HLMP-ELxx, HLMP-EHxx, HLMP-EJxx, HLMP-EGxx
T-1
3
/
4
(5 mm) Precision Optical Performance
AlInGaP LED Lamps
Data Sheet
Description
These Precision Optical Performance AlInGaP LEDs provide
superior light output for excellent readability in sunlight
and are extremely reliable. AlInGaP LED technology pro-
vides extremely stable light output over long periods of
time. Precision Optical Performance lamps utilize the alumi-
num indium gallium phosphide (AlInGaP) technology.
These LED lamps are untinted, nondiffused, T-1
3
/
4
pack-
ages incorporating second generation optics producing
well defined spatial radiation patterns at specific viewing
cone angles.
These lamps are made with an advanced optical grade
epoxy, offering superior high temperature and high mois-
ture resistance performance in outdoor signal and sign
applications. The high maximum LED junction tempera-
ture limit of +130°C enables high temperature operation
in bright sunlight conditions. The package epoxy contains
both uv-a and uv-b inhibitors to reduce the effects of long
term exposure to direct sunlight.
These lamps are available in two package options to give
the designer flexibility with device mounting.
Features
•
Well defined spatial radiation patterns
•
Viewing angles: 8°, 15°, 23°, 30°
•
High luminous output
•
Colors:
590 nm amber
605 nm orange
615 nm reddish-orange
626 nm red
•
High operating temperature: T
J
led
= +130°C
•
Superior resistance to moisture
•
Package options:
With or without lead stand-offs
Applications
•
Traffic management:
Traffic signals
Pedestrian signals
Work zone warning lights
Variable message signs
•
Commercial outdoor advertising:
Signs
Marquees
•
Automotive:
Exterior and interior lights
Benefits
•
Viewing angles match traffic management sign require-
ments
•
Colors meet automotive and pedestrian signal speci-
fications
•
Superior performance in outdoor environments
•
Suitable for autoinsertion onto PC boards
Device Selection Guide
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
8°
Color and Dominant
Wavelength
(nm), Typ.
[3]
Amber 590
Lamps without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL08-T0000
HLMP-EL08-VY000
HLMP-EL08-VYK00
HLMP-EL08-WZ000
HLMP-EL08-X1K00
HLMP-EL08-X1000
Orange 605
HLMP-EJ08-WZ000
HLMP-EJ08-X1000
HLMP-EJ08-Y2000
Red-Orange 615
HLMP-EH08-UX000
HLMP-EH08-WZ000
HLMP-EH08-X1000
HLMP-EH08-Y2000
Red 626
HLMP-EG08-T0000
HLMP-EG08-VY000
HLMP-EG08-WZ000
HLMP-EG08-X1000
HLMP-EG08-YZ000
HLMP-EG08-Y2000
HLMP-EG10-Y2000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each intensity bin limit is ± 15%.
Lamps with Standoffs
on Leads
(Outline Drawing B)
HLMP-EL10-T0000
HLMP-EL10-VY000
HLMP-EL10-WZ000
HLMP-EL10-X1K00
HLMP-EL10-X1000
HLMP-EJ10-X1000
HLMP-EH10-UX000
HLMP-EH10-WZ000
HLMP-EH10-X1000
HLMP-EH10-Y2000
HLMP-EG10-T0000
HLMP-EG10-WZ000
HLMP-EG10-X1000
Luminous Intensity
Iv (mcd)
[1,2,5]
@ 20 mA
Min.
Max.
2500
4200
4200
5500
7200
7200
5500
7200
9300
3200
5500
7200
9300
2500
4200
5500
7200
9300
9300
–
12000
12000
16000
21000
21000
16000
21000
27000
9300
16000
21000
27000
–
12000
16000
21000
16000
27000
2
Device Selection Guide
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
15°
Color and Dominant
Wavelength
(nm), Typ.
[3]
Amber 590
HLMP-EL15-PS000
HLMP-EL15-QSK00
HLMP-EL15-QT000
HLMP-EL15-RU000
HLMP-EL15-TW000
HLMP-EL15-TWK00
HLMP-EL15-UX000
HLMP-EL15-VY000
HLMP-EL15-VYK00
HLMP-EL15-VW000
Orange 605
HLMP-EJ15-PS000
HLMP-EJ15-RU000
HLMP-EJ15-SV000
Red-Orange 615
HLMP-EH15-QT000
HLMP-EH15-RU000
HLMP-EH15-TW000
HLMP-EH15-UX000
Red 626
HLMP-EG15-N0000
HLMP-EG15-PS000
HLMP-EG15-QT000
HLMP-EG15-RU000
HLMP-EG15-UX000
HLMP-EG15-TW000
HLMP-EG17-QT000
HLMP-EG17-RU000
HLMP-EG17-UX000
HLMP-EG17-TW000
HLMP-EH17-TW000
HLMP-EH17-UX000
HLMP-EG17-N0000
HLMP-EJ17-SV000
HLMP-EJ17-QT000
HLMP-EL17-UX000
HLMP-EL17-VY000
HLMP-EL17-TW000
Lamps without
Standoffs on Leads
(Outline Drawing A)
Lamps with Standoffs
on Leads
(Outline Drawing B)
HLMP-EL17-M0000
Luminous Intensity
Iv (mcd)
[1,2,5]
@ 20 mA
Min.
