ture compensation: -25...70 °C - conforming to IEC
60947-6-2
Class 10 - frequency limit: 40...60 Hz - temperature
compensation: -25...70 °C - conforming to UL 508
Utilisation category
Motor power kW
Thermal protection ad-
justment range
[Uc] control circuit volt-
age
Overload tripping class
Complementary
Main function available
Earth fault protection
Manual reset
Protection against overload and short-circuit
Protection against phase failure and phase imbalance
Plug-in
Front side
20...26.5 V for AC circuit 24 V in operation
140 mA at 24 V AC I maximum while closing with LUB12
220 mA at 24 V AC I maximum while closing with LUB32
70 mA at 24 V AC I rms sealed with LUB12
90 mA at 24 V AC I rms sealed with LUB32
35 ms opening with LUB12 for control circuit
35 ms opening with LUB32 for control circuit
70 ms closing with LUB12 for control circuit
70 ms closing with LUB32 for control circuit
3-phase motor - cooling: self-cooled
14.2 x Ir +/- 20 %
600 V conforming to CSA 22-2 No 14
600 V conforming to UL 508
690 V conforming to IEC 60947-1
Mounting mode
Mounting location
Control circuit voltage limits
Typical current consumption
Operating time
Load type
Tripping threshold
[Ui] rated insulation voltage
Jan 5, 2018
1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
[Uimp] rated impulse withstand voltage
Safe separation of circuit
6 kV conforming to IEC 60947-6-2
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1
400 V SELV between the control or auxiliary circuit and the main circuit conform-
ing to IEC 60947-1
0.140 kg
Product weight
Environment
Heat dissipation
Immunity to microbreaks
Immunity to voltage dips
Standards
2 W for control circuit with LUB12
3 W for control circuit with LUB32
3 ms
70 % 500 ms conforming to IEC 61000-4-11
CSA C22-2 No 14 type E
EN 60947-6-2
IEC 60947-6-2
UL 508 type E with phase barrier
ABS
ASEFA
ATEX
BV
CCC
CSA
DNV (Det Norske Veritas)
GL
GOST
LROS (Lloyds register of shipping)
UL
IP20 front panel and wired terminals conforming to IEC 60947-1
IP20 other faces conforming to IEC 60947-1
IP40 front panel outside connection zone conforming to IEC 60947-1
TH conforming to IEC 60068
-25...60 °C with LUCM
-25...70 °C with LUCA, LUCB, LUCC, LUCD
-40...85 °C
2000 m
650 °C conforming to IEC 60695-2-12
960 °C parts supporting live components conforming to IEC 60695-2-12
10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
2 gn 5...300 Hz power poles open conforming to IEC 60068-2-6
4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6
8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
1 kV serial mode conforming to IEC 60947-6-2
2 kV common mode conforming to IEC 60947-6-2
10 V/m 3 conforming to IEC 61000-4-3
2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4