- 本课程为精品课,您可以登录eeworld继续观看:
- FUSES AND CIRCUIT BREAKERS - 230.90(A), Ex. 2
- 继续观看
课时1:APPLYING THE NEC
课时2:ADMINISTRATION AND ENFORCEMENT
课时3:INTRODUCTION AND CHAPTER 1
课时4:CHAPTER 1 ARTICLE 100
课时5:CHAPTER 1 ARTICLE 110
课时6:CHAPTER 2 ARTICLES 200 – 285
课时7:CHAPTER 2 ARTICLES 200 – 285
课时8:CHAPTER 3 ARTICLES 300 – 399
课时9:CHAPTER 4 ARTICLES 400 – 490
课时10:CHAPTER 5 ARTICLES 500 – 590
课时11:CHAPTER 6 ARTICLES 600 – 695
课时12:CHAPTER 7 ARTICLES 700 – 770
课时13:CHAPTER 8 ARTICLES 800 – 840
课时14:CHAPTER 9 TABLES 1 – 12(B)
课时15:PURPOSE OF OSHA
课时16:APPLYING OSHA 1926, SUBPART K
课时17:APPLYING OSHA 1926, SUBPART V
课时18:APPLYING OSHA 1910, SUBPART R
课时19:PURPOSE OF NFPA 70E
课时20:PURPOSE OF NFPA 70B
课时21:PURPOSE OF NFPA 79
课时22:PURPOSE OF THE NESC
课时23:PURPOSE OF THIRD-PARTY CERTIFICATION
课时24:UL WHITE BOOK (Now Electronic)
课时25:APPROVAL
课时26:EXAMINATION, INSTALLATION, AND USE OF EQUIPMENT
课时27:INSTALLING AND MAINTAINING ELECTRICAL EQUIPMENT
课时28:AUTHORITY HAVING JURISDICTION
课时29:Retrofit Kit
课时30:HEART COMPRESSION
课时31:HEAD PROTECTION
课时32:HARD HATS
课时33:FACTOR IN PROTECTION
课时34:HAND AND ARM PROTECTION
课时35:FOOT AND LEG PROTECTION
课时36: (a) OVERALL PROTECTION
课时37:(b) OVERALL PROTECTION
课时38:120 V, SINGLE-PHASE, TWO-WIRE SYSTEMS
课时39:208_120 V, SINGLE-PHASE, THREE-WIRE SYSTEMS
课时40:240_120 V, SINGLE-PHASE, THREE-WIRE SYSTEMS
课时41:208_120 V, THREE-PHASE
课时42:240_120 V, THREE-PHASE
课时43:OPEN-DELTA SYSTEMS
课时44:480_277 V, THREE-PHASE, - FOUR-WIRE SYSTEMS
课时45:SYSTEMS OF 4160 VOLTS
课时46:SYSTEMS OF 13,800 VOLTS
课时47:CONDUCTORS - 720.4
课时48:LAMPHOLDERS - 720.5
课时49:RECEPTACLES - 720.6 AND 720.7
课时50:BATTERIES - 720.9
课时51:CLASS 1 CIRCUIT CLASSIFICATIONS AND POWER SOURCE REQUIREMENTS - 725.41(A) AND (B)
课时52:CONDUCTORS OF DIFFERENT CIRCUITS - 725.48(A) AND (B) AND 300.3(C)(1)
课时53:NUMBER OF CONDUCTORS - 725.51(A), (B), AND (C)
课时54:POWER SOURCES FOR CLASS 2 AND 3 CIRCUITS - 725.121(A), (B), AND (C)
课时55:NONPOWER-LIMITED FIRE ALARM(NPLFA) CIRCUITS - 760.2
课时56:POWER-LIMITED FIRE ALARM (PLFA) CIRCUIT - 760.2 AND 760.154
课时57:INTRINSICALLY SAFE SYSTEM - ARTICLE 100, PART III AND 504.2
课时58:EQUIPMENT - 504.4
课时59:CONTROL DRAWING - 504.10(A) AND ARTICLE 100, Part III
课时60:IN RACEWAYS, CABLE TRAYS, AND CABLES - 504.30(A)(1)
课时61:WITHIN ENCLOSURES - 504.30(A)(2)
课时62:OTHER (NOT IN RACEWAY OR CABLE TRAY SYSTEM) - 504.30(A)(3)
课时63:FROM DIFFERENT INTRINSICALLY SAFE CIRCUIT CONDUCTORS - 504.30(B)(1) AND (B)(2)
课时64:COLOR CODING - 504.80(C)
课时65:GROUNDING - 504.50(A) AND (B)
课时66:BONDING - 504.60(A) AND (B)
课时67:WIRING METHODS AND ENCLOSURES (RECOMMENDED REQUIREMENTS)
课时68:WIRING (RECOMMENDED REQUIREMENTS)
课时69:COLOR CODING (RECOMMENDED REQUIREMENTS)
课时70:LIGHTING SYSTEMS OPERATING AT 30 VOLTS OR LESS - 411.3
