首页 > 器件类别 > 连接器

EAG.2B.312.CLN

CONN RCPT FMALE 12POS GOLD SLDR

器件类别:连接器   

厂商名称:LEMO

厂商官网:http://www.lemo-china.com

器件标准:

下载文档
器件参数
参数名称
属性值
连接器类型
插座,母形插口
针脚数
12
外壳尺寸 - 插件
312
安装类型
面板安装,隔墙式;通孔
端接
焊接
紧固类型
推挽式,销锁
朝向
G
侵入防护
IP50 - 防尘
外壳材料,镀层
黄铜,镀铬
触头镀层
特性
屏蔽
额定电流
7A
触头镀层厚度
59.0µin(1.50µm)
工作温度
-55°C ~ 250°C
文档预览
unipole & multipole
connectors
No reproduction or use without express permission of editorial or pictorial content, in any manner.
LEMO reserve the right at all times to modify and improve specifications without any notification.
®
®
LEMO unipole and multipole connectors
This catalogue gives the complete description of LEMO unipole and multipole type connectors. The LEMO manufacturing
programme has been extended to almost 40 series divided into 7 product families with specific mating and environmental
characteristics. Each series includes a wide variety of plug, socket, coupler and bridge plug models, available in contact
configurations adapted to all round cables, including up to 114 conductors, and a maximum diameter of 30 mm.
Watertight and vacuumtight models are also available. Since LEMO connectors are perfectly screened and designed to
guarantee very low resistance to shell electrical continuity, they are particularly adapted to applications where electro-
magnetic compatibility (EMC) is important.
Table of Contents
3 steps to select the right connector
................................................................................................................................................................................ 3
B Series (indoor, keyed)
Part Numbering system ........................................................................................................................................................................................ 13
Metal Housing models ........................................................................................................................................................................................... 14
Elbow socket models ............................................................................................................................................................................................. 25
Plastic housing models .......................................................................................................................................................................................... 28
Watertight or vacuumtight models ......................................................................................................................................................................... 30
Bridge models ........................................................................................................................................................................................................ 34
Threaded-latching models ..................................................................................................................................................................................... 35
Alignment Key and Polarized Keying System........................................................................................................................................................ 36
K Series (outdoor, keyed)
Part Numbering system ......................................................................................................................................................................................... 38
Metal Housing models ........................................................................................................................................................................................... 39
Watertight or vacuumtight models ......................................................................................................................................................................... 47
Alignment Key and Polarized Keying System........................................................................................................................................................ 49
T Series (outdoor, keyed)
Part Numbering system ......................................................................................................................................................................................... 52
Metal Housing models ........................................................................................................................................................................................... 53
Watertight or vacuumtight models ......................................................................................................................................................................... 55
Plastic housing models, alignment Key and Polarized Keying System ................................................................................................................. 56
B, K and T Series
Insert configuration, Housings, Insulators, Contacts, Collets, Variant .................................................................................... 57
S Series (indoor, stepped insert)
Part Numbering system ........................................................................................................................................................................................ 75
Metal Housing models ........................................................................................................................................................................................... 76
Elbow socket models ............................................................................................................................................................................................. 87
Plastic housing models .......................................................................................................................................................................................... 89
Watertight or vacuumtight models ......................................................................................................................................................................... 91
E Series (outdoor, stepped insert)
Part Numbering system ......................................................................................................................................................................................... 94
Metal Housing models ........................................................................................................................................................................................... 95
Watertight or vacuumtight models ....................................................................................................................................................................... 101
S, and E Series
