首页 > 器件类别 > 无源元件 > 电阻器

V130LS5

RESISTOR, VOLTAGE DEPENDENT, 175V, 20J, THROUGH HOLE MOUNT

器件类别:无源元件    电阻器   

厂商名称:Intersil ( Renesas )

厂商官网:http://www.intersil.com/cda/home/

下载文档
器件参数
参数名称
属性值
是否Rohs认证
不符合
Reach Compliance Code
not_compliant
ECCN代码
EAR99
电路直流最大电压
175 V
电路RMS最大电压
130 V
最大能量吸收容量
20 J
安装特点
THROUGH HOLE MOUNT
封装形式
Radial
电阻器类型
VARISTOR
表面贴装
NO
技术
METAL OXIDE FILM
文档预览
LA Series
Data Sheet
July 1999
File Number
2190.6
Radial Lead Metal-Oxide Varistors for Line
Voltage Operation
[ /Title
(LA
Series)
/Sub-
ject
(Radial
Lead
Metal-
Oxide
Varis-
tors for
Line
Volt-
age
Opera-
tion)
/Autho
r ()
/Key-
words
(Har-
ris
Corpo-
ration,
Sup-
pres-
sion
Prod-
ucts,
TVS,
Tran-
sient
Sup-
pres-
sion,
Protec-
tion,
AC
Line,
The LA Series of transient voltage surge suppressors are
radial-lead varistors (MOVs) that are designed to be
operated continuously across AC power lines. These UL
recognized varistors require very little mounting space, and
are offered in various standard lead form options.
The LA Series varistors are available in four model sizes:
7mm, 10mm, 14mm and 20mm; and have a V
M(AC)RMS
voltage range from 130V to 1000V, and an energy
absorption capability up to 360J. Some LA series model
numbers are available with clamping voltage selections,
designated by a model number suffix of either A or B. The
“A” selection is the standard model; the “B” selection
provides a lower clamping voltage.
See LA Series Device Ratings and Specifications table for
part number and brand information.
Features
• Recognized as “Transient Voltage Surge Suppressors”, UL
File #E75961 to Standard 1449, Second Edition
• Recognized as “Across-The-Line Components”, UL File
#E56529 to Standard 1414
• Recognized as “Protectors for Data Communication and
Fire Alarm Circuits”, UL File #E135010 to
Standard 497B
• VDE Certified. License Number 116895E
• CECC Certified (42201-006)
• Recognized as “Transient Voltage Surge Suppressors”,
CSA File #LR91788 to Standard C22.2 No. 1 - M1981
• Energy Absorption Capability (W
TM
) . . . . . . . Up to 360J
• Wide Operating Voltage Range
V
M(AC)RMS
. . . . . . . . . . . . . . . . . . . . . . . . . 130V to 1000V
• No Derating Up to 85
o
C Ambient
• Available in Tape and Reel or Bulk Pack
Packaging
14MM, 20MM
7MM, 10MM
4-24
1-800-4-HARRIS or 407-727-9207
|
Copyright
©
Harris Corporation 1999
LA Series
Absolute Maximum Ratings
For ratings of individual members of a series, see Device Ratings and Specifications chart
LA SERIES
Continuous:
Steady State Applied Voltage:
AC Voltage Range (V
M(AC)RMS
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DC Voltage Range (V
M(DC)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transients:
Peak Pulse Current (I
TM
)
For 8/20µs Current Wave (See Figure 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Pulse Energy Range
For 10/1000µs Current Wave (W
TM
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Ambient Temperature Range (T
A
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage Temperature Range (T
STG
) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Temperature Coefficient (αV) of Clamping Voltage (V
C
) at Specified Test Current . . . . . . . . . . . . . . . . . .
Hi-Pot Encapsulation (Isolation Voltage Capability) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(Dielectric must withstand indicated DC voltage for one minute per MIL-STD 202, Method 301)
Insulation Resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNITS
130 to 1000
175 to 1200
V
V
1200 to 6500
11 to 360
-55 to 85
-55 to 125
<0.01
2500
1000
A
J
o
C
o
C
%/
o
C
V
MΩ
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the
device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
Series LA Varistors are certified by VDE under License Number 116895E.