课时71:LISTING REQUIRED - 411.4(A) AND (B)
课时72:SPECIFIC LOCATION REQUIREMENTS - 411.5(A) AND (B)
课时73:SECONDARY CIRCUITS - 411.6(A) THRU (C)
课时74:BRANCH CIRCUIT - 411.7
课时75:SPACES ABOUT ELECTRICAL EQUIPMENT - 110.26(A)(1) THRU (A)(4)
课时76:DEPTH OF WORKING SPACE - 110.26(A)(1), AND TABLE 110.26(A)(1), CONDITION 1
课时77:DEPTH OF WORKING SPACE - 110.26(A)(1) AND TABLE 110.26(A)(1), CONDITION 2
课时78:DEPTH OF WORKING SPACE - 110.26(A)(1) AND TABLE 110.26(A)(1), CONDITION 2
课时79:DEPTH OF WORKING SPACE - 110.26(A)(1) AND TABLE 110.26(A)(1), CONDITION 3
课时80:EXISTING BUILDINGS - 110.26(A)(1)(c)
课时81:HEIGHT OF WORKING SPACE - 110.26(A)(3)
课时82:DEDICATED ELECTRICAL SPACE - 110.26(E)(1)(a)
课时83:ENTRANCE TO AND EGRESS FROM WORKING SPACE - 110.26(C)(1) AND (C)(2)
课时84:LARGE EQUIPMENT - 110.26(C)(2)
课时85:ILLUMINATION - 110.26(D)
课时86:DEDICATED ELECTRICAL SPACE - 110.26(E)(1)(a)
课时87:CLEAR SPACES - 110.26(B)
课时88:FOREIGN SYSTEMS - 110.26(E)(1)(b)
课时89:LIVE PARTS GUARDED AGAINST ACCIDENTAL CONTACT - 110.27(A)
课时90:LIVE PARTS GUARDED AGAINST ACCIDENTAL CONTACT - 110.27(A)
课时91:PREVENT PHYSICAL DAMAGE - 110.27(B)
课时92:WARNING SIGNS - 110.27(C)
课时93:ENTRANCE TO ENCLOSURES AND ACCESS TO WORKING SPACE (OVER 1000 V) - 110.33
课时94:ACCESS - 110.33(B)
课时95:ENCLOSURE FOR ELECTRICAL INSTALLATIONS - 110.31
课时96:ELECTRICAL VAULTS - 110.31(A)
课时97:INDOOR INSTALLATIONS - 110.31(B)
课时98:OUTDOOR INSTALLATIONS - 110.31(C)
课时99:ENCLOSED EQUIPMENT ACCESSIBLE TO UNQUALIFIED PERSONS - 110.31(D)
课时100:WORKSPACE ABOUT EQUIPMENT - 110.32
课时101:ENTRANCE TO ENCLOSURES AND ACCESS TO WORKING SPACE - 110.33
课时102:PERSONNEL DOORS - 110.33(A)(3)
课时103:ACCESS - 110.33(B)
课时104:ILLUMINATION - 110.34(D)
课时105:ELEVATION OF UNGUARDED LIVE PARTS - 110.34(E) AND TABLE 110.34(E)
课时106:IDENTIFICATION OF DISCONNECTING MEANS - 110.22
课时107:ARC-FLASH HAZARD WARNING - 110.16(B), INs 1 AND 3
课时108:ARC-FLASH HAZARD WARNING - 110.16(B), INs 1 AND 3
课时109:AVAILABLE FAULT CURRENT - 110.24(A) AND (B)
课时110:FIELD-APPLIED MARKINGS - 110.21(B)
课时111:FIELD MARKING - 110.24(A)
课时112:FIRE PUMPS - 230.2(A)(1)
课时113:EMERGENCY SYSTEMS - 230.2(A)(2)
课时114:SPECIAL OCCUPANCIES - 230.2(B)(1)
课时115:DIFFERENT CHARACTERISTICS - 230.2(D)
课时116:BUILDINGS COVERING A LARGE AREA - 230.2(B)(2)
课时117:CAPACITY REQUIREMENTS - 230.2(C)(1) AND (C)(2)
课时118:UNDERGROUND SETS OF CONDUCTORS - 230.2
课时119:CONDUCTORS CONSIDERED OUTSIDE THE BUILDING - 230.6
课时120:OTHER CONDUCTORS IN RACEWAY OR CABLE - 230.7
课时121:(a) CLEARANCE FROM BUILDING OPENINGS - 230.9(C)
课时122: (b) CLEARANCE FROM BUILDING OPENINGS - 230.9(C)
课时123:VEGETATION AS SUPPORT - 230.10
课时124:(a) INSULATION OR COVERING - 230.22
课时125:(b) INSULATION OR COVERING - 230.22 Ex
