(All optical data refer to a coupled 9/125µm SM & 50/125µm MM fiber)
Optical and Electrical Characteristics 1300nm (Tc=25ºC)
Parameter
Wavelength
Spectral Width
Operating Current
Output Power (SM, 9/125µm)
L
M
H
U
Output Power (MM, 50/125µm)
M
H
U
Spectral Ripple
Foward Voltage
Rise Time
Fall Time
Output Power Variation
Symbol
λ
∆λ
I
op
P
O
Min
1260
30
-
10
50
100
150
50
100
200
-
-
-
Typ
1300
-
80
-
-
-
-
-
-
-
-
1.2
1.5
2.5
4
Max
1340
70
-
-
-
-
-
-
-
-
10
2.0
-
-
-
Unit
nm
nm
mA
Test Conditions
CW
CW(FWHM)
CW
µW
CW at Iop=80mA
P
O
µW
%
V
ns
ns
dB
CW at Iop=80mA
λ±10nm
CW
Vf
T
r
T
f
-
-
25ºC to 70ºC
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMNDS703-DEC2805
rev. A.7
1
ELED FC Receptacle
EDR-L-XXB-X-XFCX-XX
(All optical data refer to a coupled 9/125µm SM & 50/125µm MM fiber)
Optical and Electrical Characteristics 1550nm (Tc=25ºC)
Parameter
Wavelength
Spectral Width
Operating Current
Output Power (SM, 9/125µm)
L
M
H
Output Power (MM, 50/125µm)
L
M
H
Spectral Ripple
Foward Voltage
Rise Time
Fall Time
Output Power Variation
Symbol
λ
∆λ
I
op
P
O
Min
1510
45
-
10
20
30
30
50
70
-
-
-
Typ
1550
-
80
-
-
-
-
-
-
-
1.2
1.5
2.5
4
Max
1580
100
100
-
-
-
-
-
-
10
2.0
-
-
-
Unit
nm
nm
mA
µW
Test Conditions
CW
CW(FWHM)
CW
CW at Iop=80mA
P
O
µW
CW at Iop=80mA
λ±10nm
CW
%
V
ns
ns
dB
Vf
T
r
T
f
-
-
25ºC to 70ºC
Ordering Information
Family
EDR=ELED Receptacle
Wavelength
30:1300nm
50:1550nm
Power
L/M/H/U
Connector
Option
FC = FC
E=FC
G=FC-SF
L=FC-BL
F=FC-L
L=Long
Device
Tolerance
B=+/- 40nm
S=9/125µm
M=50/125µm
Fiber
RoHS Compliant
-/G5/GR
Blank = RoHS non-compliant product
G5 = RoHS 5/6-compliant product (lead exemption)
GR = Full RoHS compliant product (no exemption)
LUMNDS703-DEC2805
rev. A.7
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
2
ELED FC Receptacle
EDR-L-XXB-X-XFCX-XX
Pin Assignment
Mechanical Drawing
Mechanical Drawing
2
1
Units in mm.
3
Dril Thru and Tapped 2-56
(2 Places)
2-#2-56 THROUGH
LUMINENTOIC.COM
20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486
9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213
LUMNDS703-DEC2805
rev. A.7
3
ELED FC Receptacle
EDR-L-XXB-X-XFCX-XX
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended.
Follow guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
Legal Notice
IMPORTANT NOTICE!
All information contained in this document is subject to change without notice, at Luminent’s sole and absolute discretion. Luminent warrants perfor-
mance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as
“preliminary” are given to describe components only, and Luminent expressly disclaims any and all warranties for said products, including express, implied,
and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the
company’s Terms and Conditions of Sale for further warranty information.
Luminent assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intel-
lectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and
Luminent makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights.
Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or
death to persons. Luminent customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify
Luminent for any damages resulting from such use or sale.
THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that Luminent is not liable for any actual, con-
sequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact
Luminent to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current.