Off-Line PWM Controllers with Integrated Power MOSFET
STR-A6000 Series
General Descriptions
The STR-A6000 series are power ICs for switching
power supplies, incorporating a MOSFET and a current
mode PWM controller IC.
The low standby power is accomplished by the
automatic switching between the PWM operation in
normal operation and the burst-oscillation under light
load conditions. The product achieves high
cost-performance power supply systems with few
external components.
Data Sheet
Package
DIP8
Not to Scale
Features
Lineup
•
Current Mode Type PWM Control
•
Brown-In and Brown-Out function
•
Auto Standby Function
No Load Power Consumption < 25mW
•
Operation Mode
Normal Operation ---------------------------- PWM Mode
Standby --------------------------- Burst Oscillation Mode
•
Random Switching Function
•
Slope Compensation Function
•
Leading Edge Blanking Function
•
Bias Assist Function
•
Audible Noise Suppression function during Standby
mode
•
Protections
・Overcurrent
Protection (OCP)*; Pulse-by-Pulse,
built-in compensation circuit to minimize OCP point
variation on AC input voltage
・Overload
Protection (OLP); auto-restart
・Overvoltage
Protection (OVP); latched shutdown
・Thermal
Shutdown Protection (TSD); latched shutdown
*STR-A60××HD has two types OCP
•
Electrical Characteristics
Products
STR-A605×M
STR-A607×M
STR-A605×H
STR-A606×H
STR-A606×HD
V
DSS
(min.)
650 V
800 V
650 V
700 V
700 V
f
OSC(AVG)
67 kHz
100 kHz
100 kHz
*STR-A60××HD has two types OCP
•
MOSFET ON Resistance and Output Power, P
OUT
*
Products
P
OUT
P
OUT
(Adapter)
(Open frame)
R
DS(ON)
(max.)
AC85
AC85
AC230V
AC230V
~265V
~265V
3.95 Ω 18.5 W
2.8 Ω
1.9 Ω
19.2 Ω
26 W
8W
14 W
21W
6W
31 W
40 W
13 W
21 W
28 W
9W
f
OSC(AVG)
= 67 kHz
STR-A6051M
STR-A6052M
STR-A6053M
STR-A6079M
STR-A6059H
STR-A6069H
6Ω
17 W
11 W
30 W 19.5 W
STR-A6069HD
22 W 17.5W
35 W 24.5 W
f
OSC(AVG)
= 100 kHz
Typical Application Circuit
BR1
VAC
C6
C1
D1
R1
PC1
P
C51
S
R52
C52 R53
U51
C2
D
R56
(-)
T1
D51
L51
VOUT
(+)
R54
R51
R55
C53
STR-A6061H
STR-A6061HD
STR-A6062H
STR-A6062HD
3.95Ω 20.5 W
2.8 Ω
23 W
25 W
15 W
18 W
20 W
35 W 23.5 W
38 W 26.5 W
40 W
28 W
D2
8
7
NC
5
VCC
R2
STR-A6063HD 2.3 Ω
R
A
C5
R
B
D/ST D/ST
*
The output power is actual continues power that is measured at
50 °C ambient. The peak output power can be 120 to 140 % of the
value stated here. Core size, ON Duty, and thermal design affect
the output power. It may be less than the value stated here.
U1
STR-A6000
S/OCP BR GND FB/OLP
1
2
3
4
R
C
C4
R
OCP
C3
PC1
C
Y
TC_STR-A6000_1_R1
Applications
•
Low power AC/DC adapter
•
White goods
•
Auxiliary power supply
•
OA, AV and industrial equipment
1
STR-A6000-DSE Rev.4.5
SANKEN ELECTRIC CO., LTD.
