Special Purpose Fuses
2.25"
7/8"
0.263"
0.630"
0.423"
3/4"
LGR/LMF In-Line Fuses and LHR Holder
0.50"
0.50"
Knock-out Hole
Keyhole Punch
LGR Fuses
Fast Acting • 300 VAC
2.25"
Specifications
Voltage Rating:
7/8"
Maximum Interrupting Rating:
Approvals:
0.423"
Used as in-line protection for
fluorescent fixtures, this fast
acting fuse is ideal for increasing
3/4"
the safety and reliability of lighting
0.50"
fixtures.
300 volts AC
10,000A
Standard 248-14,
0.630"
UL Listed (File No: E10480)
CSA Certified (File No: LR29862)
0.263"
0.50"
0.610"
Knock-out Hole
12
Keyhole
Ampere Ratings
Punch
⁄
1
1
1
⁄
2
1.82"
1
6
⁄
10
2
2
1
⁄
2
3
4
5
6
7
8
9
10
12
15
Example part number (series & amperage): LGR 1
1
⁄
2
0.610"
LMF Fuses
Time-Delay • 300 VAC
0.610"
1.82"
Perfect for use in lighting systems,
this 300 VAC time-delay fuse
is designed to handle ballast
1.82"
transformer in-rush currents.
Specifications
Voltage Rating:
Maximum Interrupting Rating:
Approvals:
300 volts AC
10,000A
Standard 248-14,
UL Listed (File No: E10480)
CSA Certified (File No: LR29862)
Special Purpose Fuses
Ampere Ratings
0.610"
⁄
12
⁄
6 10
⁄
3 10
8 10
⁄
1
1
1
⁄
4
1
6
⁄
10
2
2
1
⁄
2
2
8
⁄
10
3
3
2
⁄
10
4
5
6
1
⁄
4
7
8
10
1.82"
Example part number (series & amperage): LMF 2
1
⁄
2
LHR Fuse Holder
Used as in-line protection for
fluorescent fixtures, the Littelfuse
LGR and LMF series fuses and LHR
holder offer increased safety and
reliability to lighting systems. On a
277 volt system, a fault occurring
in an unfused fixture could take out
the entire branch circuit affecting
2.25"
as many as 100 fixtures. This could
cause safety problems as well as
shut down operations.
By individually fusing fixtures, these
problems will be avoided. The
0.50"
added benefits of this is the ability to quickly identify the problem fixture
and reduce the repair time.
Fuse holders are rated up to 10 amperes at 300 volts and are equipped
with 7" 18 AWG leads. Order part number LHR 000 for two leads, and
part number LHR 001 for one lead with the other terminal used for
insertion of 18 AWG ballast lead.
Specifications
2.25"
7/8"
Voltage Rating:
Ampere Rating:
Approvals:
Flammability Rating:
Example part number:
0.50"
300 volts AC
LHR 000: 10A
LHR 001: 10A
UL Recognized
0.50"
94VO
LHR 000
3/4"
0.423"
Knock-out Hole
Knock-out Hole
Keyhole P
Mounting Information
7/8"
LHR 001/LHR 000 will fit keyhole punch or
0.875" knock-out hole. Anti-rotation feature is
3/4"
provided when used with keyhole punch.
0.50"
0.263"
0.630"
0.423"
A “U-shaped” clip is available for
Knock-out Hole
panel mount-
ing (packaged 10 clips per bag): Order part
number LHR OCA.
0.610"
Keyhole Punch
Keyhole Punch
2.25"
3/4"
1.82"
0.50"
0.50"
© 2005 Littelfuse
•
POWR-GARD
™
Products Catalog
www.littelfuse.com
109