器件参数
参数名称
属性值
产品种类
Product Category
Switching Power Supplies
制造商
Manufacturer
Cosel
RoHS
Details
产品
Product
Switching Supplies
Output Voltage-Channel 1
3.3 V
Number of Outputs
1 Output
Output Power
99 W
Open Frame/Enclosed
Open Frame
Input Voltage
85 VAC to 264 VAC
Output Current-Channel 1
30 A
Commercial/Medical
Commercial
Isolation Voltage
3 kV
安装风格
Mounting Style
Chassis
长度
Length
160 mm
宽度
Width
75 mm
高度
Height
33.5 mm
Input Frequency
50 Hz/60 Hz
Load Regulation
Regulated
Power - Convection
99 W
工厂包装数量
Factory Pack Quantity
30
单位重量
Unit Weight
13.756845 oz
文档预览
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LFA10F
LF
1
2
A
3
10
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-04-472
LFA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C : with Coating
G : Low leakage current
J1 : VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y : with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA10F-3R3-Y
6.6
3.3V 2A
LFA10F-5
10
5V 2A
LFA10F-12
10.8
12V 0.9A
LFA10F-15
10.5
15V 0.7A
LFA10F-24
12
24V 0.5A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
LFA10F-3R3-Y
LFA10F-5
LFA10F-12
LFA10F-15
LFA10F-24
*3
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
0.18typ (Io=100%)
0.26typ (Io=100%)
0.11typ (Io=100%)
0.16typ (Io=100%)
50 / 60 (47 - 440)
68.0typ
74.0typ
76.5typ
77.5typ
79.5typ
68.5typ
76.0typ
79.0typ
80.0typ
83.0typ
15typ (Io=100%)
30typ (Io=100%)
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
2.0
2.0
0.9
0.7
0.5
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
190max
160max
240max
240max
280max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
240max
240max
300max
300max
320max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)
*Start-up
time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Class A)
*6
(Not built-in to active filter)
*4
50X22X73.5mm [1.97X0.87X2.89 inches] (WXHXD) / 55g max (with chassis & cover : 150g max)
Convection (Refer to Instruction Manual 3.1 and 3.2)
*3
factor Io=0-35% is different.
Please refer to the Instruction Manual 1.7.
Drift is the change in DC output for an eight hour period after
a half-hour warm-up at 25C, with the input voltage held
constant at the rated input/output.
Derating is required.
When two or more units are operating it may not comply with
the IEC61000-3-2.
*5
*6
*
*
*
*
Please contact us for details.
Please contact us about dynamic load and input response.
Please contact us about another class.
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse
load.
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*5
LINE REGULATION[mV]
LOAD REGULATION[mV]
*5
0 to +50C
RIPPLE[mVp-p]
-10 - 0C
*1
Io=0 - 35%
0 to +50C
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0C
*1
Io=0 - 35%
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
ISOLATION
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
EFFICIENCY[%]
*1
This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
A circuit reducing standby power is built in this unit.
Therefore, the internal switch element is intermittent
operated, and the Ripple/Ripple Noise specification in load
*2
*3
*4
LFA-2
LFA10F
Block diagram
FUSE
AC250V
2A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
AC IN
85 264V
NOISE
FILTER
LFA
FG
TRANSFORMER
CONTROL
INVERTER
RECTIFIER
AND
FILTER
DC OUT
CURRENT
SENSING
Photocoupler
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
External view
[0.2]
5
FG
Standard type
4.6
[0.18]
Chassis and cover type
f3.5
[1.25]
83.5
±
0.5
[3.29]
5
[0.2]
4-M3
Mounting Hole
[1.97]
40
±
0.5
[1.57]
CN1
5
3
1
Input(L)
5
[0.2]
63.5
±
0.5
[2.5]
Input(L)
1
Name plate
73.5
[2.89]
Point A
Point B
[0.71]
93.5
[3.68]
18
f3.5
83.5
±
0.5
[3.29]
5
[0.2]
4max
[0.16]
¶1
¶1
Surface mount device
[0.14]
3.5
[0.43]
11
PCB t=1.6
[0.14]
3.5
Voltage adjust
(LFA10F-3R3-Y or optional)
2-f3.5
Mounting Hole
30
±
0.5
[1.18]
Input(N)
3
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
I/O Connector
CN1
1-1123724-3
CN2
1-1123723-2
Mating connector
Terminal
1123721-1
Chain
Loose
1318912-1
Chain
1123721-1
Loose
1318912-1
(Mfr:Tyco
Electronics)
2-M3
Mounting Hole
<PIN CONNECTION>
CN1
Pin No.
