Medical Open Frame
65 Watts
PBM65 Series
•
T
HE
XP
ERTS
I
N
P
OWER
4000 VAC Isolation
•
Low Leakage Current
•
Meets Class B, EN55011 Conducted
•
Medical Safety Agency Approvals
•
Both Line and Neutral Fused
•
Fixed Switching Frequency
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Earth Leakage
Current
•
•
•
•
•
85-264 VAC
47-63 Hz
1.6 A max at 115 VAC
1.0 A max at 230 VAC
17 A max at 115 VAC
40 A max at 230 VAC
90 µA max at 115 VAC, 60 Hz
150 µA max at 230 VAC, 50 Hz
General
Efficiency
MTBF
Switching Frequency
Isolation Voltage
•
•
•
•
66% minimum for 5 V models
75% minimum for all others
400,000 hrs min MIL-HDBK-217F
42 kHz ±5 kHz
4000 VAC Input to Output
1500 VAC Input to Output
500 VAC Output to Ground
5.0 x 3.0 x 1.2”
127.00 x 76.20 x 30.48 mm
330 g approx (PCB format)
Size
Weight
•
•
Output
Output Voltage
Output Voltage
Adjustment
Output Power
Minimum Load
Line Regulation
Load Regulation
Ripple and Noise
Transient Response
•
•
•
•
•
•
•
•
5.1 to 28 VDC
±5%
65 Watts
No minimum load required
±0.5% max at full load
±2% typical
±1% pk-pk max (See Note 2)
4% maximum deviation, 500 µs
recovery time to within 1% for a
25% load change
±0.04%/°C
10 ms minimum at 110 VAC
112-132% with auto recovery
125-200% with auto recovery
Trip & restart with auto recovery
Compensates for up to 0.5 V drop
Environmental
Operating
Temperature
Cooling
Relative Humidity
Storage
Temperature
•
0 °C to +70 °C
Derate linearly from 100% load at
+50 °C to 50% load at +70 °C
Convection cooled
5-95% non-condensing
-40 °C to +85 °C
•
•
•
EMC & Safety
Safety Approvals
EMI/EMC
•
•
UL2601-1, CSA C22.2 No 601.1,
EN60601-1 CE Mark (LVD)
EN55011 (CISPR11) Class B and
FCC Part 18 Level B radiated &
conducted
EN61000-4-2, Level 3 air,
Level 2 contact, Perf Criteria A
EN61000-4-3, 3 V/m, Perf Criteria A
EN61000-4-4, Level 3, Perf Criteria A
EN61000-4-5, Level 3, Perf Criteria A
Temperature
Coefficient
Hold Up Time
Overvoltage
Protection
Overcurrent
Protection
Short Circuit
Protection
Remote Sense
•
•
•
•
•
•
ESD
Radiated Immunity
EFT/Burst
Surge
•
•
•
•
•
•
www.xpplc.com
sales@xpplc.com
AC-DC Power Supplies
OUTPUT VOLTAGE & CURRENT RATINGS
Maximum
Output Power
51 W
65 W
65 W
65 W
65 W
65 W
Notes
Output
Voltage
5.1 VDC
12.0 VDC
15.0 VDC
18.0 VDC
24.0 VDC
28.0 VDC
Output
Current
10.0 A
5.5 A
4.4 A
3.7 A
2.8 A
2.4 A
Total
Regulation
(1)
3%
2%
2%
2%
2%
2%
PBM65
Model
Number
PBM65US05
PBM65US12
PBM65US15
PBM65US18
PBM65US24
PBM65US28
•
1. Total regulation includes line and load regulation and set point accuracy.
2. Ripple and noise measured with 20 MHz bandwidth with 10 µF tantalum capacitor in parallel with a 0.1 µF ceramic capacitor.
Mechanical Details
Medical Open Frame 65 Watts PBM65 Series
P3 PIN CONNECTIONS
Pin
Function
1
Output 1
2
Output 1
3
Output 1
4
Return
5
Return
6
Return
NOTES:
1. Dimensions shown in inches (mm).
2. Tolerance 0.02 (0.5) maximum.
3. Input connector mates with molex housing 09-50-3031 and Molex 2878 series crimp terminal.
4. Output connector mates with molex housing 09-50-3061 and Molex 2878 series crimp terminal.
5. P4 is for sense connector mates with molex housing 22-01-1023 and molex 40445 series crimp terminal.
6. Loom kits with 300 mm wire available, order part number PBM65 LOOM.
7. For mating connectors only, order part number PBM65 CONKT.
8. Covers available, order part number PBM65 COVER.
9. Weight: 330 g (PCB format).
www.xpplc.com
sales@xpplc.com
Rev 3.0