首页 > 器件类别 > 传感器 > 传感器硬件与配件

T63353

传感器硬件与配件 Replacable RH sensor for T8700 and T8000-H

器件类别:传感器    传感器硬件与配件   

厂商名称:Amphenol(安费诺)

厂商官网:http://www.amphenol.com/

下载文档
T63353 在线购买

供应商:

器件:T63353

价格:-

最低购买:-

库存:点击查看

点击购买

器件参数
参数名称
属性值
厂商名称
Amphenol(安费诺)
产品种类
传感器硬件与配件
系列
T6335
工厂包装数量
1
文档预览
®
Telaire
Accessories
Calibration Kits,
Enclosures, Software,
Cables
Calibration Kits
The Calibration Kit Model T2075NG includes all of the
necessary components for calibrating the Telaire
®
7001
and Ventotstat 8000 and 8100 series models. The kit is
housed in a carrying case with only one replacement
part (calibration gas (not supplied)) required. A 16
liter gas bottle (not supplied) can perform up to 20
calibrations. Calibration Kit Model T2076NG calibrates
the Vaporstat 9002.
CO2 View is a Windows based program that interfaces
with the 7000 series. This easy to use program displays
and graphs real-time CO
2
levels at a user adjustable
interval.
2080 CO
2
View Logging Software
UIP T2090
Modify your 8000 series (T8100, T8200, T8300).
Accessory Enclosures
Telaire offers four enclosures to expand the Ventostat
and Vaporstat installation options: Model T1508
Aspiration Box, Model T1505 Splash Resistant
Enclosure, and Model T1551 and T1552 Outdoor Air
Enclosures.
7001 Accessories
The Telaire 7001 hand held CO
2
and temperature
monitor is equipped with an output for recording data.
The cable, Model T2070, can be used with devices that
accept a 0 to 4V signal.
A relative humidity and datalogging kit with graphing
software, Model T2077, is available for long term
monitoring.
Part 62933 is an adapter for international operation.
Software
Windows based VG Graphing Software allows you
to easily download your IAQ measurements and
customize graphs.
Amphenol
Advanced Sensors
Calibration Kits
T2075NG and T2076NG
Calibration Process
The calibration is simple and can be done in just a few
minutes. Each CO
2
model has a calibration process
similar to the following:
Connect the tubing assembly to the sensor and
connect the regulator to the gas bottle.
Initiate the calibration process by using the sensor
buttons and display.
The process is automatically run by the sensor and
will signal upon completion.
Last, disconnect the tubing and gas regulator.
The illustration shows the complete set-up
for calibrating a sensor with display.
T2075NG Components
The Calibration Kit Model T2075NG includes:
Instruction sheet
Tubing assembly
Gas regulator with gauge
Carrying case.
Calibrates the following models:
Ventostat 8000 and 8100 Series
Telaire 7000 Series
Use in conjunction with UIP software for T8000 series
(T8100, T8200, T8300)
*Nitrogen gas not included.
Requires disposable gas tank: CGA600, 99.95%
Nitrogen 20 bar fill pressure, approximately one liter.
T2076NG Components
The Calibration Kit Model T2076NG includes:
Instruction sheet
Tubing assembly
Gas regulator with gauge
Carrying case.
Flow Meter
Calibrates the following models:
Vaporstat 9002
*Nitrogen gas not included.
Requires disposable gas tank: CGA600, 99.95%
Nitrogen 20 bar fill pressure, approximately one liter.
Enclosures
Specifications
Enclosures are compatible with all Ventostat 8000
series (except the 8003 and 8009) and Vaporstat 9002
models.
Tubing on 1508 Only
Pin Designations
1. Not Used
2. Not Used
3. Relay Norm Open
4. Relay Common
5. Relay Norm Closed
6. 4-20mA Output
7. Signal Ground
8. 0-10V Output