课时126: (a) ROOFS SUBJECT TO PEDESTRIAN OR VEHICULAR TRAFFIC - 230.24(A), Ex. 1
课时127:(b) VOLTAGE NOT EXCEEDING 300 VOLTS - 230.24(A), Ex. 2
课时128:(c) OVERHANGING PORTION OF THE ROOF - 230.24(A), Ex. 3
课时129:VERTICAL CLEARANCE FOR OVERHEAD SERVICE CONDUCTORS - 230.24(B)
课时130:(a) MEANS OF ATTACHMENT - 230.27
课时131:(b) MEANS OF ATTACHMENT - 230.27
课时132:(c) MEANS OF ATTACHMENT - 230.27
课时133:UNDERGROUND SERVICE CONDUCTORS - ARTICLE 230, PART III
课时134:6-18
课时135:SIZE AND RATING - 230.31(A) AND (B)
课时136:SIZE AND RATING - 230.42(A) THRU (C)
课时137:SPLICED AND TAPPED CONDUCTORS - 230.46
课时138:SPLICED AND TAPPED CONDUCTORS - 230.46
课时139:SPLICED AND TAPPED CONDUCTORS - 230.46
课时140:SPLICED AND TAPPED CONDUCTORS - 230.46
课时141:SPLICED AND TAPPED CONDUCTORS - 230.46
课时142:SERVICE-ENTRANCE CABLES - 230.51(A)
课时143:INDIVIDUAL OPEN CONDUCTORS - 230.51(C)
课时144:INDIVIDUAL CONDUCTORS ENTERING BUILDINGS OR OTHER STRUCTURES - 230.52
课时145:RACEWAYS TO DRAIN - 230.53
课时146:SERVICE-ENTRANCE CABLES EQUIPPED WITH SERVICE HEAD OR GOOSENECK - 230.54(B)
课时147:(a) SERVICE HEADS AND GOOSENECKS ABOVE SERVICE-DROP OR OVERHEAD SERVICE ATTACHMENT - 230.54(C)
课时148:(b) ERVICE HEADS AND GOOSENECKS ABOVE SERVICE-DROP OR OVERHEAD SERVICE ATTACHMENT - 230.54(C)
课时149:SERVICE CONDUCTOR WITH THE HIGHER VOLTAGE-TO-GROUND - 230.56
课时150:(a) AVAILABLE SHORT-CIRCUIT CURRENT - 110.9, 110.10, AND 230.24
课时151:(b) AVAILABLE SHORT-CIRCUIT CURRENT - 110.9, 110.10, AND 230.24
课时152:(c) AVAILABLE SHORT-CIRCUIT CURRENT - 110.9, 110.10, AND 230.24
课时153:LOCATION - 230.70(A)
课时154:MAXIMUM NUMBER OF DISCONNECTS - 230.71(A) AND (B)(1) THRU (B)(4)
课时155:GROUPING OF DISCONNECTS - 230.72
课时156:SIMULTANEOUS OPENING OF POLES - 230.74
课时157:DISCONNECTION OF GROUNDED CONDUCTOR - 230.75
课时158:TRANSFER EQUIPMENT RATED AS SERVICE EQUIPMENT
课时159:NUMBER OF SUPPLIES - 225.30
课时160:MOTORS - 230.90(A), Ex. 1
课时161:FUSES AND CIRCUIT BREAKERS - 230.90(A), Ex. 2
课时162:SIX CIRCUIT BREAKERS OR SIX SETS OF FUSES - 230.90(A), Ex. 3
课时163:FIRE PUMPS - 230.90(A), Ex. 4
课时164:NEC 310.12(A) THRU (D) TO AMPACITY TABLES OF 0 – 2000 VOLTS - 230.90(A), Ex. 5
课时165:UNDER SINGLE MANAGEMENT - 225.32, Ex. 1
课时166:SERVICE AND FEEDER OVERCURRENT DEVICES - 240.24(B)(1)
课时167:PROTECTION OF SPECIFIC CIRCUITS - 230.93
课时168:(a) GROUND-FAULT PROTECTION OF EQUIPMENT - 230.95
课时169: (b) GROUND-FAULT PROTECTION OF EQUIPMENT - 230.95
课时170:SERVICE POINT - ARTICLE 100
课时171:CLASSIFICATION - ARTICLE 100, PART II
课时172:LOCKED ROOMS OR ENCLOSURES - 110.34(C)
课时173:ISOLATING SWITCHES - 230.204
课时174:(a) PROTECTION REQUIREMENTS - 230.208
课时175:(b) PROTECTION REQUIREMENTS - 230.208
课时176:OVERCURRENT PROTECTION AND REQUIREMENTS FOR FEEDER CONDUCTORS - 240.100 AND 240.101
课时177:ELECTRICAL SERVICE AREAS - 210.63(B)(1)
