P
Series
The Chameleon
Adaptable Module
for General or Medical Applications
UL Recognized
CSA Certified
VDE Approved
PS Unfiltered
PE Filtered
with “A” Shield
PS Filtered
P Series
The P series power entry module offers full flexibility of
design in the most compact package.
As the first 10 amp module to provide all five power entry
functions in one compact design, the P Series readily
adapts to its environment and the needs of international
markets.
• Snap-in or flange mounting
• I E C power line connector
• Both North American and European fusing capabilities
• Two voltage selection
• Optional DPST on/off switch
• Filtering options for general purpose and medical
applications.
The P Series compact design and modular construction
will allow you to select all the power entry features you
require – without altering the panel cutout. And the P
Series, with adapters, will fit any standard panel cutout
you currently have designed.
H Models
- Designed to help equipment meet UL544,
UL2601 and EN60601 for patient care equipment and
non-patient care equipment in medical applications, these
filters provide susceptibility protection without leakage
current associated with line-to-ground capacitors. They
are available with current ratings of 3, 6 and 10 amps.
B Models
- Included with these models is an
interconnection block that reduces external wiring by
connecting the switch with the fuse(s) and IEC receptacle.
They are rated for applications up to 10 amps.
Z Models
- High performance filter versions are designed
to help bring most digital equipment (including switching
power supplies) into compliance with EN55022, Level B
(as well as FCC Part 15J, Class B) conducted emissions
limits. They are available with current ratings of 6 and 10
amps. High performance versions are available with
horizontal mounting ears, no extenders, single voltage,
complete can shield with options for switch, fuses and
current ratings only.
L Models
- High performance Medical filter versions that
are designed to help bring most digital equipment
(including switching power supplies) into compliance with
EN55022, Level B (as well as FCC Part 15J, Class B)
conducted emissions limits while additionally allowing
equipment to meet UL544, UL2601 and EN60601 for
patient care equipment and non-patient care equipment.
They are available with current ratings of 6 and 10 amps.
High performance versions are available with horizontal
mounting ears, no extenders, single voltage, complete
can shield with options for switch, fuses and current
ratings only.
The P Series is available with a variety of filtering options:
O Models
- This version does not include an RFI filter, but
has all other options of the P Series. They are rated for
applications up to 10 amps.
S Models
- General purpose applications where line-to-
ground and line-to-line noise must be controlled. These
filters allow compliance with FCC limits for linear power
supplies. They are available with current ratings of 3, 6,
10 amps.
www.cor.com - Libertyville, IL (847) 680-7400
Series
P Series Part Number System
Part numbers are constructed by selecting the alphanumeric character which represents the desired feature.
P
P
Series
Mounting Style
E
= Mounting ears
(horizontal)
M
= Mounting ears
(vertical)
S
= Snap-in
Extender
Options
1
0
= None
C
= FN260
J
= J Series
L
= L series
Switch Options
0
= No switch
S
= Double pole
single throw
(DPST)
Input Voltage Select
0
= Single AC voltage
S
= Dual AC voltage
select (SMPS)
X =
Dual AC voltage
select (series/parallel)
Fuse Options
D
= Dual fuse
S
= Single fuse
Filter Type
3 ,
4
Filter Current
3
0
= No filter or
interconnection
block
3
= 3 amps
6
= 6 amps
X
= 10 amps
Shield Options
2, 3
0
= No filter
B
= Interconnection
block
H
= Medical
L
= Medical high
performance
S
= General purpose
Z
= High performance
0
= No shield
A
= Filter shield
B
= Complete
shield
C
= Complete can
(High performance
version)
Notes:
1
Extenders cannot be added to units with B or C shields.
Extenders allow the P Series to fit other Corcom/competitor
panel cutouts.
2
Shields can only be used with filtered models.
3
When using interconnection block, the last 3 digits of the
part number are BX0.
4
High performance versions are available with horizontal
mounting ears, no extenders, single voltage, complete can
shield with options for switch, fuses, filter type (L or Z) and
current ratings only.
(e.g PE0 _ S _ _ _C)
P S J 0 X S S 6 0
No Shield
6A current
General purpose filter
Single fusing
Dual voltage select
(series/parallel)
No switch
J extender
Snap-in mount
P Series
Ordering Information
Consult your local Corcom sales representative for pricing.
