Derating graphs are valid only for the shown part numbers.
If you need detailed derating-information about a part-number
not shown here please contact our technical support service
at info@recom-development.at
Ambient Temperature Range (°C)
Please Read Application Notes
P-71
www.recom-international.com
REV:0/2014
POWERLINE
DC/DC-Converter
Typical Characteristics
RP30-S_DE
Series
RP30-4805SE
Efficiency VS Output Load
92
90
89
88
87
86
85
84
80
78
76
74
RP30-4805SE
Efficiency VS Input Voltage
93
92
91
90
89
88
87
86
85
84
83
82
Efficiency (%)
Efficiency (%)
36
40
45
50
55
60
65
70
75
1
2
3
4
5
6
Intput Voltage (V)
Output Load (A)
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
12V nominal input
24V nominal input
48V nominal input
Under Voltage Lockout
12V input
24V input
48V input
Input Filter
(1)
Input Voltage Variation dv/dt
Input Surge Voltage (100 ms max.)
(Complies with ETS300 132 part 4.4)
12V Input
24V Input
48V Input
Input Reflected Ripple (nominal Vin and full load)
(3)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF
(7)
Remote OFF input current
Output Power
Output Voltage Accuracy (full Load and nominal Vin)
Voltage Adjustability
Minimum Load
Line Regulation (low line, high line at full load)
Single & Dual
Single
Dual
DC-DC ON
DC-DC OFF
Nominal input
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
DC-DC ON
DC-DC OFF
9-18VDC
18-36VDC
36-75VDC
9VDC
8VDC
17.8VDC
16VDC
36VDC
33VDC
L-C Type
5V/ms max
36VDC
50VDC
100VDC
30mAp-p
25ms typ.
Open or 3.0V < Vr < 12V
Short or 0V < Vr < 1.2V
2.5mA
30W max.
±1%
±10%
0%
±0.2%
±0.5%
continued on next page
RP30-E
P-72
REV: 0/2014
www.recom-power.com
POWERLINE
DC/DC-Converter
Specifications
(typical at nominal input and 25°C unless otherwise noted)
Load Regulation (25% to 100% full load)
Cross Regulation (Asymmetrical 25% <> 100% load)
Ripple and Noise (20MHz bandwith, with 1µF MLCC on output)
(Measured with a 1004pF/50V MLCC)
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
3.3V
5V
12V
15V
Over Load Protection (% of full load at nominal Vin)
Undervoltage Lockout
Short Circuit Protection
Efficiency
Isolation Voltage (rated for one minute)
Isolation Resistance
Isolation Capacitance
Operating Frequency
Approved to Safety Standards
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Over Temperature Protection
Thermal Impedance
(8)
Thermal Shock
Vibration
Relative Humidity
Case Material
Base Material
Potting Material
Weight
Packing Quantity
Dimensions
Conducted Emissions
(9)
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
MTBF
(2)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Natural convection
Single
Dual
Dual
Single 3.3, 5V
Single 12, 15V
Dual 5, 12, 15V
RP30-S_DE
Series
±0.5%
±1%
±5%
50mVp-p
75mVp-p
100mVp-p
±0.02%/°C max.
300µs
3.9V
6.2V
15V
18V
150% typ
See Application Notes
Hiccup, automatic recovery
see „Selection Guide“ table
1600VDC
1 GΩ min.
1000pF max.
300kHz typ.
UL 1950, EN60950
-40°C to +85°C(with derating)
RP30-E
+100°C
-55°C to +125°C
115°C typ.
10°C/Watt
8.24°C/Watt
MIL-STD-810D
10-55Hz, 10G, 30 Min. along X, Y and Z
5% to 95% RH
Nickel plated copper
Non-conductive black plastic
Epoxy (UL94-V0)
48g
Refer to App Notes for tube dimensions
5 pcs per Tube
50.8 x 40.6 x 10.2mm
Class A
Class A
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
Perf. Criteria B
1535 x 10
3
hours
Natural convection with Heat Sink
www.recom-international.com
REV:0/2014
P-73
POWERLINE
DC/DC-Converter
Notes :
RP30-S_DE
Series
1. An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current for 48V/24V models.
RECOM suggest: Nippon chemi-con KY series, 220µF/100V, ESR 90m
Ω.
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control pin voltage is referenced to negative input
8. Heat sink is optional and P/N: 7G-0011-C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips
(add suffix -HC). See Application Notes for heatsink details.
9. See application notes for Class B common mode filter suggestion.
Package Style and Pinning (mm)
50.80
10.20
dia.
1.0
5.6
40.60
Pin Connections
RP30-E
45.70
5
17.80
Bottom View
5.10
15.20
1
2
10.20
6
12.70
Pin #
1
2
4
5
6
7
8
Single
+Vin
-Vin
CTRL
No Pin
+Vout
-Vout
Trim
Dual
+Vin
-Vin
CTRL
+Vout
Com
-Vout
Trim
Pin Pitch Tolerance ±0.35 mm
7
4
10.20
8
17.80
External Output Trimming
Output can be externally trimmed by using the method
shown below. ( ) for dual output trim.
See Application Notes for details.
7(7)
Trim Up
R
U
8(8)
Trim Down
R
D
8(8)
6(5)
The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.
The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property.