Max.
520
880
1150
1150
1500
2500
2500
3200
4200
4200
4200
1150
880
1500
1900
1150
1500
2500
3200
680
880
1150
1500
3200
2500
–
2500
2500
3200
4200
7200
7200
9300
12000
12000
7200
3200
2500
4200
5500
3200
4200
7200
9300
–
2500
3200
4200
9300
7200
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each intensity bin limit is ± 15%.
3
Device Selection Guide
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
23°
Color and Dominant
Wavelength
(nm), Typ.
[3]
Amber 590
Lamps without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL24-L0000
HLMP-EL24-MQ000
HLMP-EL24-NR000
HLMP-EL24-PS000
HLMP-EL24-QR000
HLMP-EL24-QRK00
HLMP-EL24-QS400
HLMP-EL24-QT000
HLMP-EL24-RU000
HLMP-EL24-RUK00
HLMP-EL24-SV000
HLMP-EL24-SUK00
HLMP-EL24-SU400
HLMP-EL24-SVK00
HLMP-EL24-TW000
HLMP-EL24-TWK00
Orange 605
Red-Orange 615
HLMP-EJ24-QT000
HLMP-EH24-PS000
HLMP-EH24-QT000
HLMP-EH24-RU000
HLMP-EH24-SV000
Red 626
HLMP-EG24-M0000
HLMP-EG24-PS000
HLMP-EG24-QT000
HLMP-EG24-RU000
HLMP-EG26-RU000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each intensity bin limit is ± 15%.
Lamps with Standoffs
on Leads
(Outline Drawing B)
HLMP-EL26-L0000
Luminous Intensity
Iv (mcd)
[1,2,5]
@ 20 mA
Min.
Max.
400
520
680
–
1500
1900
2500
1900
1900
2500
3200
4200
4200
5500
4200
4200
5500
7200
7200
3200
2500
3200
4200
5500
–
2500
4200
4200
HLMP-EL26-PS000
880
1150
1150
1150
HLMP-EL26-QT000
HLMP-EL26-RU000
HLMP-EL26-SV000
1150
1150
1150
1900
1900
1900
1900
HLMP-EL26-TW000
2500
2500
1150
HLMP-EH26-PS000
880
1150
1500
HLMP-EH26-SV000
HLMP-EG26-M0000
HLMP-EG26-PS000
1900
520
880
1150
1500
4
Device Selection Guide
Typical
Viewing Angle
2θ
1
/
2
(Deg.)
[4]
30°
Color and Dominant
Wavelength
(nm), Typ.
[3]
Amber 590
Lamps without
Standoffs on Leads
(Outline Drawing A)
HLMP-EL30-K0000
HLMP-EL30-MQ000
HLMP-EL32-NR000
HLMP-EL30-PQ000
HLMP-EL30-PR400
HLMP-EL30-PS000
HLMP-EL30-PSK00
HLMP-EL30-QT000
HLMP-EL30-QTK00
HLMP-EL30-ST000
HLMP-EL30-SU400
HLMP-EL30-SUK00
HLMP-EL30-STK00
HLMP-EL30-SV000
HLMP-EL30-SVK00
Orange 605
Red-Orange 615
HLMP-EJ30-NR000
HLMP-EJ30-PS000
HLMP-EH30-MQ000
HLMP-EH30-NR000
HLMP-EH30-PS000
HLMP-EH30-QT000
HLMP-EH30-RU000
Red 626
HLMP-EG30-K0000
HLMP-EG30-KN000
HLMP-EG30-MQ000
HLMP-EG30-NQ000
HLMP-EG30-NR000
HLMP-EG30-PQ000
HLMP-EG30-PR000
HLMP-EG30-PS000
HLMP-EG30-QT000
HLMP-EG32-QT000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2. The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
λ
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
θ
1/2
is the off-axis angle where the luminous intensity is half the on-axis intensity.
5. Tolerance for each intensity bin limit is ± 15%.
Lamps with Standoffs
on Leads
(Outline Drawing B)
HLMP-EL32-K0000
Luminous Intensity
Iv (mcd)
[1,2,5]
@ 20 mA
Min.
Max.
310
520
680
880
880
–
1500
1900
1500
1900
2500
2500
3200
3200
3200
4200
4200
3200
5500
5500
1900
2500
1500
1900
2500
4200
4200
–
880
1500
1500
1900
1500
1900
2500
3200
HLMP-EL32-PS000
HLMP-EL32-QT000
880
880
1150
1150
1900
1900
1900
1900
HLMP-EL32-SV000
1900
1900
680
HLMP-EJ32-PS000
HLMP-EH32-MQ000
HLMP-EH32-NR000
HLMP-EH32-PS000
HLMP-EH32-QT000
HLMP-EH32-RU000
HLMP-EG32-K0000
HLMP-EG32-MQ000
HLMP-EG32-NR000
880
520
680
880
1150
1500
270
310
520
680
680
880
880
880
1150
5