Series LA Varistors are listed under UL file #E75961 and E56529 as a recognized component.
Series LA Varistors are listed under CSA file #LR91788 as a recognized component.
Device Ratings and Specifications
MAXIMUM RATING (85
o
C)
CONTINUOUS
TRANSIENT
ENERGY
10 x 1000µs
W
TM
(J)
11
11
20
38
70
70
12
22
42
75
13
13
25
45
80
80
15
30
55
90
20
35
70
122
PEAK
CURRENT
8 x 20µs
I
TM
(A)
1200
1200
2500
4500
6500
6500
1200
2500
4500
6500
1200
1200
2500
4500
6500
6500
1200
2500
4500
6500
1200
2500
4500
6500
184
184
184
184
184
184
198
198
198
198
212
212
212
212
212
212
247
247
247
247
324
324
324
324
VARISTOR VOLT-
AGE AT 1mA DC
TEST CURRENT
V
NOM
MIN
(V)
255
228
228
228
228
220
242
242
242
242
284
268
268
268
268
243
303
303
303
303
396
396
396
396
V
NOM
MAX
SPECIFICATIONS (25
o
C)
MAXIMUM
CLAMPING
VOLTAGE
8 x 20µs
V
C
(V)
390
340
340
340
340
325
360
360
360
340
430
395
395
395
395
360
455
455
455
455
595
595
595
595
I
PK
(A)
10
10
25
50
100
100
10
25
50
100
10
10
25
50
100
100
10
25
50
100
10
25
50
100
TYPICAL
CAPACI-
TANCE
f = 1MHz
C
(pF)
180
180
450
1000
1900
1900
160
400
900
1750
150
150
360
800
1600
1600
130
350
700
1400
100
250
550
1100
PART
NUMBER
V130LA1
V130LA2
V130LA5
V130LA10A
V130LA20A
V130LA20B
V140LA2
V140LA5
V140LA10A
V140LA20A
V150LA1
V150LA2
V150LA5
V150LA10A
V150LA20A
V150LA20B
V175LA2
V175LA5
V175LA10A
V175LA20A
V230LA4
V230LA10
V230LA20A
V230LA40A
MODEL
SIZE
DISC
DIA.
(mm)
7
7
10
14
20
20
7
10
14
20
7
7
10
14
20
20
7
10
14
20
7
10
14
20
DEVICE
MODEL
NUMBER
BRAND-
ING
1301
1302
1305
130L10
130L20
130L20B
1402
1405
140L10
140L20
1501
1502
1505
150L10
150L20
150L20B
1752
1755
175L10
175L20
2304
230L
230L20
230L40
V
RMS
V
M(AC)
(V)
130
130
130
130
130
130
140
140
140
140
150
150
150
150
150
150
175
175
175
175
230
230
230
230
V
DC
V
M(DC)
(V)
175
175
175
175
175
175
180
180
180
180
200
200
200
200
200
200
225
225
225
225
300
300
300
300
4-25
LA Series
Device Ratings and Specifications
(Continued)
MAXIMUM RATING (85
o
C)
CONTINUOUS
TRANSIENT
ENERGY
10 x 1000µs
W
TM
(J)
21
21
40
72
130
130
23
23
45
75
140
140
25
25
46
77
165
25
48
80
150
27
51
85
160
30
55
90
160
37
35
60
105
180
63
110
190
65
120
220
67
125
230
PEAK
CURRENT
8 x 20µs
I
TM
(A)
1200
1200
2500
4500
6500
6500
1200
1200
2500
4500
6500
6500
1200
1200
2500
4500
6500
1200
2500
4500
6500
1200
2500
4500
6500
1200
2500
4500
6500
1200
1200
2500
4500
6500
2500
4500
6500
2500
4500
6500
2500
4500
6500
354
354
354
354
354
354
389
389
389
389
389
389
420
420
420
420
420
462
462
462
462
558
558
558
558
610
610
610
610
702
670
670
670
670
735
735
735
805
805
805
940
940
940
VARISTOR VOLT-
AGE AT 1mA DC
TEST CURRENT