Most Popular Part numbers
(Contact factory for availability of component combinations not listed)
Filtered
PE00XDS60
PE0S0SS6B
PE0SSSS60
PE0S0DLXC
PE0S0DL6C
PE0S0DZXC
PE0S0DZ6C
PE0S0SLXC
PE0S0SL6C
PE0S0SZXC
PE0S0SZ6C
PS000D000
PS000S000
PS000SH30
PS000SS3B
PS000SS60
PS000SS6B
PS000SSXB
PS00XD000
PS00XS000
PS0S0D000
PS0S0DBX0
PS0S0DH3B
PS0S0DHX0
PS0S0DS60
PS0S0DS6A
PS0S0DS6B
PS0S0S000
PS0S0SBX0
PS0S0SH60
PS0S0SH6B
PS0S0SHXA
PS0S0SS3A
PS0S0SS3B
PS0S0SS60
PS0S0SS6A
PS0S0SSXB
PS0SSSH30
PS0SXD000
PS0SXDH30
PS0SXDH3A
PS0SXDH60
PS0SXDH6A
PS0SXDS30
PS0SXDS3A
PS0SXDS60
PS0SXDS6B
PS0SXS000
PS0SXSH30
PS0SXSH6A
PS0SXSS30
PS0SXSS60
PS0SXSS6A
PS0SXSS6B
PS0SXSSX0
PSJS0DH30
PSJS0S000
PSJSXS000
Unfiltered
PE0SSS000
PSJSXS000
PSJS0S000
PSJ0XD000
PSJ0XS000
PS0SSD000
PS0SSS000
PS0SXD000
PS0SXS000
PS0S0D000
PS0S0S000
PS00SD000
PS00SS000
PS00XD000
PS00XS000
PS000D000
PS000S000
Mounting Styles
Corcom offers both flange mounting as well as snap-in
mounting of the popular P Series. This allows OEM’s to
choose the part that best suits their production
methods.
Extender Option
Extenders are available which allow the P series to
adapt to Corcom’s L or J series cutouts, as well as the
panel cutout of Schaffner and Delta parts (C extender).
Flange Mount
Snap-in Mount
eg. The ‘J’ extender will allow the ‘P’ series to fit the
Corcom ‘J’ series cutout
Libertyville, IL (847) 680-7400 - www.cor.com
P
Series
applications. The voltage selector installed will allow
proper wiring from these applications. No matter what
voltage selection scheme is used, wiring is always made
to the same four terminals.
Fuse / Fuseholder Options
Another feature of the P series power entry module is a
versatile fusing arrangement. Its fuseholder can hold
two 1/4” x 1-1/4” or 5 x 20mm fuses. It can also be
converted to accept one fuse with a conversion clip that
bridges one of the two fuse chambers.
The conversion clip is installed on the P Series power
entry modules set for single fusing, those with part
numbers with an “S” as the sixth digit. Units with a “D”
as the sixth digit do not include a conversion clip.
Extenders cannot be added to units with B or C shields.
Switch Option
Both switched (DPST) and unswitched wiring of the P
Series are available.
Input Voltage Select
The P series of power entry modules provides a dual
voltage selector which is integrated with the fuseholder.
To simplify the wiring in each individual application,
Corcom provides dedicated voltage selectors for different
voltage selection schemes. The two most popular
schemes are series/parallel for dual primary transformers
and the “DPST switch” for switching mode power supplies
(jumper types.) P series products with an “S” as the fifth
digit are specifically designed for “jumper” type
applications associated with switching mode power
supplies.
1) Dual Primary Transformer Type:
Shown is the fuseholder with a fuse held in the proper
manner.
Note that the back end of the fuse slightly
pretrudes out of the fuseholder in order to make
contact with a terminal inside the power entry
module.
Filter Type
Six options are available for the filter type: general
purpose, medical applications, high performance, high
performance medical as well as an unfiltered and
unfiltered with an interconnection block.
Filtered versions
include the S Models which are
designed for general purpose applications where line-to-
ground and line-to-line noise must be controlled. Z
Models are a high performance filter designed to help
bring most digital equipment (including switching power
supplies) into compliance with EN55022, Level B (as well
as FCC Part 15J, Class B) conducted emissions limits.
H Models are the medical version of the S models and
are designed to help equipment meet UL544, UL2601
and EN60601 for patient and non-patient care equipment
in medical applications. L Models are the medical
version of the Z models (high performance) that are
designed to additionally allow equipment to meet UL544,
UL2601 and EN 60601 for patient and non-patient care
equipment.
S Model
(Voltage selection not available on L or Z models)
P series products with an “X” as the fifth digit are
specifically designed for dual primary transformer
2) Jumper Type
Note 1: Jumpers are required if a filter or interconnection
module is not used.
Note 2: Location of optional filter. Jumpers are required if a filter or
interconnection module is not used.
www.cor.com - Libertyville, IL (847) 680-7400
Series
H Model
P
Z Model
allowing the use of the P Series extender. The B shield
covers the entire power entry module with metal,
protecting the equipment from all radiated noise. Used
with the filter, the shield provides the most secure
protection from RFI noise problems. The B shield cannot
be used with any extender.