Jun. 20, 2021
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2008
STR-A6000 Series
Contents
General Descriptions ----------------------------------------------------------------------- 1
1. Absolute Maximum Ratings --------------------------------------------------------- 3
2. Electrical Characteristics ------------------------------------------------------------ 4
3. Performance Curves ------------------------------------------------------------------ 6
3.1
Derating Curves --------------------------------------------------------------- 6
3.2
Ambient Temperature versus Power Dissipation Curve ------------- 6
3.3
MOSFET Safe Operating Area Curves ---------------------------------- 7
3.4
Transient Thermal Resistance Curves ----------------------------------- 9
4. Functional Block Diagram ---------------------------------------------------------- 11
5. Pin Configuration Definitions ------------------------------------------------------ 11
6. Typical Application Circuit -------------------------------------------------------- 12
7. Package Outline ----------------------------------------------------------------------- 13
8. Marking Diagram -------------------------------------------------------------------- 13
9. Operational Description ------------------------------------------------------------- 14
9.1
Startup Operation ----------------------------------------------------------- 14
9.2
Undervoltage Lockout (UVLO) ------------------------------------------- 15
9.3
Bias Assist Function --------------------------------------------------------- 15
9.4
Constant Output Voltage Control ---------------------------------------- 15
9.5
Leading Edge Blanking Function ---------------------------------------- 16
9.6
Random Switching Function ---------------------------------------------- 16
9.7
Automatic Standby Mode Function-------------------------------------- 16
9.8
Brown-In and Brown-Out Function ------------------------------------- 17
9.8.1DC Line Detection --------------------------------------------------------- 17
9.8.2AC Line Detection --------------------------------------------------------- 18
9.9
Overcurrent Protection Function (OCP) ------------------------------- 19
9.10 Overload Protection Function (OLP) ----------------------------------- 20
9.11 Overvoltage Protection (OVP) -------------------------------------------- 20
9.12 Thermal Shutdown Function (TSD) ------------------------------------- 20
10. Design Notes --------------------------------------------------------------------------- 21
10.1 External Components ------------------------------------------------------- 21
10.2 PCB Trace Layout and Component Placement ----------------------- 22
11. Pattern Layout Example ------------------------------------------------------------ 24
12. Reference Design of Power Supply ----------------------------------------------- 25
Important Notes ---------------------------------------------------------------------------- 27
STR-A6000-DSE Rev.4.5
SANKEN ELECTRIC CO., LTD.
Jun. 20, 2021
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2008
2
STR-A6000 Series
1.
Absolute Maximum Ratings
Current polarities are defined as follows: current going into the IC (sinking) is positive current (+); and current coming
out of the IC (sourcing) is negative current (−).
Unless otherwise specified, T
A
= 25 °C, 7 pin = 8 pin.
Parameter
Symbol
Test Conditions
Pins
Rating
Units
Remarks
1.2
1.8
Drain Peak Current
(1)
I
DPEAK
Single pulse
8–1
2.5
3.0
4.0
I
LPEAK
=1.2A
I
LPEAK
=1.8A
I
LPEAK
=2A
A6079M
A6059H / 69H
/ 69HD
A6051M / 61H
/ 61HD
A6052M / 62H
/ 62HD
A6053M / 63HD
A6079M
A6059H / 69H
/ 69HD
A6061H / 61HD
A
7
24
46
8–1
47
56
62
72
86
1−3
2−3
2−3
4−3
4−3
5−3
−2 to 6
−0.3 to 7
1.0
−0.3 to 14
1.0
32
1.35
1.2
−20 to 125
−40 to 125
150
V
V
mA
V
mA
V
W
W
°C
°C
°C
mJ
Avalanche Energy
(2)(3)
E
AS
I
LPEAK
=2A
I
LPEAK
=2.2A
I
LPEAK
=2.3A
I
LPEAK
=2.5A
I
LPEAK
=2.7A
A6051M
A6062H / 62HD
A6052M
A6063HD
A6053M
S/OCP Pin Voltage
BR Pin Voltage
BR Pin Sink Current
FB/OLP Pin Voltage
FB/OLP Pin Sink Current
VCC Pin Voltage
MOSFET Power
Dissipation
(4)
Control Part Power
Dissipation
Operating Ambient
Temperature
(6)
Storage Temperature
Channel Temperature
V
S/OCP
V
BR
I
BR
V
FB
I
FB
V
CC
P
D1
P
D2
T
OP
T
stg
T
ch
(5)
8–1
5–3
—
—
—
(1)
(2)
Refer to 3.3 MOSFET Safe Operating Area Curves
Refer to Figure 3-2. Avalanche Energy Derating Coefficient Curve
(3)
Single pulse, V
DD
= 99 V, L = 20 mH
(4)
Refer to Figure 3-3. Ambient Temperature Versus Power Dissipation Curve
(5)
When embedding this hybrid IC onto the printed circuit board (cupper area in a 15 mm × 15 mm)
(6)
The recommended internal frame temperature, T
F
, is 115°C (max.)
STR-A6000-DSE Rev.4.5
SANKEN ELECTRIC CO., LTD.
Jun. 20, 2021
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2008
3
STR-A6000 Series
2.
Electrical Characteristics
Current polarities are defined as follows: current going into the IC (sinking) is positive current (+); and current
coming out of the IC (sourcing) is negative current (−).
Unless otherwise specified, T
A
= 25 °C, V
CC
= 18 V, 7 pin = 8 pin.
Test
Parameter
Symbol
Pins
Min.
Typ.
Max.