Insert configuration, Housings, Insulators, Contacts, Collets, Variant ...................................................................................... 103
M Series (outdoor, keyed)..............................................................................................................................................................................................
123
F Series (outdoor, keyed)
.............................................................................................................................................................................................. 125
Spare parts
...................................................................................................................................................................................................................... 127
Accessories
.................................................................................................................................................................................................................... 137
Tooling
............................................................................................................................................................................................................................. 151
Panel cut-outs and PCB drilling pattern
....................................................................................................................................................................... 157
Cable assembly
(B, K, T, S and E series)....................................................................................................................................................................... 169
Technical characteristics...............................................................................................................................................................................................
182
Product safety notice
..................................................................................................................................................................................................... 198
www.lemo.com
1
®
®
Precision modular connectors to suit your application
Over 75000 connectors
Since its creation in Switzerland in 1946 the LEMO Group has been recognized as a global leader of circular Push-Pull
connectors and connector solutions. Today LEMO and its affiliated companies, REDEL and COELVER, are active in
more than 80 countries with the help of over 40 subsidiaries and distributors.
The modular design of the LEMO range provides over 75000 connectors from miniature ø 3 mm to ø 50 mm, capable of
handling cable diameters up to 30 mm and for up to 114 contacts.
LEMO’s Push-Pull Self-Latching Connection System
This vast portfolio enables you to select the ideal connector configuration to suit almost any specific requirement in most
markets, including medical devices, test and measurement instruments, machinery, audio video broadcast, telecommuni-
cations and military.
This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute
security against vibration, shock or pull on the cable, and facilitates operation in a very limited space.
The LEMO self-latching system allows the connector
to be mated by simply pushing the plug axially into
the socket.
Once firmly latched, connection cannot be broken by
pulling on the cable or any other component part other
than the outer release sleeve.
When required, the connector is disengaged by a
single axial pull on the outer release sleeve.
This first disengages the latches and then withdraws
the plug from the socket.
LEMO connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (LEMO
connector, cable and your equipment) will be easier because LEMO connectors are recognized.
CE marking
means that the appliance or equipment bearing it complies with the protection requirements of one or
several European safety directives. CE marking
applies to complete products or equipment,
but not to electrome-
chanical components, such as connectors.
LEMO connector specifications conforms the requirements of the RoHS directive (2011/65/EU) of the European Parlia-
ment and the latest amendments. This directive specifies the restrictions of the use of hazardous substances in electrical
and electronic equipment marketed in Europe.
2
www.lemo.com
UL Recognition
CE marking
RoHS
®
®
l
Step 1: Select connector series
3 steps to select the right connector
Select the appropriate LEMO connector series according to the environmental parameters that will affect your device
or cable such as indoor, outdoor, temperature range, ingress protection of the mated connector and of your device.
Use the table shown on page 4.
Part number coding
.
l
Step 2: Select connector size
B, K, T, S or E
.
.
Use the section (mm
2
) or the AWG of your cable wire to select the optimal contact diameter (values vary between
solder, crimp or print contact), see page 8.
Use this optimal contact diameter to determine the right connector size as well as the insert configuration, see page 6.
Part number coding
.
l
Step 3: Complete the part number
0, 1, 2, 3, 4, 5 or 6
.
.
Now that you know the series, as well as the insulator configuration, complete the part numbering system with the help
of the following table.
Part number coding
.
.
.
B Series (indoor, keyed)
Model
39
76
14
Series
39
76
14
Insert
configuration
57
57
Housing
material
64
64
Insulator
material
64
64
Contact
64
64
Collet
68
67
Variant
71
71
T Series (outdoor, keyed)
K Series (outdoor, keyed)
S Series (indoor, stepped insert)
53
53
Note:
Figures in the above table refer to the catalogue pages.
E Series (outdoor, stepped insert)
95
95
103
103
57
112
112
64
112
112
64
112
112
64
119
115
70
121
121
71
www.lemo.com
3
查看更多>
请教版主STM32的抗干扰问题
我用STM32做了一个光源控制器,下面有个驱动板。用STM32引脚...
wenf stm32/stm8
yaffs2文件系统移植问题
首先说下环境吧,linux系统 内核2.6.24,flash 是一片 K9F4G08( 512M )...
zhangsf 嵌入式系统
HDL设计经验交流
1、不仅仅单纯的敲代码,注意代码描述的电路层次,在RTL级完成设计。 2、分析电路设计要求,寻求特点...
Leo417love FPGA/CPLD
如何实现电磁能的无线传输,请高手指教
实现 电磁能的无线传输 ,能够驱动红色发光二极管发光.发射源功率不得大于10W,传输距离不小于0.5...
wanli RF/无线
寻找IT界人才
  本公司是家上海的猎头公司,与上海众多IT公司有合作.希望全国各地的IT人才联系我们,我们希望通过...
lgspace 嵌入式系统
你们听说了吗?
你们听说了吗? 好样的,期待环境越来越好! 听说了。。。。。。。。。。。。。...
okhxyyo 电源技术
热门器件
热门资源推荐
器件捷径:
E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 EA EB EC ED EE EF EG EH EI EJ EK EL EM EN EO EP EQ ER ES ET EU EV EW EX EY EZ F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 FA FB FC FD FE FF FG FH FI FJ FK FL FM FN FO FP FQ FR FS FT FU FV FW FX FY FZ G0 G1 G2 G3 G4 G5 G6 G7 G8 G9 GA GB GC GD GE GF GG GH GI GJ GK GL GM GN GO GP GQ GR GS GT GU GV GW GX GZ H0 H1 H2 H3 H4 H5 H6 H7 H8 HA HB HC HD HE HF HG HH HI HJ HK HL HM HN HO HP HQ HR HS HT HU HV HW HX HY HZ I1 I2 I3 I4 I5 I6 I7 IA IB IC ID IE IF IG IH II IK IL IM IN IO IP IQ IR IS IT IU IV IW IX J0 J1 J2 J6 J7 JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ JR JS JT JV JW JX JZ K0 K1 K2 K3 K4 K5 K6 K7 K8 K9 KA KB KC KD KE KF KG KH KI KJ KK KL KM KN KO KP KQ KR KS KT KU KV KW KX KY KZ
需要登录后才可以下载。
登录取消