首页 > 器件类别 > 电源/电源管理

OL20K/144PR

Switching Power Supplies PWR SPLY:20kW Stack System, +O/P, ACE

器件类别:电源/电源管理   

厂商名称:Advanced Energy

器件标准:

下载文档
器件参数
参数名称
属性值
Product Attribute
Attribute Value
制造商
Manufacturer
Advanced Energy
产品种类
Product Category
Switching Power Supplies
RoHS
Details
文档预览
20kW HIGH VOLTAGE POWER SUPPLY
Series OL20K
FEATURES
20kW of output power
Output voltages from 60kV to over 200kV
Positive or Negative polarity to order
Robust IGBT converter design
Exceptional reliability
High Stability
Excellent inherent ruggedness
Arc Count and Extinguish (ACE) option
Marked
DESCRIPTION
The Series OL20K is a range of high reliability products designed to
meet the rigorous requirements of ion and electron beam systems.
These high performance switch mode systems are based on a power
converter using zero-volt switching. A full bridge of the latest
generation of Insulated Gate Bipolar Transistors (IGBTs) in a fully
regulated closed-loop system capable of continuously supplying up
to 20kW of output power whilst maintaining flexible control down to
a few hundred Watts. These highly reliable rugged systems comprise
two units, a rack mounting power converter through which remote
controls are facilitated, and a separate HV unit employing a modular
disc construction. Numerous features are incorporated to ensure
system integrity is maintained during adverse operating conditions.
Such features include continuous primary current monitoring with
fast pulse truncation and soft recovery, extensive thermal monitoring
and automatic shutdown on key components, passive output current
limiting for instantaneous surge control and independent output
overvoltage sensing. Optionally HiTek Power’s Arc Count and
Extinguish (ACE) system can be installed for active arc management.
Input Voltage:
208VAC ±10% (187VAC to 229VAC) 47-63Hz 3 phase via three M8 studs,
and earth, via M10 stud at 87A rms per phase.
OR
400VAC ±10% (360VAC to 440VAC) 47-63Hz 3 phase via three M6 studs,
and earth, via M8 stud 45A rms per phase.
Polarity:
Positive or negative to order.
Minimum Voltage:
5% of rated output voltage. The unit may be turned down below this but
the specifications are not guaranteed below this level.
Line Regulation:
Less than 0.1% change in output voltage for a 10% change in mains
voltage.
Load Regulation:
Less than 0.1% of rated output voltage for a full load change.
Ripple:
Less than 0.1% peak to peak of rated output voltage.
Transient Response:
The output will recover to within ±1% of set value in less than 100ms
from the removal of a short circuit.
Temperature Coefficient:
200ppm/oC (0.02%/oC).
SPECIFICATION
Output Power:
20kW maximum at full rated output voltage and current.
Output Voltage:
Units available with maximum output voltages from 60kV to 200kV.
Output Current:
Up to 250mA for 60kV and 80mA for 200kV.
w w w. h i t e k p o w e r. c o m
Series OL20K
20kW HIGH VOLTAGE POWER SUPPLY
Drift:
Less than 0.5%/8 hours after 1 hour warm up.
Front Panel Controls and Indicators:
Circuit Breaker HV On indicator
HV Off indicator
Trip indicator
Operating Temperature:
0°C to +40°C (32°F to 140°F) ambient and air intake.
Storage Temperature:
-20°C to +85°C (-4°F to 185°F).
Humidity:
80% maximum relative humidity up to 31°C, reducing linearly to 50% at
40°C. Non-condensing (ref BS EN61010-1).
Vibration:
In accordance with BS EN60068-2-6: 1995
Transport, when contained in the original packaging.