Pin Designations
1. AC+ / DC+
2. AC- / GND
P ower R equirements
18-36 VAC rms or
18-42 VDC
100 mA P eak,
70 mA avg @ 24 VDC
T1508 Aspiration Box
The Model 1508 is designed for in-duct sampling of
CO
2
concentrations at flow rates greater than 400
fpm. Clear cover allows for observation of the sensor.
Enclosure is screwed to the duct with probe inserted
into airstream. Air sampling probe is 1 in (25.4 mm)
diameter and 8 in (203.2 mm) long. Enclosure (ABS
plastic) has knockouts for conduit connection. CO
2
Sensor not included.
Mounting Bracket
(Pre-Installed on 1551)
Any of the Ventostat
8000 Series Sensors
Cover
Cover Removed
Spouts on
1505 and 1551 Only
Extension Tube
on 1508 Only
T1505 Splash Resistant Enclosure
The Model 1505 is designed to protect the sensor
in damp or wet environments which might occur in
agricultural, industrial or food processing environments.
This enclosure (ABS plastic) is designed to protect the
sensor from dripping or sprayed water. The transparent
cover allows for viewing of the sensor/display. Four
diffusion ports allow for entry of CO
2
. Knockouts are
provided for conduit connection. Response time of
the sensor is slowed to approximately 30 minutes
to measure a 90% step change in concentrations.
Enclosure is designed to screw directly to a wall. CO
2
sensor not included.
6.5 in (165.1 mm)
7 in
(177.8 mm)
1.13 in (28.7 mm)
1.13 in (28.7 mm) and 1.7in (43.18 mm)
0.88 in (22.35 mm)
3.75 in (95.25 mm)
4.25 in (107.95 mm)
3.5 in (88.9 mm)
10.5 in (266.7mm)
7 in (177.8 mm)
T1552 Outside Air Enclosure
The Model 1552 is a rugged weatherproof enclosure
(ABS plastic), designed to allow the 8000 series sensor
to operate in an outdoor environment and/or where
ambient temperatures are below freezing. The 1552 is
ideal for monitoring outside air or CO
2
as a surrogate
for combustion fumes in parking garages, tunnels and
loading docks. This enclosure features a temperature
control circuit and internal heaters to maintain the
sensor within its normal operating temperature range,
even if temperatures outside the enclosure are as
low as -20°F (-29°C). Four diffusion ports allow for
entry of CO
2
. Response time of the sensor is slowed
to approximately 30 minutes to measure a 90% step
change in concentrations. Enclosure is designed to
screw directly to a wall. CO
2
sensor not included. Power
consumption is 24V, 1.5 Amp (max), and includes the
Ventostat 8000 series.
T1551 Outside Air Enclosure
The Model 1551 is a rugged weatherproof enclosure
(ABS plastic), designed to allow the 8000 series sensor
to operate in an outdoor environment and/or where
ambient temperatures are below freezing. The 1551 is
ideal for monitoring outside air or CO
2
as a surrogate
for combustion fumes in parking garages, tunnels and
loading docks. This enclosure features a temperature
control circuit and internal heaters to maintain the
sensor within its normal operating temperature range,
even if temperatures outside the enclosure are as
low as –20°F (-29°C). Four diffusion ports allow for
entry of CO
2
. Response time of the sensor is slowed
approximately 30 minutes to measure a 90% step
change in concentrations. Enclosure is designed to
screw directly to a wall. CO
2
sensor not included.
Power Consumption
24V, 1.5 Amp (maximum) – including sensor
Software
T2072 and T2080
Software Compatibility
Windows 7
Product Supporting
Telaire 7001, all 8000 Series Products, 6003 Module