V
NOM
MIN
(V)
473
429
429
429
429
413
515
473
473
473
473
453
565
517
517
517
517
565
565
565
540
682
682
682
682
748
748
748
720
858
825
825
825
790
910
910
860
1000
1000
960
1210
1210
1100
V
NOM
MAX
SPECIFICATIONS (25
o
C)
MAXIMUM
CLAMPING
VOLTAGE
8 x 20µs
V
C
(V)
730
650
650
650
650
620
775
710
710
710
710
680
870
775
775
775
775
850
850
850
810
1025
1025
1025
1025
1120
1120
1120
1060
1130
1240
1240
1240
1160
1350
1350
1280
1500
1500
1410
1820
1820
1650
I
PK
(A)
10
10
25
50
100
100
10
10
25
50
100
100
10
10
25
50
100
10
25
50
100
10
25
50
100
10
25
50
100
10
10
25
50
100
25
50
100
25
50
100
25
50
100
TYPICAL
CAPACI-
TANCE
f = 1MHz
C
(pF)
90
90
220
500
1000
1000
80
80
200
450
900
900
70
70
180
400
800
65
170
380
750
60
160
360
700
55
140
300
600
55
270
120
270
550
100
250
500
90
220
450
80
210
425
PART
NUMBER
V250LA2
V250LA4
V250LA10
V250LA20A
V250LA40A
V250LA40B
V275LA2
V275LA4
V275LA10
V275LA20A
V275LA40A
V275LA40B
V300LA2
V300LA4
V300LA10
V300LA20A
V300LA40A
V320LA7
V320LA10
V320LA20A
V320LA40B
V385LA7
V385LA10
V385LA20A
V385LA40B
V420LA7
V420LA10
V420LA20A
V420LA40B
V460LA7
V480LA7
V480LA10
V480LA40A
V480LA80B
V510LA10
V510LA40A
V510LA80B
V575LA10
V575LA40A
V575LA80B
V625LA10
V625LA40A
V625LA80B
MODEL
SIZE
DISC
DIA.
(mm)
7
7
10
14
20
20
7
7
10
14
20
20
7
7
10
14
20
7
10
14
20
7
10
14
20
7
10
14
20
7
7
10
14
20
10
14
20
10
14
20
10
14
20
DEVICE
MODEL
NUMBER
BRAND-
ING
2502
2504
250L
250L20
250L40
250L40B
2752
2754
275L
275L20
275L40
275L40B
3002
3004
300L
300L20
300L40
3207
320L
320L20
320L40
3857
385L
385L20
385L40
4207
420L
420L20
420L40
4607
4807
480L
480L40
480L80
510L
510L40
510L80
575L
575L40
575L80
625L
625L40
625L80
V
RMS
V
M(AC)
(V)
250
250
250
250
250
250
275
275
275
275
275
275
300
300
300
300
300
320
320
320
320
385
385
385
385
420
420
420
420
460
480
480
480
480
510
510
510
575
575
575
625
625
625
V
DC
V
M(DC)
(V)
330
330
330
330
330
330
369
369
369
369
369
369
405
405
405
405
405
420
420
420
420
505
505
505
505
560
560
560
560
615
640
640
640
640
675
675
675
730
730
730
825
825
825
4-26
LA Series
Device Ratings and Specifications
(Continued)
MAXIMUM RATING (85
o
C)
CONTINUOUS
TRANSIENT
ENERGY
10 x 1000µs
W
TM
(J)
70
140
250
220
360
PEAK
CURRENT
8 x 20µs
I
TM
(A)
2500
4500
6500
4500
6500
940
940
940
1425
1425
VARISTOR VOLT-
AGE AT 1mA DC
TEST CURRENT
V
NOM
MIN
(V)
1210
1210
1100
1800
1600
V
NOM
MAX
SPECIFICATIONS (25
o
C)
MAXIMUM
CLAMPING
VOLTAGE
8 x 20µs
V
C
(V)
1820
1820
1650
2700
2420
I
PK
(A)
50
50
100
50
100
TYPICAL
CAPACI-
TANCE
f = 1MHz
C
(pF)
70
200
400
130
250
PART
NUMBER
V660LA10
V660LA50A
V660LA100B
V1000LA80A
V1000LA160B
MODEL
SIZE
DISC
DIA.
