Highland Terminals
™
W
MTI10-250, MTI14-250, MTI18-250
Male Disconnect, Nylon Fully Insulated, Butted Seam
D
L
Data Sheet
Product
Number
Wire
Range
(AWG)
Mates with Male Tab
Width (W' ) x Thickness
L
W
D
Barrel
Length
Barrel
I.D.
Maximum
Insulation
Diameter
MTI10-250
MTI14-250
MTI18-250
12-10
16-14
22-18
0.250 x 0.032
0.250 x 0.032
0.250 x 0.032
1.05 0.47 0.39
0.95 0.44 0.30
0.95 0.44 0.30
0.25
0.25
0.25
0.150
0.085
0.065
0.250
0.170
0.145
Installation Information
WARNING
UNDERWRITERS
LABORATORIES
STANDARD NO. UL 310
3M FILE NO. E70512
CANADIAN STANDARDS
ASSOCIATION
STANDARD NO. C22.2
NO. 153
3M FILE NO. LR22190
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electrical codes.
UL Listed and CSA Certified for use on stranded copper
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended
3M crimp tool: TH-440, TH-450 (scissor style), or
TR-490 (ratchet style) hand tools.
Specifications
Wire Size:
Barrel Seam:
Max. Voltage Rating:
Max. Temperature Rating:
Max. Current:
Insulator Material:
Terminal Material:
Plating:
See Table Above
Butted
600 V Building Wire
1000 V Signs or
Fixtures (Luminaires)
221˚F (105˚C)
Same as Wire
Nylon
ETP Copper
Tin
Barrel Crimp (Electrical)
Suitable for factory application on steel or brass tabs UL or
CSA.
Suitable for field application on brass tabs, strain relief
required, UL only.
Engineering Specification
Crimp-Type Male Quick-Slide Connectors shall, elec-
trically and mechanically connect permanently to the
prestripped end of a stranded copper wire: and have a
flat rectangular tongue portion for mating to a Female
Disconnect in a separable, reusable manner, forming a
Quick Connect Wiring Connection.
The connector line shall offer tongue variations (size
0.250 x 0.032 or 0.187 x 0.020 per ANSI/NEMA DC-
2) and barrel variations in wire size 22-18 AWG, 16-14
AWG, 12-10 AWG and construction of non-insulated,
vinyl insulated nylon fully insulated etc...
The Quick-Slide Connectors shall have regulatory
agency coverage (UL Listing, CSA Certification). The
tongue shall be marked with the wire range and the
manufacturer’s symbol. ( )
The Nylon Insulated 0.250˝ Male Disconnect shall be
tin plated 0.032˝ thick copper, with a 0.250˝ blade con-
forming to ANSI/NEMA DC-2 dimension and a 0.25˝
long barrel covered by a molded nylon sleeve, color
coded, and sized for a specified (AWG) wire range (22-
18, 16-14, 12-10).
Insulated connectors shall be UL Listed and CSA
Certified for 600 volts maximum, building wire: 1000
volts maximum, signs and fixtures (luminaires). The
connector shall be temperature rated 221˚F (105˚C)
maximum.
Quick Slide Connectors shall be suitable for field or
factory wiring, with a UL Recognized strain relief
required.
3M and Scotchlok are trademarks of 3M
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability.
This product will be free from defects in material and manufacture as of the date of
purchase.
3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
If this product is defective within the warranty period stated above,
your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product.
Except
where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special,
incidental or consequential regardless of the legal theory asserted.
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
http://www.3M.com/elpd