CA
Typical Applications
Telecommunication
Wireless Application
TCXO
Features
Mechanical Control (internal Trimmer)
Standard 4-Pin DIP Package
Frequency Range
Frequency Stabilities
Parameter
Code I
1 MHz – 35 MHz
Frequency stability
Operating temp range
vs. Operating temperature range
15
17
18
19
13
38
39
40
±
5.0 ppm
±
2.5 ppm
±
5.0 ppm
±
2.5 ppm
±
1.5 ppm
±
5.0 ppm
±
2.5 ppm
±
1.5 ppm
Value
-30....+75°
-20....+70°C
-10....60°C
Parameter
Condition
vs. Supply voltage change
vs. Load change
vs. Aging / year
< ± 0.5 ppm
< ± 0.3 ppm
< ± 1.0 ppm
Code II
Value
V
s
± 5%
Load ± 5%
Frequency Tuning
Parameter
Condition
Mechanical (No EFC)
Blank
Electrical freq. control (EFC)
Voltage range (Vc)
Pulling slope
U
>
±
3.0 ppm
> ± 5.0 ppm
0.5 V to 4.5 V
Positive
Value
(internal trimmer)
Note 1
@ V
S
=5V
RF Output
Parameter
Code III
Condition
Signal
Load
Duty cycle
Signal
Load
Output power
06
07
HCMOS
15pF ± 10%
40/60%
Clipped sinewave
20kΩ || 5pF
> 1 V
PP
Value
Note 2
@ Vc/2
Frequency >9.6 MHz
@ 20kΩ || 5pF
Condition
Supply Voltage
Parameter
Supply voltage (V
s
)
Power consumption steady state
Additional parameters
Parameter
Frame Specification
5V ± 5%
< 3 mA
< 20mA
Clipped Sinewave
HCMOS
Value
Condition
TQA 9000
Corning Frequency Control • Worldwide Data Book 2001
v1.0.2000-11-02
Corning Frequency Control Inc.
• 100 Watts Street • Mt. Holly Springs, PA 17065 • Tel 1-717-486-3411 • Fax 1-717-486-5920 • www.corningfrequency.com
Tele Quarz GmbH & Co. KG
• Landstrasse • D-74924 Neckarbischofsheim, Germany • Tel +49-7268-801-0 • Fax +49-07268-801-281 • www.telequarz.de
1/2
CA
Enclosure
Drawing
TCXO
all Units in mm
12,2max.
7,62
±0,3
1
14
2,5
±0,3
15,24
±0,3
ø0,5
1
±0,2
4
±0,2
Pin
Pin
Pin
Pin
Pin
1
1
7
8
14
Voltage Control
N/C
GND
RF output
Supply Voltage (V
s
)
Ordering Code
Model
Example:
Order:
Notes
1
2
CA
CA
Code I
Frequency
Stability
15
Code II
Frequency
tuning
U
Code II U
Code III
RF
Output
06
±0,3
5,0
±1
4,5
18,8max.
7
8
Frequency
10M00000
Option “U” includes the mechanical frequ. control
can drive TTL, ACMOS and CMOS
Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage,
frequency control voltage, load, temperature (25°C)
Subject to technical modification; Not all options are available at all Frequencies
Corning Frequency Control • Worldwide Data Book 2001
v1.0.2000-11-02
Corning Frequency Control Inc.
• 100 Watts Street • Mt. Holly Springs, PA 17065 • Tel 1-717-486-3411 • Fax 1-717-486-5920 • www.corningfrequency.com
Tele Quarz GmbH & Co. KG
• Landstrasse • D-74924 Neckarbischofsheim, Germany • Tel +49-7268-801-0 • Fax +49-07268-801-281 • www.telequarz.de
2/2