes Oprobe x1/x10,17/190 MHz-2500 Series,2.0m Test Probes Oprobe x10,190MHz RA 2500 Series,2.0m,ELD Test Probes Oprobe x10,250MHz RA 2500 Series,1.2mELD Test Probes Oprobe x1/x10,25/250 MHz w/InBNC - 2500 Test Probes Oprobe x1/x10, 25/250MHz 1.2m,ELD Test Probes Oprobe x1, 55MHz 2500 Series,1.2m,ELD Test Probes Oprobe x10, 250MHz 2500 Series,1.2m,ELD
产品种类
Product Category
Test Probes Test Probes Test Probes Test Probes Test Probes Test Probes Test Probes Test Probes Test Probes
制造商
Manufacturer
Global Specialties Global Specialties Global Specialties Global Specialties Global Specialties Global Specialties Global Specialties Global Specialties Global Specialties
RoHS Details Details Details Details Details Details Details Details Details
工厂包装数量
Factory Pack Quantity
1 1 1 1 1 1 1 1 1
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消