课程介绍共计177课时,11小时17分30秒
Everyone from engineers, electrical contractors, inspectors, electricians, and instructors of the Code have anticipated the arrival of this book. The large workbook format allows a masterful blending of valuable Design Tips, NEC Loops, Examples, Quick Calcs, and effective illustrations with authoritative Code references. Because of the abundant amount of detailed information included, it is the most comprehensive design book of its kind.
Stallcup’s® Designing Electrical Systems explains the purpose of the National Electrical Code (NEC) and more particularly, its use as it applies to the design and installation of electrical wiring systems and equipment.
While the substance of design is found in the National Electrical Code, the art of the design is found in the applicability of that same National Electrical Code. With the advancement of today’s technology and ever-increasing liabilities, effective electrical design must now, more than ever, consider the use of certified products, energy conservation, economy vs. quality, anticipated load growth, local codes, special applications of electrical equipment, and the use and interpretation of the National Fire Protection Association (NFPA) and the Institute of Electrical and Electronics Engineers (IEEE) standards that relate to special areas, etc. For better understanding and interpretation of these advancements, considerable effort has been made by the author to condense the more complicated rules pertaining to the design, installation, and selection of wiring methods and equipment.
For the convenience of the reader, Designing Electrical Systems not only contains discussions and explanations of Code rules, but also includes detailed illustrations and sample calculations that will help tremendously in understanding and becoming proficient in the application of the National Electrical Code. Designing Electrical Systems also points out common industry problems and shows in detail the proper procedures and techniques to use in order to ensure proper code compliance. Design Tips, Calculation Tips, and guidelines for "rule of thumb" methods for instances where a fast and approximate design answer is needed are also provided.
In order for the reader to measure his or her design skills or to prepare for a maintenance, journeyman or master electrician examination or for inspector certification, an ample number of quizzes, tests, and final examinations have been included.
With the wealth of information found in this book, it will make a valuable addition to the library of any consultant, serve as an excellent reference to the seasoned professional, and also provide valuable introductory material to the beginner.