1
2
3
4
5
Input
AC(L)
AC(N)
FG
CN2
Pin No.
1
2
Output
-V
+V
Tolerance :
±1
[±0.04]
Weight : 55g max (with chassis & cover : 150g max)
PCB material / thickness : CEM3 / 1.6mm
Optional chassis and cover material : Electric galvanizing steel board.
Dimensions in mm, [ ]=inches
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
1-1123722-5
1-1123722-2
I/O Connector is Mfr. Tyco Electronics
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
[0.63]
16
[1.26]
32
LFA-3
[2.36]
FG
CN1
5
CN2
1
2
Output(-)
Output(+)
[1.18]
Input(N)
[0.59]
50
15
FG
1
2
Output(-)
Output(+)
31.7
CN2
30
60
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LFA15F
LF
1
2
A
3
15
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-04-472
LFA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C : with Coating
G : Low leakage current
J1 : VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y : with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA15F-3R3-Y
9.9
3.3V 3A
LFA15F-5
15
5V 3A
LFA15F-12
15.6
12V 1.3A
LFA15F-15
15
15V 1A
LFA15F-24
16.8
24V 0.7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
*5
LINE REGULATION[mV]
LOAD REGULATION[mV]
*5
0 to +50C
RIPPLE[mVp-p]
-10 - 0C
*1
Io=0 - 35%
0 to +50C
RIPPLE NOISE[mVp-p]
OUTPUT
-10 - 0C
*1
Io=0 - 35%
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
PROTECTION OVERVOLTAGE PROTECTION
CIRCUIT AND OPERATING INDICATION
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
ISOLATION
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
ENVIRONMENT
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND
NOISE
CONDUCTED NOISE
REGULATIONS HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
OTHERS
COOLING METHOD
EFFICIENCY[%]
*1
ACIN 100V
ACIN 200V
INPUT
LFA15F-3R3-Y
LFA15F-5
LFA15F-12
LFA15F-15
LFA15F-24
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
*3
0.24typ (Io=100%)
0.35typ (Io=100%)
0.15typ (Io=100%)
0.20typ (Io=100%)
50 / 60 (47 - 440)
68.0typ
73.0typ
76.0typ
77.0typ
78.0typ
69.0typ
76.0typ
78.5typ
80.0typ
81.5typ
15typ (Io=100%) (At cold start) (Ta=25C)
30typ (Io=100%) (At cold start) (Ta=25C)
0.15/0.30max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
3.0
3.0
1.3
1.0
0.7
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
190max
160max
240max
240max
280max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
240max
240max
300max
300max
320max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
200typ (ACIN 100V, Io=100%)
*Start-up
time is 700ms typ for less than 1minute of applying input again from turning off the input voltage.
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000 feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Class A)
*6
(Not built-in to active filter)
*4
50X22X87.5mm [1.97X0.87X3.44 inches] (WXHXD) / 80g max (with chassis & cover : 190g max)
Convection (Refer to Instruction Manual 3.1 and 3.2)
*3
factor Io=0-35% is different.
Please refer to the Instruction Manual 1.7.
Drift is the change in DC output for an eight hour period after
a half-hour warm-up at 25C, with the input voltage held
constant at the rated input/output.
Derating is required.
When two or more units are operating it may not comply with
the IEC61000-3-2.
*5
*6
*
*
*
*
Please contact us for details.
Please contact us about dynamic load and input response.
Please contact us about another class.
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse
load.
This is the value that measured on measuring board with
capacitor of 22mF at 150mm from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter
(Equivalent to KEISOKU-GIKEN: RM103).
A circuit reducing standby power is built in this unit.
