DC/DC Converter; Product Weight (grams): 13; Input voltage min (V): 18; Input voltage max (V): 75; Output voltage min: 24; Output voltage max: 24; Output voltage dual assymetric (y/n): Single; Output Power (W): 6; Max Output current (A): 0.25; Efficiency (%): 84; Max Capacitive load (µF): 470; Package type: DIP24; Mounting: PCB; W (in): 0.8; L (in): 1.24; H (in): 0.4; W (mm): 20.3; L (mm): 31.6; H (mm): 10.2; Min Operating temperature: -40; Max operating temperature (°C): 85; Isolation (VDC): 6000; EMC compliance 1: EN 55022 Class A; EMC compliance 2: EN 55022 Class B; Case material: Plastic (flammability to UL 94V-0) ; Application 4 (building automation/IoT): 1; Application 5 (Industrial): 1; MTBF (h): 1000000; Derating : 71; Voltage Accuracy (%): ±3; Line Regulation (% of Vin): ±0.5; Load Regulation %: ±0.5; Ripple & Noise (mV p-p): 120; Switching Frequency typ (KHz): 300; Short circuit protection: Continuous
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load
unless otherwise specified.
Environment Specifications
Test
Vibration
Parameters
1500VDC Isolated models
3000 & 6000VDC Isolated models
Conditions
IEC/EN 61373 Category 1, class B
10-55Hz, 2g, 30min, every axis tested
Safety Specifications
Parameters
Approval
UL60950-1 for 1.5 and 3KV isolated models
Design to meet EN50155 for 1.5KV isolated models
Design to meet EN60601-1 3
rd
edition, 2xMOPP, Type CF applied part for 6KV isolated models
CISPER32/EN55032, class A, (without external component)
EMI - Conducted and radiated
class B, for 1.5 and 3KV isolated models (with the recommended EMC circuit part A)
emission
EN50121-3-2 for 1.5KV isolated models (with the recommended EMC circuit part A)
EN55016-2-1 for 1.5KV isolated models (with the recommended EMC circuit part A)
IEC61000-4-2, contact ±4KV, Criteria B for 1.5 and 3KV isolated models
Electrostatic Discharge Immunity
IEC61000-4-2, contact ±6KV, Criteria B for 6KV isolated models
EN50121-3-2, contact ±6KV, Air ±8KV, Criteria A for 1.5KV isolated models
IEC61000-4-3, 10V/m, Criteria A for 1.5 and 3KV isolated models
RF, Electromagnetic Field Immunity
EN50121-3-2, 20V/m, Criteria A for 1.5KV isolated models
Standards
IEC61000-4-4, ±2KV, Criteria B, (with the recommended EMC circuit part B)
Electrical Fast Transient/Burst
EN50121-3-2, ±2KV, Criteria A for 1.5KV isolated models (with the recommended
Immunity
EMC circuit part B)
IEC61000-4-5, ±2KV, Criteria B, (with the recommended EMC circuit part B)
Surge Immunity
EN50121-3-2, L-L ±1KV, Criteria A for 1.5KV isolated models (with the
recommended EMC circuit part B)
IEC61000-4-6, 3Vrms, Criteria A
RF, Conducted Disturbance Immunity
EN50121-3-2, 10Vr.m.s, Criteria A for 1.5KV isolated models