(mm)
10
14
20
14
20
DEVICE
MODEL
NUMBER
BRAND-
ING
660L
660L50
660L100
1000L80
1000L160
V
RMS
V
M(AC)
(V)
660
660
660
1000
1000
V
DC
V
M(DC)
(V)
850
850
850
1200
1200
NOTE: Average power dissipation of transients not to exceed 0.25W, 0.4W, 0.6W or 1W for model sizes 7mm, 10mm, 14mm and 20mm, respectively.
Power Dissipation Ratings
Should transients occur in rapid succession, the average
power dissipation is the energy (watt-seconds) per pulse
times the number of pulses per second. The power so
developed must be within the specifications shown on the
Device Ratings and Specifications table for the specific
device. The operating values of a MOV need to be derated at
high temperatures as shown in Figure 1. Because varistors
only dissipate a relatively small amount of average power
they are not suitable for repetitive applications that involve
substantial amounts of average power dissipation.
1.
100
PERCENT OF RATED VALUE
90
80
70
60
50
40
30
20
10
0
-55
50
60
70
80
90
100
110
120
130
140 150
AMBIENT TEMPERATURE (
o
C)
FIGURE 1. CURRENT, ENERGY AND POWER DERATING
CURVE
PERCENT OF PEAK VALUE
100
90
50
O
1
= Virtual Origin of Wave
T = Time From 10% to 90% of Peak
T
1
= Virtual Front time = 1.25
t
T
2
= Virtual Time to Half Value (Impulse Duration)
Example: For an 8/20µs Current Waveform:
8µs = T
1
= Virtual Front Time
20µs = T
2
= Virtual Time to Half Value
10
O
1
T
T
1
T
2
TIME
FIGURE 2. PEAK PULSE CURRENT TEST WAVEFORM
4-27
LA Series
Transient V-I Characteristics Curves
6,000
5,000
4,000
MAXIMUM PEAK VOLTS (V)
3,000
2,000
V275LA2
V250LA2
1,000
900
800
700
600
500
400
300
V130LA1
200
10
-3
10
-2
10
-1
10
0
10
1
10
2
PEAK AMPERES (A)
10
3
10
4
100
10
-3
10
-2
10
-1
V300LA2
4,000
MAXIMUM CLAMPING VOLTAGE
MODEL SIZE 7mm
130 TO 300V
M(AC)
RATING
T
A
= -55
o
C TO 85
o
C
3,000
MAXIMUM PEAK VOLTS (V)
2,000
MAXIMUM CLAMPING VOLTAGE
MODEL SIZE 7mm
130 TO 300V
M(AC)
RATING
T
A
= -55
o
C TO 85
o
C
V300LA4
V275LA4
V250LA4
V230LA4
1,000
900
800
700
600
500
400
300
200
V175LA2
V150LA2
V140LA2
V130LA2
10
0
10
1
10
2
PEAK AMPERES (A)
10
3
10
4
V150LA1
FIGURE 3. CLAMPING VOLTAGE FOR V130LA1 - V300LA2
FIGURE 4. CLAMPING VOLTAGE FOR V130LA2 - V300LA4
MAXIMUM PEAK VOLTS (V)
3,000
MAXIMUM PEAK VOLTS (V)
MAXIMUM CLAMPING VOLTAGE