Therefore, the internal switch element is intermittent
operated, and the Ripple/Ripple Noise specification in load
*2
*3
*4
LFA-4
LFA15F
Block diagram
FUSE
AC250V
2.5A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
AC IN
85 264V
NOISE
FILTER
LFA
FG
TRANSFORMER
CONTROL
INVERTER
RECTIFIER
AND
FILTER
DC OUT
CURRENT
SENSING
Photocoupler
CONTROL
Photocoupler
OVER VOLTAGE
PROTECTION
External view
Standard type
[0.2]
Chassis and cover type
4.4
[0.17]
FG
f3.5
97.5
±
0.5
[3.84]
5
[0.2]
4-M3
Mounting Hole
5
[1.97]
40
±
0.5
[1.57]
5
3
1
FG
Input(N)
Input(L)
30
±
0.5
[1.18]
5
[0.2]
77.5
±
0.5
[3.05]
2-f3.5
Mounting Hole
Input(L)
1
Name plate
87.5
[3.44]
Point A
Point B
f3.5
107.5
[4.23]
97.5
±
0.5
[3.84]
5
[0.2]
[0.71]
18
[0.14]
[0.43]
3.5
11
[0.14]
3.5
Input(N)
3
4max
[0.16]
¶1
Surface mount device
2-M3
Mounting Hole
The back side of P.C.B. of the power supply is assembled some
SMDs.
Be attention not to bump against the attached area by vibration.
Use the spacer of 8mm length or more regarding insulation.
And do not use press-fitting bush.
Point A, Point B are thermometry points. Please refer to
Instruction Manual 3.
I/O Connector
CN1
1-1123724-3
CN2
1-1123723-2
Mating connector
Terminal
1123721-1
Chain
Loose
1318912-1
Chain
1123721-1
Loose
1318912-1
(Mfr:Tyco
Electronics)
<PIN CONNECTION>
CN1
Pin No.
1
2
3
4
5
Input
AC(L)
AC(N)
FG
CN2
Pin No.
1
2
Output
-V
+V
Tolerance :
±1
[±0.04]
Weight : 80g max (with chassis & cover : 190g max)
PCB material / thickness : CEM3 / 1.6mm
Optional chassis and cover material : Electric galvanizing steel board.
Dimensions in mm, [ ]=inches
Mounting torque (Mounting hole of chassis) : 0.6N
-
m (6.3kgf
-
cm) max
1-1123722-5
1-1123722-2
I/O Connector is Mfr. Tyco Electronics
Option:-J1:(J.S.T) connector type. Refer to Instruction Manual 5.
16
PCB t=1.6
[0.63]
¶1
LFA-5
[1.26]
32
[2.36]
60
Voltage adjust
(LFA15F-3R3-Y or optional)
CN1
CN2
1
2
FG
5
Output(-)
Output(+)
[1.18]
50
30
1
2
[0.59]
CN1
CN2
Output(-)
Output(+)
[1.17]
29.7
15
AC-DC Power Supplies Open Frame/ Enclosed Type
Ordering information
LFA30F
LF
1
2
A
3
30
4
F
5
-O
6
-O
R
Recommended EMI/EMC Filter
NAC-04-472
LFA
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
The EMI/EMC Filter is recommended
to connect with several devices.
1
Series name
2
Single output
3
Output wattage
4
Universal input
5
Output voltage
6
Optional
C : with Coating
G : Low leakage current
J1 : VH(J.S.T.)connector type
S : with Chassis
SN: with Chassis & cover
Y : with Potentiometer
Specification is changed at
option, refer to Instruction
Manual.
