RWS1000/1500-B/ME Series
1000W to 1500W Single Output Medical Power Supplies
Features
Cost Effective
Wide Range AC Input 85 - 265VAC
Enclosed Construction
Compact Sizes
Suitable for B & BF Rated Equipment
7 Year Warranty
Key Market Segments & Applications
Specifications
Model
AAC Input Voltage range (1)
DC Input Voltage range*
Inrush Current (100 / 200VAC)
Power Factor (100 / 200VAC)
Input Current (100/200VAC) (Typ)
Temperature Coefficient
Regulation
Overcurrent Protection
Overvoltage Protection
Hold Up Time (Typ at 100% load)
Leakage Current (max)
Remote Sense
Remote On/Off
DC Good, Fan Alarm
Parallel Operation
Series Operation
Operating Temperature
Storage Temperature
Operating Humidity (non condensing)
Storage Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Certifications
Line Dips
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (WxHxD)
RWS1000B/ME
VAC
VDC
A
-
A
%/°C
-
-
V
ms
mA
-
-
-
-
-
°C
°C
%RH
%RH
-
VAC
RWS1500B/ME
85 - 265VAC (47 - 63Hz)
120 - 340VDC*
60 / 60A
Meets EN61000-3-2 (0.98 / 0.95)
13 / 7A
19 / 10A
<0.02%/°C
See Model Selector
>105%, Constant Current Style. After 5s unit will shutdown
120-145% (115-125% for 48V), Cycle AC line to reset
20ms
<0.3mA
Yes
See options table. Apply external voltage to enable output voltage
See options table
See options table
Yes
-20 to +60°C, derate linearly to 60% load from 50 to 60°C
-30 to +75°C
20 - 90%RH
10 - 90%RH
Internal Fan, air intake from input/output terminals
Input to Ground 2kVAC (1xMoPP), Input to Output 4kVAC (2xMoPP),
Output to Ground 1.5kVAC (1xMoPP) for 1 min.
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz: 19.6m/s
2
(sweep 1 min) X, Y, Z for 1 hour
< 196.1 m/s
2
ES60601-1, CSA60601, EN60601-1, CE Mark
SEMI-F47 (200VAC input)
EN55011 / EN55032-A, FCC Class A, VCCI-A
IEC61000-4-2, -3, -4, -5, -6, -8, -11, IEC61000-6-2, EN60601-1-2
2,000g
3,000g
127 x 63 x 198mm
127 x 63 x 261mm
5 x 2.48 x 7.8”
5 x 2.48 x 10.28”
1,834,313
1,222,361
Seven Years
MΩ
-
-
-
-
-
-
g
mm
In
MTBF - Telcordia SR-332 issue 3** hours
Warranty
yrs
*Safety certified for AC input only
**24V output model, 25°C ambient, full load, 230VAC input
(1) Derate linearly to 80% load from 90 to 85VAC input
1-800-526-2324 • www.us.tdk-lambda.com/lp/
44
Disclaimer: us.tdk-lambda.com/lp/legal.htm
RWS1000/1500-B/ME Series
Output Ratings
Model
RWS1000B-12/ME
RWS1500B-12/ME
RWS1000B-15/ME
RWS1500B-15/ME
RWS1000B-24/ME
RWS1500B-24/ME
RWS1000B-36/ME
RWS1500B-36/ME
RWS1000B-48/ME
RWS1500B-48/ME
Voltage
12V
12V
15V
15V
24V
24V
36V
36V
48V
48V
Adjust Range
(V)
10.2-13.8V
10.2-13.8V
12.8-17.2V
12.8-17.2V
20.4-27.6V
20.4-27.6V
30.6-41.4
30.6-41.4
40.8-52.8
40.8-52.8
Max Current
(A)
84
125
67
100
42
63
28
42
21
32
Max Output
Power (w)
1008
1500
1005
1500
1008
1512
1008
1512
1008
1536
Load Reg
(mV)
96
96
120
120
144
144
216
216
288
288
Line Reg
(mV)
48
48
60
60
96
96
144
144
192
192
Ripple Noise
(mV)
150
150
150
150
180
180
250
250
300
300
Efficiency (typ) %
115/230VAC
82 / 85
81 / 85
82 / 85
82 / 85
85 / 88
85 / 88
85 / 88
85 / 88
85 / 88
85 / 88
Outline Drawing RWS 1000B
Outline Drawing RWS 1500B
Options (Contact Sales for availability)
Suffix
/CO2
/FO
/R
/RF
/RFO
Description
Double Sided Board Coating
Parallel Operation, DC Good and Fan Alarm Signals
Remote On/Off
Reverse Fan (Air exits over input/output terminals)
Remote On/Off, Parallel Operation, DC Good and Fan Alarm Signals
For Additional Information, please visit
us.tdk-lambda.com/lp/products/rwsb-series.htm
1-800-526-2324 • www.us.tdk-lambda.com/lp/
45
Revision p3: Dec 2017
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
TDK-Lambda
:
RWS1500B12/ME RWS1000B12/ME RWS1500B36/ME RWS1000B36/ME RWS1000B48/ME RWS1500B24/ME
RWS1500B15/ME RWS1000B24/ME RWS1000B15/ME RWS1500B48/ME