SL3010
INFRARED REMOTE CONTROL
TRANSMITTER RC-5
The SL3010 is intended as a general purpose (RC-5) infrared
remote control system for use where a low voltage supply and a large
debounce time are expected. The device can generate 2048 different
commands and utilizes a keyboard with a single pole switch for each
key. The command are arranged so that 32 systems can be addressed,
each
system containing 64 different commands. The keyboard
interconnection is illustrated by Fig.1.
•
•
•
•
Low voltage requirement
Single pin oscillator
Biphase transmission technique
Test mode facility
ORDERING INFORMATION
SL3010N Plastic
SL3010D SOIC
T
A
= -25° to 85° C
for all packages.
BLOCK DIAGRAM
PIN ASSIGNMENT
SLS
System Logic
Semiconductor
SL3010
PIN DESCRIPTION
PIN No
1
2
3-6
7
8
9-13
14
15-17
18
19
20
21-27
28
(I)
(IPU)
(ODN)
(OP3)
DESIGNATION
X7 (IPU)
SSM (I)
Z0-Z3 (IPU)
MDATA (OP3)
DESCRIPTION
sense input from key matrix
system mode selection input
sense inputs from key matrix
generated output data modulated with 1/2 the oscillator frequency at a 25%
duty factor
generated output information
scan drivers
ground (0V)
scan drivers
oscillator input
test point 2
test point 1
sense inputs from key matrix
voltage supply
DATA (OP3)
DR7-DR3 (ODN)
GND
DR2-DR0 (ODN)
OSC (I)
TP2 (I)
TP1 (I)
X0-X6 (IPU)
Vcc (I)
= input
= input with p-channel pull-up transistor
= output with open drain n-channel transistor
= output 3-state
FUNCTIONAL DESCRIPTION
Keyboard operation
Every connection of one X-input and one DR-output will be recognized as a legal key operation and will cause
the device to generate the corresponding code. The same applies to every connection of one Z-input to one DR-
output with the proviso that SSM must be LOW. When SSM is HIGH a wired connection must exist between a Z-
input and DR-output. If no connection is present the system number will not be generated. Activating two or
more X-inputs, Z-inputs or Z-inputs and X-inputs at the same time is an illegal action and inhibits further activity
(oscillator will not start).
When one X- or Z-input is connected to more than one DR-output, the last scan signal will be considered as legal.
The maximum value of the contact series resistance of the switched keyboard is 7KΩ.
Inputs
In the quiescent state the command inputs X0 to X7 are held HIGH by an internal pull-up transistor. When the
system mode selection (SSM) input is LOW and the system is quiescent, the system inputs Z0 to Z3 are also held
HIGH by an internal pull-up transistor. When SSM is HIGH the pull-up transistor for the Z-inputs is switched off,
in order to prevent current flow, and a wired connection in the Z-DR matrix provides the system number.
Outputs
The output signal DATA transmits the generated information in accordance with the format illustrated by Fig.2
and Tables 1 and 2. The code is transmitted using a biphase technique as illustrated by Fig.3. The code consists
of four parts:
•
Start part - 1.5 bits (2 x logic 1)
•
Control part - 1 bit
•
System part - 5 bits
•
Command part - 6 bits
The output signal MDATA transmits the generated information modulated by 1/12 of the oscillator frequency
with a 50% duty factor.
In the quiescent state both DATA and MDATA are non-conducting (3-state outputs).
The scan driver outputs DR0 to DR7 are open drain n-channel transistors and conduct when the circuit is
quiescent. After a legal key operation the scanning cycle is started and the outputs switched to the conductive
state one by one. The DR-outputs were switched off at the end of the preceding debounce cycle.
SLS
System Logic
Semiconductor
SL3010
Table 1
Command matrix (X-DR)
Code
no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
0
x
x
x
x
x
x
x
x
1
X-lines
2 3 4
5
6
7
0
x
1
x
DR-lines
2 3 4 5
6
7
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
5
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
Command bits
3
2
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
0
0
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
SLS
System Logic
Semiconductor
SL3010
Table 1
Command matrix (X-DR) (Continued)
Code
no.
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
0
1
X-lines
2 3 4
5
6
x
x
x
x
x
x
x
7
0
1
x
DR-lines
2 3 4 5
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
6
7
5
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Command bits
3
2
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
1
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Table 2
System matrix (Z-DR)
Code
no.
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
0
x
x
x
x
x
x
x
x
1
X-lines
2 3 4
5
6
7
0
x
1
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
DR-lines
2 3 4 5
6
7
4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
System bits
3
2
1
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
0
1
0
0
1
1
0
1
1
1
0
0
1
0
0
1
0
1
1
0
1
1
1
0
1
1
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
0
0
1
0
1
0
0
1
0
0
1
1
0
1
1
1
0
0
1
0
0
1
0
1
1
0
1
1
1
0
1
1
0
1
1
1
1
1
1
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
SLS
System Logic
Semiconductor
SL3010
MAXIMUM RATINGS
*
Symbol
V
CC
V
IN
V
OUT
I
IN
I
OUT
P
DO
P
DO
P
D
Tstg
Parameter
DC Supply Voltage (Referenced to GND)
DC Input Voltage (Referenced to GND)*
DC Output Voltage (Referenced to GND)*
DC Input Current
DC Output Current
Maximum Power Dissipation
OSC output
other outputs
Power Dissipation in Still Air
Storage Temperature
Value
-0.5 to +8.5
-0.5 to V
CC
+0.5
-0.5 to V
CC
+0.5
±10
±10
50
100
200
-65 to +150
Unit
V
V
V
mA
mA
mW
mW
mW
°C
*V
CC
+ 0.5 must not exceeed 9.0V..
*
Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
+Derating - Plastic DIP: - 10 mW/°C from 65° to 85°C
SOIC Package: : - 7 mW/°C from 65° to 85°C
RECOMMENDED OPERATING CONDITIONS
Symbol
V
CC
V
IH
V
IL
V
OUT
I
IN
I
OL
Parameter
DC Supply voltage (Reference to GND)
DC Input voltage (HIGH)
DC Input voltage (LOW)
DC Output Voltage (MDATA, DATA)
DC Input Current
DC Output Current (LOW)
pins 7,8
pins 9-13; 15-17
DC Output Current (MDATA, DATA)
Operating Temperature, All Package Types
Min
2.0
0.7V
CC
0
-
-
-
Max
7.0
V
CC
0.3V
CC
7.0
±10
0.6
0.3
-0.4
85
Unit
V
V
V
V
mA
mA
mA
o
I
OH
T
A
-
-25
C
This device contains protection circuitry to guard against damage due to high static voltages or electric
fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated
voltages to this high-impedance circuit. For proper operation, V
IN
and V
OUT
should be constrained to the range
GND≤(V
IN
or V
OUT
)≤V
CC
.
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or V ).
CC
Unused outputs must be left open.
SLS
System Logic
Semiconductor