8 kV
Kilovac HC-2
HC-4
No Load Switching
Make & Break Load Switching
Features:
HC-2
Vacuum dielectric and copper contacts for
high current carry rating of 25 Amps
Not designed for power switching
Stable, low contact resistance
Meets requirements of MIL-R-83725
HC-4
Tungsten contacts for long life in power
switching applications
Vacuum dielectric for arc suppression when
making or breaking a load
Widely used in defibillator applications
Meets requirements of MIL-R-83725
Kilovac HC-6
Make Only
Features:
Tungsten contacts for switching high in-rush
loads
SF-6 gas-filled for capacitive discharge
applications
Ideal for ESD testing applications
Part Number
PRODUCT SPECIFICATIONS
Units
HC-2
SPDT
C
COIL DATA
HC-4
SPDT
C
10
8
-
-
-
15
-
-
-
500
-
-
0.02
6
6
50
55-2000
-55 to +125
2
1.4
HC-6
SPDT
C
10
8
-
-
-
8
-
-
-
500
-
-
0.5*
6
6
50
55-2000
-55 to +125
1
1.4
Nominal, Volts dc
Pickup, Volts dc, Maximum
Drop-Out, Volts dc
Coil Resistance (Ohms ±10%)
12
8
.5 - 5
80
26.5
16
1 - 10
335
115
80
5 - 50
6000
Contact Arrangement ..........................................................
Contact Form ........................................................................
Test Voltage (dc or 60Hz) ...................................................
Rated Operating Voltage
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Continuous Carry Current , Maximum
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance
Between Open Contacts .................................................
Open Contacts to Ground ..............................................
Contact Resistance, Maximum ...........................................
Operate Time, Maximum .....................................................
Release Time, Maximum .....................................................
Shock, 11 ms 1/2 Sine ........................................................
Vibration, 10 Gs Peak .........................................................
Operating Ambient Temperature Range ............................
Mechanical Life (Operations x 10
6
) ....................................
Weight, Nominal ..................................................................
* Contact resistance for gas-filled relays is measured at 28 Vdc, 1 amp
kV Peak
10
8
-
-
-
Ratings listed are for 25°C, sea level conditions
PART NUMBER SELECTION
Sample Part No.
HC -
Model
2
4
6
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
6
/12Vdc
A RMS
25
-
-
-
500
pF
-
-
ohms
ms
ms
Peak G's
Hz
o
0.01
6
6
50
55-2000
-55 to +125
2
1.4
C
Cycles
oz.
CII Technologies
/ P.O. Box 4422 / Santa Barbara, CA 93140 /
ph
805.684.4560 /
fax
805.684.9679
/
e-mail
info@kilovac.com /
website
www.ciitech.com
36