Specifications – Filtered Models
Minimum
insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating .03 .1 .15 .5
1
3
S Models
3A
7
6A
10A
H Models
3A
7
6A
10A
3
17
8
3
17
8
5
21
12
5
21
11
8
27
17
10
27
15
10
33
23
13
30
17
12
40
32
23
29
19
11
L Model
5
44
36
27
26
18
11
10
50
44
35
23
16
10
30
32
30
27
15
13
10
Unfiltered versions
of the P series includes a standard
version (0 Models) that does not have an RFI filter, but
does have all other options of the P Series. It also
includes an interconnection block version (B Models)
which provides wiring of the IEC socket to the switch and
the switch to the fuseholder. Labor can be eliminated by
ordering the product with an interconnection block. This
feature, designated by a BX0 at the end of the part
number, prewires the module for easier installation. The
wiring is protected with the plastic case to prevent
access to the terminals and connections. Wiring can be
further simplified by ordering a PA100 connector
assembly, as shown in the accessories section. The
dimensions of this alternative are the same as the filtered
versions.
Line-to-ground in 50 ohm circuit
Current
Frequency-MHz
Rating .01 .05 .1 .15 0.5 1
Z Models
6A
10A
L Models
6A
10A
8
5
8
5
21
17
21
17
27
22
27
22
30
24
29
23
37
27
34
24
43
32
35
25
5
49
52
25
21
10
52
47
21
18
30
42
40
16
14
Filter Current
The P Series is available without a filter (10A rating) or in
3, 6 and 10 ampere filtered versions.
Shield Options
A feature available on the P series is an RF shield. The
metal shield, available on filtered models, provides
shielding from radiated emissions and provides an
additional RF ground for the filter to the case.
The shield is available in two versions, a shield of the filter
components (designated by A as the ninth digit) and a
complete shield (designated by B as the ninth digit).
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating
.10 .15
.5
1
3
5
S Models
3A
6A
10A
H Models
3A
6A
10A
10
30
2
2
2
2
2
2
4
4
4
4
4
4
12
12
12
12
12
12
15
15
15
18
16
16
30
22
22
31
26
26
48
42
42
40
35
33
50
55
55
48
40
40
45
45
45
41
35
32
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating .01 .05 .1 .15 0.5 1
Z Models
6A
10A
L Models
6A
10A
10
10
10
10
15
20
15
20
34
20
34
20
44
35
44
35
75
67
75
67
75
75
75
75
5
75
75
75
75
10
70
70
70
70
30
60
60
60
60
A Shield
B Shield
The A shield covers the filter portion of the module and
increases performance of the filter by protecting the
components from magnetic coupling. This shield
improves RF ground connection to the case while still
Libertyville, IL (847) 680-7400 - www.cor.com
P
Series
Case Dimensions — Unfiltered Models
Metric shown in italics.
1500 VAC
1450 VDC
50/60 Hz
120/250 VAC
10A @ 120 VAC
10A @ 250 VAC
115/230 VAC
1/4” x 1-1/4”
or 5 x 20 mm
PE
PS
PSC
PSJ
PSL
Part No.
A
B
C
(max) (max) (max)
1.98 1.93
50.29 49.02
1.24 1.93
31.49 49.02
1.24 1.93
31.49 49.02
1.24 1.93
31.49 49.02
1.24 1.93
31.49 49.02
(+.008
-.000)
Specifications – Unfiltered Models
Hipot rating (one minute):
line-to-ground
line-to-line
Operating frequency:
Rated voltage:
Rated current, all unfiltered models:
Operating voltages:
Selectable or fixed
Fuseholder:
Accepts one or two fuses*
Switch:
D
(+.008
-.000)
E
F
2.31 1.122 2.201 1.575
58.67 28.5 55.91 40.0
2.31 1.06 2.201*
58.67 26.93 55.91
2.81 1.06 2.52
63.75 26.92 64.01
2.72 1.06
2.6 +
69.09 26.92 66.0
2.31 1.12 2.201*
58.67 28.45 55.91
Double-insulated rated for 10,000
operations at full load.
51 Amp inrush capability.
0.187” x 0.032” terminal tabs
Terminals:
*
Panel cutout for thickness of .031 - .079
(.80 - 2.0).
For panel thickness
.083-.114
(2.1-2.9)
use 2.213
(56.21).
+ Panel cutout for thickness of 0.06-0.09
(0.76 - 2.29).
*Conversion clip provided on fuseholder for single fuse
models.
Case Styles - Unfiltered Models
Metric shown in italics.
PS/PSL
PE
Mounting holes
.125
Dia. (2) Countersunk holes
3.18
PSC/PSJ
Back View
Typical Panel Cutout
*
For snap-in applications, the D sides of the cutout must
have a .02 (.508) radius on the installation side.
Note: Snap-in models allow front mounting only. PS not
recommended for plastic panels.
www.cor.com - Libertyville, IL (847) 680-7400