For complete specification data, visit our Web site at
www.bussmann.com
or call Bussmann Information Fax ~ 636.527.1450
5mm x 20mm Fuses
GMC Series
Medium Time Delay, Glass Tube
Description
• Medium time delay, low breaking capacity
• 5mm x 20mm physical size
• Glass tube, nickel-plated brass endcap construction
• Optional axial leads are .032" x 1.5" copper tinned
• Optional sleeve is flexible flouropolymer
(U.L. flammability rating VW-1)
• Designed to UL/CSA 248-14
ELECTRICAL CHARACTERISTICS
Rated Current % of Amp Rating
Opening Time
100%
None
63mA - 10A
135%
60 minutes maximum
200%
2 minutes maximum
Dimensions
mm
⁄
(inches)
5.54mm
(±.20)
38.10mm
0m
(±.38)
±
.3
Approvals
• UL Listed, Guide JDYX, File E75865, 63mA-6.3A
• UL Recognition, Guide JDYX2, File E75865, 7A-8A
• CSA Certified, Class 1422-01, File E65063, 63mA-6.3A
Ordering
• Specify product code, option code and packaging code
(±
±
0.5)
21.10mm
0m
(±.81)
81
5.2mm
(+0.1/-0.2)
.81 (REF)
38.10mm
0m
(±.38)
38
SPECIFICATIONS
Product Code
GMC-63mA
GMC-80mA
GMC-100mA
GMC-125mA
GMC-150mA
GMC-160mA
GMC-200mA
GMC-250mA
GMC-300mA
GMC-315mA
GMC-400mA
GMC-500mA
GMC-600mA
GMC-630mA
GMC-700mA
GMC-750mA
GMC-800mA
GMC-1A
GMC-1.25A
GMC-1.5A
GMC-1.6A
GMC-2A
GMC-2.5A
GMC-3A
GMC-3.15A
GMC-3.5A
GMC-4A
GMC-5A
GMC-6A
GMC-6.3A
GMC-7A
GMC-8A
GMC-10A
*
**
†
‡
Voltage
Rating
AC
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
250V
125V
125V
125V
125V
125V
125V
125V
125V
AC Interrupting
Rating*
250V
125V
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
35A
10,000A
100A
10,000A
100A
10,000A
100A
10,000A
100A
10,000A
100A
10,000A
100A
10,000A
100A
10,000A
-
10,000A
-
10,000A
-
10,000A
-
10,000A
-
10,000A
-
200A
-
200A
-
200A
Typical DC Cold
Resistance
(ohms)**
10.350
-
4.775
3.400
2.555
2.295
1.395
0.965
0.838
0.685
0.615
0.335
0.282
0.246
0.213
0.213
0.180
0.156
0.098
0.076
0.067
0.043
0.035
0.026
0.025
0.022
0.019
0.014
0.013
0.012
0.012
0.009
0.007
Typical
Pre-Arc I
2
t
AC†
0.0027
0.0050
0.0094
0.014
0.022
0.022
0.032
0.046
0.081
0.081
0.18
0.41
0.60
0.66
0.85
0.85
0.85
1.8
3.4
5.4
5.8
8.9
13
19
23
25
36
58
88
110
150
200
300
Maximum
Voltage
Drop (mV)‡
1400
1400
1200
1000
800
730
650
490
580
480
510
370
360
360
340
320
290
250
200
190
160
130
130
130
130
130
120
120
120
120
120
110
110
Interrupting ratings: Interrupting ratings for 63mA - 6.3A were measured at 70% - 80% power factor on AC. The interrupting ratings for 7A - 10A were measured at 100% power factor on AC.
DC Cold Resistance (Measured at <10% of rated current)
Typical Pre-Arching I
2
t (I
2
t was measured at listed interrupting rating and rated voltage)
Maximum Voltage drop (Voltage drop was measured at 20°C ambient temperature at rated current)