S−AU27AL,S−AU27AM,S−AU27AH
TOSHIBA RF POWER AMPLIFIER MODULE
S−AU27AL,S−AU27AM,S−AU27AH
25W FM RF POWER AMPLIFIER MODULE
Unit in mm
l
S-AU27AL
l
S-AU27AM
l
S-AU27AH
: f = 400~430MHz
: f = 450~490MHz
: f = 490~512MHz
MAXIMUM RATINGS
(Tc = 25°C)
CHARACTERISTIC
DC Supply Voltage
DC Supply Voltage
DC Supply Voltage
Total current
Input Power
Output Power
Operating Case Temperature Range
Storage Temperature Range
SYMBOL
V
CC1
V
CC2
V
CC3
I
T
P
i
P
o
T
c (opr)
T
stg
RATING
16
17
17
10
600
40
−30~100
−40~110
UNIT
V
V
V
A
mW
W
°C
°C
JEDEC
EIAJ
TOSHIBA
Weight: 35g
—
—
5−53Q
ELECTRICAL CHARACTERISTICS
(Tc = 25°C)
CHARACTERISTIC
Frequency Range
Output Power
Power Gain
Total Efficiency
Input VSWR
Harmonics
SYMBOL
f
range
Po
G
p
η
T
VSWRin
HRM
Po = 35W (V
CC1
= adjust)
V
CC2
= V
CC3
=
15V
Pi = 200mW
VSWR load 20:
1
all phase
V
CC2
= V
CC3
=
12.5V
V
CC1
= 3~12.5V
Pi = 200mW
VSWR load 3:
1
all phase
TEST CONDITION
―
MIN.
400
32
TYP.
—
—
—
—
1.5
−30
MAX.
512
—
—
—
2.5
−25
UNIT
MHz
W
dB
%
—
dB
V
CC1
= V
CC2
= V
CC3
=
12.5V
Pi = 200mW
Z
G
= Z
L
= 50Ω
22.0
35
—
—
Load Mismatch
—
No Degradation
―
Stability
—
All spurious output than
60dB below desired
signal
―
000707EAA2
·
TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general
can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the
buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and
to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or
damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the
most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the “Handling
Guide for Semiconductor Devices,” or “TOSHIBA Semiconductor Reliability Handbook” etc..
2001-02-02
1/3
S−AU27AL,S−AU27AM,S−AU27AH
CAUTION
·
This product has intersetting cap. Please pay attention for exceeding stress and foreign matter in your application.
And not to take away the cap.
·
Beryllia Ceramics is used in this product. The dust or vapor can be dangerous to humans. Do not break, cut, crush
or dissolve chemically. Dispose of this product properly according to law. Do not intermingle with normal industrial
or domestic waste.
SCHEMATIC
TEST FIXTURE
000707EAA2
·
The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal
equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are
neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or
failure of which may cause loss of human life or bodily injury (“Unintended Usage”). Unintended Usage include atomic energy
control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control
instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document
shall be made at the customer’s own risk.
·
The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by
TOSHIBA CORPORATION for any infringements of intellectual property or other rights of the third parties which may result from its
use. No license is granted by implication or otherwise under any intellectual property or other rights of TOSHIBA CORPORATION or
others.
·
The information contained herein is subject to change without notice.
2001-02-02
2/3
S−AU27AL,S−AU27AM,S−AU27AH
CAUTION
These are only typical curves and devices are not necessarily guaranteed at these curves.
2001-02-02
3/3