Functionality
Log and Graph CO
2
Levels (Sequential Record,
No Time Stamp)
Store Logged Files to a .TXT format for use with
other programs
Perform Zero and Span Calibration On Telaire’s 8000,
7001 and 6000 series sensors
Sample of the Display During “Real-time” Graphing
Connection Port
PC RS-232 Port, Telaire Product RJ45 Connector
(Cable P/N 62285 available)
62285 Connection Cable
Telaire Part No. 62285
Graphing Adjustments
Sample Time Interval
Number of Measurements Displayed
Display Maximum/Minimum
Display Mean
Display Standard Deviation
Display Best Fit Line
The software features:
Altitude adjustment for maximum accuracy
performance
Analog output adjustment
Single point and span gas calibration
Turn on and off ABC Logic™
Change temperature display units
Graphing and logging of CO
2
, temperature and %RH
(H Versions only)
The software can be used by distributors to make
modifications to the Ventostat prior to shipping to
the customer, as well as to make adjustments in the
field. The USB cable supplies power to the Ventostat,
negating the need for a separate power supply.
The T2090 UIP software kit is supplied with a USB-to-
Ventostat cable and software CD.
Ventostat UIP Software (T2090)
The Ventostat UIP software allows you to modify the
standard settings on the T8100, T8200 and T8300
series products.
Amphenol
Advanced Sensors
www.telaire.com
www.amphenol-sensors.com
© 2014 Amphenol Corporation. All Rights Reserved. Specifications are subject to change without notice.
Other company names and product names used in this document are the registered trademarks or
trademarks of their respective owners.
AAS-920-318B-04/2014
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Amphenol
:
T2070 T2077 T2080 T1505 T2090 T1552 T62285 T63353 T62270
查看更多>
参数对比
与T63353相近的元器件有:T2070、T62270。描述及对比如下:
型号 T63353 T2070 T62270
描述 传感器硬件与配件 Replacable RH sensor for T8700 and T8000-H 传感器硬件与配件 3 ft V output cbl RJ-45 传感器硬件与配件 AC Adapter T7001
厂商名称 Amphenol(安费诺) Amphenol(安费诺) Amphenol(安费诺)
产品种类 传感器硬件与配件 传感器硬件与配件 传感器硬件与配件
系列 T6335 Telaire Accessories T6227
工厂包装数量 1 1 1
关于一些无线定位设备不用GPRS传输数据的疑问
请教大神们,最近市场上有不少GPS定位设备,一般都是将GPS信息通过GPRS传输到对应的手机平台上,...
xuhui246 嵌入式系统
这么晚了,不知道还有没有懂锁相环的大神在……
1.如图1。我是想用锁相环锁定5K的差频。输入为12M,压控输出理论上是11.995M。 2.实际出...
城边草 模拟电子
第四篇 GD32L23x定时器的使用
GD32L23x定时器的使用 呼吸灯是一个很常见的LED点亮模式,显示的效果也很好看。...
xiaoli2018 GD32 MCU
意法半导体推出新型2-Kbit多功能资产跟踪专用远距离RFID芯片
全球领先的串行非易失性存储器供应商之一的意法半导体(纽约证券交易所:STM)今天推出两款新的204...
frozenviolet 汽车电子
热电偶分度表重发
不好意思,刚才那个没有发送成功! 热电偶分度表重发 谢谢 回复:热电偶分度表重发 好东西 谢谢 希望...
chenyu_lijun 测试/测量
【热心的软件从业人员请进】请教软件工程专业方向选择的问题
亲爱的哥哥姐姐们,耽误您一点时间,看看您有没有时间帮忙想一下这个问题,我希望能从您这里听些建议。 ...
liyanqing611 嵌入式系统
热门器件
热门资源推荐
器件捷径:
00 01 02 03 04 05 06 07 08 09 0A 0C 0F 0J 0L 0M 0R 0S 0T 0Z 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 1H 1K 1M 1N 1P 1S 1T 1V 1X 1Z 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 2G 2K 2M 2N 2P 2Q 2R 2S 2T 2W 2Z 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 3G 3H 3J 3K 3L 3M 3N 3P 3R 3S 3T 3V 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4M 4N 4P 4S 4T 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5E 5G 5H 5K 5M 5N 5P 5S 5T 5V 60 61 62 63 64 65 66 67 68 69 6A 6C 6E 6F 6M 6N 6P 6R 6S 6T 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7M 7N 7P 7Q 7V 7W 7X 80 81 82 83 84 85 86 87 88 89 8A 8D 8E 8L 8N 8P 8S 8T 8W 8Y 8Z 90 91 92 93 94 95 96 97 98 99 9A 9B 9C 9D 9F 9G 9H 9L 9S 9T 9W
需要登录后才可以下载。
登录取消