760105346 | P-036-LN-5K-F12BK/25D
LazrSPEED® Indoor/Outdoor, Single Jacket All-Dielectric, Plenum Rated,
Gel-Free, Stranded Loose Tube Cable, PVDF jacket that provides increased
resistance to jet fuels, oils, and many chemicals
Product Classification
Portfolio
Product Type
Regional Availability
CommScope®
Fiber indoor/outdoor cable
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
Cable Qualification Standards
ANSI/ICEA S-104-696 | EN 187105 | Telcordia GR-409
Representative Image
General Specifications
Construction Type
Cable Type
Subunit Type
Non-armored
Stranded loose tube
Gel-free
Construction Materials
Fiber Type Solution
Total Fiber Count
OM4, LazrSPEED® 550
36
page 1 of 3
March 26, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760105346 | P-036-LN-5K-F12BK/25D
Fiber Type
Fiber Type, quantity
Fibers per Subunit, quantity
Jacket Color
Jacket UV Resistance
OM4, LazrSPEED® 550
36
12
Black
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
Cable Weight
Diameter Over Jacket
Filler, quantity
Subunit, quantity
2.50 mm | 0.10 in
92.0 kg/km | 62.0 lb/kft
9.70 mm | 0.38 in
2
3
Physical Specifications
Minimum Bend Radius, loaded
Minimum Bend Radius, unloaded
14.6 cm | 5.7 in
9.7 cm | 3.8 in
Tensile Load, long term, maximum
800 N | 180 lbf
Tensile Load, short term, maximum
2700 N | 607 lbf
Vertical Rise, maximum
888.0 m | 2913.0 ft
Flame Test Specifications
Flame Test Listing
Flame Test Method
NEC OFNP (ETL) and c(ETL)
NFPA 262
Environmental Specifications
Environmental Space
Installation Temperature
Operating Temperature
Storage Temperature
Plenum
-30 °C to +70 °C (-22 °F to +158 °F)
-40 °C to +70 °C (-40 °F to +158 °F)
-40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression
Compression Test Method
Flex
Flex Test Method
Impact
Impact Test Method
Strain
125 lb/in | 22 N/mm
FOTP-41 | IEC 60794-1 E3
35 cycles
FOTP-104 | IEC 60794-1 E6
2.17 ft lb | 2.94 N-m
FOTP-25 | IEC 60794-1 E4
See long and short term tensile loads
page 2 of 3
March 26, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018
760105346 | P-036-LN-5K-F12BK/25D
Strain Test Method
Twist
Twist Test Method
Water Penentration
Water Penentration Test Method
FOTP-33 | IEC 60794-1 E1
10 cycles
FOTP-85 | IEC 60794-1 E7
24 h
FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze
Cable Freeze Test Method
Heat Age
Heat Age Test Method
Low High Bend
Low High Bend Test Method
Temperature Cycle
Temperature Cycle Test Method
-2 °C | 28 °F
FOTP-98 | IEC 60794-1 F15
-40 °C to +85 °C (-40 °F to +185 °F)
IEC 60794-1 F9
-30 °C to +60 °C (-22 °F to +140 °F)
FOTP-37 | IEC 60794-1 E11
-40 °C to +70 °C (-40 °F to +158 °F)
FOTP-3 | IEC 60794-1 F1
Regulatory Compliance/Certifications
Agency
RoHS 2011/65/EU
ISO 9001:2015
Classification
Compliant
Designed, manufactured and/or distributed under this quality management system
Included Products
CS -5K-LT (Product Component—not orderable)
—
LazrSPEED ® 550 OM4 Bend-Insensitive Multimode Fiber
CS-5K-
Component—
LazrSPEED®
Bend-
* Footnotes
Operating Temperature
Specification applicable to non-terminated bulk fiber cable
page 3 of 3
March 26, 2019
©2019 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 19, 2018