Frequency range: 10Hz to 500Hz
Acceleration:
20m/s
2
crossover at 58Hz (table C.2)
Displacement:
0.15mm maximum
Test conditions as defined in table A.1.
Altitude:
Sea level to 2000 metres (6500 feet).
Installation Category:
II (BS EN61010-1)
Pollution Degree:
2 (BS EN61010-1)
Usage:
Indoor use only.
Control:
The power supply is operated by remote control via the 25-way D-type
connector situated on the rear panel of the converter. Full control and
monitoring functions are available by this method. Application of 0 to
10V to the voltage and current control lines programmes the unit for 0 to
100% of rated output. Similarly 0 to 10V signals provide monitors of the
output voltage and current levels. HV ON/OFF is obtained by shorting
two teminals and status lines are provided by open collector outputs.
Protection:
The units are fully protected against over voltage, over current, over
temperature, load arcing and output short circuits. The ACE system
can be installed to give added arc management functionality.
Safety:
The OL20K high voltage power supplies meet the requirements of the
Low Voltage Directive, LVD, 73/23/EEC by complying with BS EN61010-
1:2001 when installed as a component part of other equipment. They
are CE marked accordingly.
RoHS:
The OL20K is currently built to non-RoHS standard. This unit can,
however, be configured to meet the requirements of RoHS where
significant customer demand requires it, although please note that this
will have an impact on delivery timescales.
Mechanical Specification:
Dimensions: See outline drawings.
Weight:
Converter 64kg (141 lb).
Stack - see table
Connections: All connections are mounted on the rear panel.
HV Output: M5 bush mounted on HV unit.
Front Panel: Stoving enamel trimite semi-gloss S60/6 colour cream
R87177 as standard.
Outputs and Ordering Information:
Model no
(208VAC input)
OL20K/603*
OL20K/803*
OL20K/104*
OL20K/124*
OL20K/144*
OL20K/164*
OL20K/184*
OL20K/204*
Model no
(400VAC input)
OL20KE/603*
OL20KE/803*
OL20KE/104*
OL20KE/124*
OL20KE/144*
OL20KE/164*
OL20KE/184*
OL20KE/204*
Output
Voltage
60kV
80kV
100kV
120kV
140kV
160kV
180kV
200kV
Output
Current
250mA
240mA
200mA
160mA
130mA
110mA
90mA
80mA
HV Stack
Weight
78kg
86.5kg
95kg
103.5kg
112kg
120.5kg
129kg
137.5kg
* Please add the required suffix to the part number:
P
N
R
Positive polarity
Negative polarity
Arc Count and Extinguish (ACE) system
eg OL20KE/803PR for an 80kV positive polarity unit with ACE system and
400VAC input voltage.
Interface Connections:
25-way D-type connector:
V STATUS INDICATOR
I STATUS INDICATOR
HV OUTPUT VOLTAGE MONITOR
TRIP INDICATOR
LOCAL INDICATOR
HV ON INDICATION
PROGRAM VOLTAGE MONITOR
HV ON Lo
HV ON Hi
PROGRAM VOLTAGE Hi
PROGRAM VOLTAGE Lo
0V
0V
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
HV OUTPUT CURRENT MONITOR
HV OFF INDICATOR
REMOTE INDICATOR
RESERVED
+10V REFERENCE VOLTAGE
RESERVED
RESERVED
ENABLE Lo
ENABLE Hi
CURRENT PROGRAM 0V
CURRENT PROGRAM
RESERVED
w w w. h i t e k p o w e r. c o m
Drawing dimensions are in mm (inches)
These component power supplies meet the requirements of EC Directive 73/23/EEC (LVD)
Design developments may result in specification changes
295.2 (11.62)
196.8 (7.75)
85.1 (3.35)
98.4 (3.87)
SLIDE FIXING M5 TANK BUSH
BOTH SIDES.
121.0 (4.76)
393.6 (15.50)
37.7 (1.48)
3 (0.12)
558 (21.97)
FEEDBACK
USER INTERFACE
8.8 (0.35)
AIR FLOW
AIR FLOW
190.5 (7.5)
HV.ON HV.OFF
TRIP
w w w. h i t e k p o w e r. c o m
(CASE)
439 (17.28)