Units
Remarks
Conditions
Power Supply Startup Operation
Operation Start Voltage
Operation Stop Voltage
(1)
Circuit Current in Operation
Startup Circuit Operation
Voltage
Startup Current
Startup Current Biasing
Threshold Voltage
Normal Operation
Average Switching
Frequency
Switching Frequency
Modulation Deviation
Maximum ON Duty
Minimum ON Time
Protection Function
Leading Edge Blanking Time
OCP Compensation
Coefficient
OCP Compensation ON Duty
OCP Threshold Voltage at
Zero ON Duty
OCP Threshold Voltage at
36% ON Duty
OCP Threshold Voltage in
Leading Edge Blanking Time
Maximum Feedback Current
Minimum Feedback Current
FB/OLP pin Oscillation Stop
Threshold Voltage
OLP Threshold Voltage
OLP Operation Current
OLP Delay Time
(1)
V
CC(ON)
V
CC(OFF)
I
CC(ON)
V
ST(ON)
I
STARTUP
V
CC(BIAS)
V
CC
= 12 V
5−3
5−3
5−3
8−3
V
CC
= 13.5 V
5 − 3
I
CC
= − 100 µA
13.8
7.3
—
—
− 3.7
8.5
15.3
8.1
—
38
− 2.5
9.5
16.8
8.9
2.5
—
− 1.5
10.5
V
V
mA
V
mA
V
5−3
f
OSC(AVG)
Δf
D
MAX
t
ON(MIN)
8−3
8−3
8−3
8−3
60
90
—
—
77
—
—
—
—
—
—
—
0.70
0.81
1.32
− 340
− 30
0.85
7.3
−
54
67
100
5
8
83
540
470
74
110
—
—
89
—
—
—
—
—
—
—
0.86
0.99
1.78
− 150
−7
1.05
8.9
600
82
A60××M
kHz
A60××H / HD
A60××M
kHz
A60××H / HD
%
ns
A60××M
A60××H / HD
t
BW
—
—
—
1−3
1−3
1−3
V
CC
= 12 V
340
280
20
33
36
0.78
0.9
1.55
− 230
− 15
0.95
8.1
300
68
A60××M
ns
A60××H / HD
DPC
D
DPC
V
OCP(L)
V
OCP(H)
V
OCP(LEB)
I
FB(MAX)
I
FB(MIN)
V
FB(STB)
V
FB(OLP)
I
CC(OLP)
t
OLP
V
CC
= 12 V
mV/μs
%
V
V
V
µA
µA
V
V
µA
ms
A60××M
A60××H / HD
A60××HD
4−3
4−3
4−3
4−3
5−3
—
V
CC(BIAS)
> V
CC(OFF)
always.
STR-A6000-DSE Rev.4.5
SANKEN ELECTRIC CO., LTD.
Jun. 20, 2021
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2008
4
STR-A6000 Series
Parameter
FB/OLP Pin Clamp Voltage
Brown-In Threshold Voltage
Brown-Out Threshold
Voltage
BR Pin Clamp Voltage
BR Function Disabling
Threshold
OVP Threshold Voltage
Latch Circuits Holding
Current
(2)
Thermal Shutdown Operating
Temperature
MOSFET
650
Drain-to-Source Breakdown
Voltage
Drain Leakage Current
V
DSS
8–1
8–1
700
800
I
DSS
—
—
—
On Resistance
R
DS(ON)
I
DS
= 0.4A
Symbol
V
FB(CLAMP)
V
BR(IN)
V
BR(OUT)
V
BR(CLAMP)
V
BR(DIS)
V
CC(OVP)
I
CC(LATCH)
T
j(TSD)
Test
Conditions
Pins
4−3
2−3
2−3
2−3
2−3
5−3
Min.
11
5.2
4.45
6
0.3
26
—
135
Typ.
12.8
5.6
4.8
6.4
0.48
29
700
—
Max.
14
6
5.15
7
0.7
32
—
—
Units
V
V
V
V
V
V
μA
°C
Remarks
V
CC
= 9.5 V
5−3
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
300
19.2
6
3.95
2.8
2.3
1.9
250
400
ns
ns
Ω
μA
V
A605×
A606×
A607×
A6079M
A6059H / 69H
/ 69HD
A6051M / 61H
/ 61HD
A6052M / 62H
/ 62HD
A6063HD
A6053M
8−1
—
—
—
—
—
—
Switching Time
Thermal Resistance
Channel to Case Thermal
Resistance
(3)
t
f
8–1
A6053M
θ
ch-C
—
—
—
22
°C/W
(2)
A latch circuit is a circuit operated with Overvoltage Protection function (OVP) and/or Thermal Shutdown function
(TSD) in operation.
(3)
θ
ch-C
is thermal resistance between channel and case. Case temperature (T
C
) is measured at the center of the case top
surface.
STR-A6000-DSE Rev.4.5
SANKEN ELECTRIC CO., LTD.
Jun. 20, 2021
https://www.sanken-ele.co.jp/en
© SANKEN ELECTRIC CO., LTD. 2008
5