This power supply is manufactured by SMD technology. The stress to P.C.B like twisting or bending causes the defect of the unit, so handle the unit with care.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
LFA30F-3R3-Y
19.8
3.3V 6A
LFA30F-5
30.0
5V 6A
LFA30F-12
30.0
12V 2.5A
LFA30F-15
30.0
15V 2A
LFA30F-24
31.2
24V 1.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
INPUT
ACIN 100V
ACIN 200V
ACIN 100V
INRUSH CURRENT[A]
ACIN 200V
LEAKAGE CURRENT[mA]
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
*5
LOAD REGULATION[mV]
*5
0 to +50C
*1
RIPPLE[mVp-p]
-10 - 0C
*1
0 to +50C
*1
RIPPLE NOISE[mVp-p]
-10 - 0C
*1
0 to +50C
TEMPERATURE REGULATION[mV]
-10 to +50C
*2
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
OVERVOLTAGE PROTECTION
OPERATING INDICATION
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
OUTPUT-FG
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
CASE SIZE/WEIGHT
COOLING METHOD
EFFICIENCY[%]
ACIN 100V
ACIN 200V
LFA30F-3R3-Y
LFA30F-5
LFA30F-12
LFA30F-15
LFA30F-24
AC85 - 264 1f (Refer to Instruction Manual 1.1 and 3.2)
*3
0.50typ (Io=100%)
0.65typ (Io=100%)
0.30typ (Io=100%)
0.35typ (Io=100%)
50 / 60 (47 - 440)
73typ
76typ
79typ
81typ
82typ
75typ
79typ
81typ
83typ
84typ
15typ (Io=100%)
(At cold start)
(Ta=25C)
30typ (Io=100%)
(At cold start)
(Ta=25C)
0.30 / 0.65max (ACIN 100V / 240V 60Hz, Io=100%, According to IEC60950-1 and DEN-AN)
3.3
5
12
15
24
6.0
6.0
2.5
2.0
1.3
20max
20max
48max
60max
96max
40max
40max
100max
120max
150max
80max
80max
120max
120max
120max
140max
140max
160max
160max
160max
120max
120max
150max
150max
150max
160max
160max
180max
180max
180max
50max
50max
120max
150max
240max
60max
60max
150max
180max
290max
20max
20max
48max
60max
96max
150typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
2.85 to 3.63
Fixed (“Y”option is available for adjusting output voltage between
±10%)
3.30 to 3.40
4.90 to 5.30
11.50 to 12.50
14.40 to 15.60
23.00 to 25.00
Works over 105% of rating and recovers automatically
4.00 to 5.25
5.75 to 7.00
13.80 to 16.80
17.25 to 21.00
27.60 to 33.60
Not provided
Not provided
Not provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At Room Temperature)
AC500V 1minute, Cutoff current = 25mA, DC500V 50MW min (At Room Temperature)
-10 to +70C, 20 - 90%RH (Non condensing) (Refer to Instruction Manual 3.2), 3,000m (10,000feet) max
*3
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL (CSA60950-1), EN60950-1, EN60065, EN50178 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 (Class A)
*6
(Not built-in to active filter)
*4
50X26.5X105mm [1.97X1.04X4.13 inches] (WXHXD) / 130g max (with chassis & cover : 260g max)
Convection (Refer to Instruction Manual 3.1 and 3.2)
*3
*4
*5
*6
*
*
*
*
When two or more units are operating it may not comply with the IEC61000-3-2.
Please contact us for details.
Please contact us about dynamic load and input response.
Please contact us about another class.
To meet the specifications. Do not operate over-loaded condition.
Parallel operation is not possible.
Derating is required when operated with chassis and cover.
Sound noise may be generated by power supply in case of pulse load.
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
*1
*2
*3
This is the value that measured on measuring board with capacitor of 22mF at 150mm
from output terminal.
Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to KEISOKU-GIKEN:
RM103).
Drift is the change in DC output for an eight hour period after a half-hour warm-up at
25C, with the input voltage held constant at the rated input/output.
Derating is required.
LFA-6
查看更多>
语音通话系统在核磁共振设备中的运用
现目前找不到研究背景和意义啊~有哪位大大能帮帮忙么~~感激不尽啊 语音通话系统在核磁共振设备中的运...
echo12280809 医疗电子
150M的虚拟示波器 DSO-2150 USB
DSO-2150 USB ...
hantek123 测试/测量
PIC32MX250 休眠后电平中断唤醒不成功
MCU: PIC32MX250F128D A1 问题:怎么样才能成功电平变化唤醒MCU? 调试程序...
viphotman Microchip MCU
UWB 的成本是多少
近年来,超宽带套件的价格开始迅速下降。它们不仅在企业环境(工厂自动化、资产跟踪)中而且在更广泛的消...
兰博 RF/无线
初学ucos,请大神指教~~~
小弟初学ucos,如下这段程序是任哲《嵌入式操作系统ucos原理及应用》当中的例子,是在BC3.1中...
liuchang--- 实时操作系统RTOS
[X-NUCLEO-53L4A3 TOF评估板]1.测试和代码移植
首先感谢EEWORLD以及得捷电子给予这次测评的机会。 先了解一下VL53L4ED官方参数特性...
镜花水月000 传感器
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消