429.8 (16.92)
AIR FLOW
AIR FLOW
AIR FLOW
AIR FLOW
AIR FLOW
OVER SCREW HEADS
40 (1.57)
482.6 (19)
20kW HIGH VOLTAGE POWER SUPPLY
465.0 (18.31)
AIR FLOW
265.9 (10.47)
Series OL20K
4 SLOTS
7 x 10.3
(0.28 x 0.41)
Series OL20K
20kW HIGH VOLTAGE POWER SUPPLY
OUTPUT kV
60
80
100
120
140
160
180
200
DIM 'A' NOMINAL
313.0 (MAX), 303.0 (MIN) (12.32 (MAX), 11.93 (MIN))
365.0 (MAX), 353.0 (MIN) (14.37 (MAX), 13.90 (MIN))
15 (0.59)
417.0 (MAX), 403.0 (MIN) (16.42 (MAX), 15.87 (MIN))
470.0 (MAX), 453.0 (MIN) (18.50 (MAX), 17.83 (MIN))
522.0 (MAX), 503.0 (MIN) (20.56 (MAX), 19.80 (MIN))
574.0 (MAX), 553.0 (MIN) (22.60 (MAX), 21.77 (MIN))
243 (9.57)
626.0 (MAX), 603.0 (MIN) (24.65 (MAX), 23.74 (MIN))
678.0 (MAX), 653.0 (MIN) (26.69 (MAX), 25.71 (MIN))
AIR FLOW
516 (20.31)
486 (19.13)
15 (0.59)
283 (11.14)
260 (10.24)
856 (33.70)
826 (32.52)
5mm RIVET
BUSH
4mm BANANA
SOCKET
5.4/5.6 DIA HOLE
(0.21/0.22 DIA)
14.5 (0.57) TYP.
FLANGE
10 OFF
8.8/9.0 DIA HOLE
(0.34/0.35 DIA)
740 (29.13)
410 (16.14)
320 (12.60)
650 (25.59)
628 (24.72)
HEIGHT INCLUSIVE OF
FIXINGS
83 (3.27)
50 (1.97)
DIM 'A'
235 (9.25)
31 (1.22)
9.5 (0.37)
FEEDBACK
M8 EARTH
STUD
37 (1.46)
Design developments may result in specification changes
42 (1.65)
38 (1.50)
300 DIA (11.81 DIA)
105 (4.13)
306 (12.05)
104 (4.09)
Drawing dimensions are in mm (inches)
160 (6.30)
73 (2.87)
613 (24.13)
45 (1.77)
121.5 (4.78)
w w w. h i t e k p o w e r. c o m
95 (3.74)
172 (6.77)
e-mail: sales.uk@hitekpower.com
GERMANY
HiTek Power GmbH
Joh.-Friedr.-Boettger-Str. 21
D-63322 Roedermark
Germany
Tel:
+49 (0) 6074 69285 0
Fax:
+49 (0) 6074 69285 10
UK
HiTek Power Ltd
Hawthorn Road, Littlehampton
West Sussex BN17 7LT
UK
Tel:
+44 (0) 1903 712400
Fax:
+44 (0) 1903 712500
e-mail: sales.us@hitekpower.com
JAPAN
HiTek Power Japan
1-5-13 Kyutaroumachi
Chou-ku, Osaka 541-0056
Japan
Tel:
+81 (6) 6271 8180
Fax:
+81 (6) 6271 8190
USA
HiTek Power Inc
124 Jewett Street, Unit #2
Georgetown, MA 01833-1868
USA
Tel:
+1 (978) 352-9100
Fax:
+1 (978) 352-9133
e-mail: sales.de@hitekpower.com
e-mail: info@hitekpowerjapan.co.jp
Issue 5: 11/2012
w w w. h i t e k p o w e r. c o m
查看更多>
红外遥控六足爬虫
本帖最后由 paulhyde 于 2014-9-15 09:10 编辑 在论坛上这么久了,下了不...
tmstd 电子竞赛
单片机读写保护怎么办
单片机读写保护怎么办 配置上的问题吧。 ...
犹太人QQ TI技术论坛
占空比设置问题
28335里面,EPwm2Regs.CMPA.half.CMPA = 0.5*Tcon;这种语句,...
lzx_18570633112 DSP 与 ARM 处理器
有谁拆过中国银行网银的口令牌么?
中国银行的口令牌,到期时间是10/31/11,也就是今天,我一时去不了开办地重新领一个,我想着应该是...
wangfuchong 微控制器 MCU
RF电路的PCB设计技巧
如今PCB的技术主要按电子产品的特性及要求而改变,在近年来电子产品日趋多功能、精巧并符合环保条例。...
ohahaha PCB设计
《电子工程师必备_九大系统电路识图宝典》
给大家分享一本书:《电子工程师必备_九大系统电路识图宝典》有需要的童鞋欢迎下载!(资料仅供学习交流使...
szjlcgw 模拟电子
热门器件
热门资源推荐
器件捷径:
S0 S1 S2 S3 S4 S5 S6 S7 S8 S9 SA SB SC SD SE SF SG SH SI SJ SK SL SM SN SO SP SQ SR SS ST SU SV SW SX SY SZ T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 TA TB TC TD TE TF TG TH TI TJ TK TL TM TN TO TP TQ TR TS TT TU TV TW TX TY TZ U0 U1 U2 U3 U4 U6 U7 U8 UA UB UC UD UE UF UG UH UI UJ UK UL UM UN UP UQ UR US UT UU UV UW UX UZ V0 V1 V2 V3 V4 V5 V6 V7 V8 V9 VA VB VC VD VE VF VG VH VI VJ VK VL VM VN VO VP VQ VR VS VT VU VV VW VX VY VZ W0 W1 W2 W3 W4 W5 W6 W7 W8 W9 WA WB WC WD WE WF WG WH WI WJ WK WL WM WN WO WP WR WS WT WU WV WW WY X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XE XF XG XH XK XL XM XN XO XP XQ XR XS XT XU XV XW XX XY XZ Y0 Y1 Y2 Y4 Y5 Y6 Y9 YA YB YC YD YE YF YG YH YK YL YM YN YP YQ YR YS YT YX Z0 Z1 Z2 Z3 Z4 Z5 Z6 Z8 ZA ZB ZC ZD ZE ZF ZG ZH ZJ ZL ZM ZN ZP ZR ZS ZT ZU ZV ZW ZX ZY
需要登录后才可以下载。
登录取消