5,000 MODEL SIZE 7mm
320 TO 480V
M(AC)
RATING
T
A
= -55
o
C TO 85
o
C
6,000
5,000
4,000
3,000
2,000
MAXIMUM CLAMPING VOLTAGE
MODEL SIZE 10mm
130 TO 420V
M(AC)
RATING
T
A
= -55
o
C TO 85
o
C
V275LA10
V250LA10
V230LA10
V420LA10
2,000
V460LA7
V480LA7
1,000
V420LA7
V385LA7
V320LA7
500
10
-3
10
-2
10
-1
10
0
10
1
PEAK AMPERES (A)
10
2
10
3
10
4
1,000
900
800
700
600
500
400
300
V175LA5
V150LA5
V140LA5
V130LA5
10
-2
10
-1
10
0
10
1
10
2
PEAK AMPERES (A)
10
3
10
4
200
10
-3
FIGURE 5. CLAMPING VOLTAGE FOR V320LA7 - V480LA7
FIGURE 6. CLAMPING VOLTAGE FOR V130LA5 - V420LA10
MAXIMUM PEAK VOLTS (V)
3,000
2,000
V300LA10
V320LA10
V625LA10
V660LA10
MAXIMUM PEAK VOLTS (V)
MAXIMUM CLAMPING VOLTAGE
5,000 MODEL SIZE 10mm
300 TO 660V
M(AC)
RATING
T
A
= -55
o
C TO 85
o
C
6,000
5,000
4,000
3,000
2,000
MAXIMUM CLAMPING VOLTAGE
MODEL SIZE 14mm
130 TO 320V
M(AC)
RATING
T
A
= -55
o
C TO 85
o
C
V275LA20A
V250LA20A
V230LA20A
V300LA20A
V320LA20A
1,000
900
800
700
600
500
400
300
200
10
-3
1,000
V575LA10
V510LA10
V480LA10
V385LA10
10
-3
10
-2
10
-1
10
0
10
1
PEAK AMPERES (A)
10
2
10
3
10
4
V175LA10A
V150LA10A
V140LA10A
V130LA10A
10
-2
10
-1
10
0
10
1
10
2
PEAK AMPERES (A)
10
3
10
4
500
FIGURE 7. CLAMPING VOLTAGE FOR V300LA10 - V660LA10
FIGURE 8. CLAMPING VOLTAGE FOR V130LA10A - V320LA20A
4-28
查看更多>
Linux&intel386操作系统群,欢迎加入。
各位好!Linux&intel386操作系统群 刚刚成立!欢迎各位高手加入共同学习!我们的目标是,透...
xboy3721 Linux与安卓
大家帮我看看这个芯片为何不工作
我用的主控是51,晶振是12m 我用51控制语音芯片,语音芯片工作在三线串口模式,但是语音芯片根本就...
zhangkai0215 单片机
关于曼彻斯特码解码的问题
用STC15W404AS这款单片机写了个解码程序总是解不出来,有做过曼码解码程序的大神指点一下吗...
G28197 51单片机
【求助】怎么采集脉冲信号?
我用的是MSP430F1121,比如通过P2.5口采集10KHZ脉冲,怎么实现。用P口中断唤醒主程序...
kpbearmo 微控制器 MCU
电源滤波设计精华
电源滤波设计精华 电源滤波设计精华 回复 电源滤波设计精华 顶顶 正好需要。。。。 安规电容设计...
linda_xia 模拟电子
CC2530的开发环境搭建与快速入门攻略
本人学习和教学CC2530入门的经验总结。 对想入门的初学者应该很有用。 会让你们少走不少弯路。 ...
ohy3686 RF/无线
热门器件
热门资源推荐
器件捷径:
A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ B0 B1 B2 B3 B4 B5 B6 B7 B8 B9 BA BB BC BD BE BF BG BH BI BJ BK BL BM BN BO BP BQ BR BS BT BU BV BW BX BY BZ C0 C1 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF CG CH CI CJ CK CL CM CN CO CP CQ CR CS CT CU CV CW CX CY CZ D0 D1 D2 D3 D4 D5 D6 D7 D8 D9 DA DB DC DD DE DF DG DH DI DJ DK DL DM DN DO DP DQ DR DS DT DU DV DW DX DZ
需要登录后才可以下载。
登录取消